A LONG-RANGE, IMPLANTABLE TELEMETRY SYSTEM FOR CHRONIC NEURAL RECORDING

被引:0
|
作者
Seydnejad, Saeid Reza [1 ]
Olumi, Mohammad Mahdi [2 ]
Mosayebi-Samani, Mohsen [1 ]
Sheibani, Vahid [3 ]
机构
[1] Shahid Bahonar Univ Kerman, Dept Elect Engn, Kerman 7616914111, Iran
[2] Shahid Bahonar Univ Kerman, Fac Vet Med, Kerman 7616914111, Iran
[3] Kerman Univ Med Sci, Neurosci Res Ctr, Kerman, Iran
关键词
biomedical sensors; implantable devices; inductive powering; neuroprosthetics; telemetry; WIRELESS TRANSMISSION; DESIGN;
D O I
10.1080/10739149.2012.710885
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Long-term neurophysiological studies of unanesthetized and freely moving animals require an implantable miniaturized telemetry system that can acquire and transmit neural firing patterns or other relevant physiological signals directly from inside the body. In this article, the design and in-vivo results of a long-range, chronic, implantable bio-telemetry system are presented. This system has three main features: wireless inductive powering capability with implanted rechargeable battery for long-term biosignal measurement, ultra-low power wireless stand-by mechanism, and long range data transmission (up to 70m) with a variable gain bio-amplifier. The design is based on commercial, off-the-shelf components and provides a solid framework for implementing similar systems by other research groups. The in-vitro experiment of our system was performed by submerging the internal module of the system in a saline container and applying a wide range of signals with different amplitudes and frequencies to verify its sensitivity and fidelity in capturing low-amplitude, large-bandwidth biosignals. In-vivo experiment of the system was performed by implanting the internal module in the inguinal region of a dog and inserting the measuring electrodes into its quadriceps femoris muscle. The system successfully recorded intramuscular activity in which motor unit activity could easily be distinguished. The module was in place for three months, after which it was removed from the animal and showed no sign of damage or corrupting tissue growth.
引用
收藏
页码:1 / 17
页数:17
相关论文
共 50 条
  • [21] ABERRANT LONG-RANGE NEURAL SYNCHRONIZATION IN SCHIZOPHRENIA
    Hayrynen, Lauren K.
    Hamm, Jordan P.
    Ethridge, Lauren E.
    Tamminga, Carol A.
    Sweeney, John A.
    Pearlson, Godfrey D.
    Keshavan, Matcheri S.
    Clementz, Brett A.
    PSYCHOPHYSIOLOGY, 2014, 51 : S50 - S50
  • [22] A MULTICHANNEL IMPLANTABLE TELEMETRY SYSTEM
    FRYER, TB
    SANDLER, H
    DATNOW, B
    MEDICAL RESEARCH ENGINEERING, 1969, 8 (02) : 9 - &
  • [23] Telemetry system for recording neural activities in pigs-Comparison with cable system
    Saito, Toshiyuki
    Fujiwara, Sei-etsu
    Hisakura, Katsuji
    Ohkohchi, Nobuhiro
    Akema, Tatsuo
    Sasamori, Soichiro
    Konno, Kenjiro
    Kobayashi, Eiji
    Yamaguchi, Takashi
    BRAIN RESEARCH BULLETIN, 2011, 84 (01) : 103 - 109
  • [24] Verification system based on long-range iris and Graph Siamese Neural Networks
    Zola, Francesco
    Fernandez-Carrasco, Jose Alvaro
    Lukas Bruse, Jan
    Galar, Mikel
    Geradts, Zeno
    PROCEEDINGS OF 2022 THE 3RD EUROPEAN SYMPOSIUM ON SOFTWARE ENGINEERING, ESSE 2022, 2022, : 80 - 88
  • [25] SYSTEM OF OPTIMAL LONG-RANGE PLANNING
    BARANOV, EF
    DANILOVD.VI
    ZAVELSKI.MG
    MATEKON, 1972, 9 (02): : 3 - 33
  • [26] SPINODALS IN A LONG-RANGE INTERACTION SYSTEM
    HERRMANN, DW
    KLEIN, W
    STAUFFER, D
    PHYSICAL REVIEW LETTERS, 1982, 49 (17) : 1262 - 1264
  • [27] PROGNOSTIC SYSTEM OF LONG-RANGE PLANNING
    SZUCS, A
    ELELMEZESI IPAR, 1980, 34 (05): : 192 - 195
  • [28] THE NAVAGLOBE LONG-RANGE NAVIGATION SYSTEM
    CLARK, CT
    COLIN, RI
    DISHAL, M
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1954, 42 (03): : 607 - 608
  • [29] Long-Range Magnetic Tracking System
    Vcelak, Jan
    Ripka, Pavel
    Zikmund, Ales
    IEEE SENSORS JOURNAL, 2015, 15 (01) : 491 - 496
  • [30] LONG-RANGE MICROSCOPE CONDENSING SYSTEM
    HIRSCHBERG, JG
    APPLIED OPTICS, 1990, 29 (10): : 1409 - 1410