Pulsed-light inactivation of pathogenic and spoilage bacteria on cheese surface

被引:34
|
作者
Proulx, J. [1 ]
Hsu, L. C. [1 ]
Miller, B. M. [1 ]
Sullivan, G. [1 ]
Paradis, K. [2 ]
Moraru, C. I. [1 ]
机构
[1] Cornell Univ, Dept Food Sci, Ithaca, NY 14853 USA
[2] McGill Univ, Dept Food Sci & Agr Chem, Ste Anne De Bellevue, PQ H9X 3V9, Canada
基金
美国国家科学基金会;
关键词
pulsed light; surface decontamination; spoilage and pathogenic bacteria; Cheddar cheese; process cheese; ESCHERICHIA-COLI; LISTERIA-INNOCUA; PSEUDOMONAS-FLUORESCENS; FOOD DECONTAMINATION; PASTEURIZED MILK; APPLE JUICE; TECHNOLOGY; OUTBREAK;
D O I
10.3168/jds.2015-9410
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Cheese products are susceptible to postprocessing cross-contamination by bacterial surface contamination during slicing, handling, or packaging, which can lead to food safety issues and significant losses due to spoilage. This study examined the effectiveness of pulsed-light (PL) treatment on the inactivation of the spoilage microorganism Pseudomonas fluorescens, the nonenteroliemorrhagic Escherichia coli ATCC 25922 (nonpathogenic surrogate of Escherichia coli O157:H7), and Listeria innocua (nonpathogenic surrogate of Listeria monocytogenes) on cheese surface. The effects of inoculum level and cheese surface topography and the presence of clear polyethylene packaging were evaluated in a full factorial experimental design. The challenge microorganism's were grown to early stationary phase and subsequently diluted to reach initial inoculum levels of either 5 or 7 log cfu/slice. White Cheddar and process cheeses were cut into 2.5 x 5 cm slices, which were spot-inoculated with 100 mu L of bacterial suspension. Inoculated cheese samples were exposed to PL doses of 1.02 to 12.29 J/cm(2). Recovered survivors were enumerated by standard plate counting or the most probable number technique, as appropriate. The PL treatments were performed in triplicate and data were analyzed using a general linear model. Listeria innocua was the least sensitive to PL treatment, with a maximum inactivation level of 3.37 +/- 0.2 log, followed by P. fluorescens, with a maximum inactivation of 3.74 +/- 0.8 log. Escherichia coli was the most sensitive to PL, with a maximum reduction of 5.41 +/- 0.1 log. All PL inactivation curves were nonlinear, and inactivation reached a plateau after 3 pulses (3.07 J/cm(2)). The PL treatments through UV-transparent packaging and without packaging consistently resulted in similar inactivation levels. This study demonstrates that PL has strong potential for decontamination of the cheese surface.
引用
收藏
页码:5890 / 5898
页数:9
相关论文
共 50 条
  • [21] BIOLUMINESCENCE DISPLAYS INDUCED BY PULSED-LIGHT
    LAPOTA, D
    LOSEE, JR
    GEIGER, ML
    LIMNOLOGY AND OCEANOGRAPHY, 1986, 31 (04) : 887 - 889
  • [22] Ultrasound assisted thermal inactivation of spores in foods: Pathogenic and spoilage bacteria, molds and yeasts
    Evelyn
    Silva, Filipa V. M.
    TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2020, 105 : 402 - 415
  • [23] PULSED-LIGHT TREATMENT OF FOOD AND PACKAGING
    DUNN, J
    OTT, T
    CLARK, W
    FOOD TECHNOLOGY, 1995, 49 (09) : 95 - 98
  • [24] Pulsed-light treatment of food and packaging
    PurePulse Technologies, Inc, San Diego, United States
    Food Technol, 9 (95-98):
  • [25] Cell surface hydrophobicity and attachment of pathogenic and spoilage bacteria to meat surfaces
    Benito, Y
    Pin, C
    Marin, ML
    Garcia, ML
    Selgas, MD
    Casas, C
    MEAT SCIENCE, 1997, 45 (04) : 419 - 425
  • [26] Effect of sublethal temperatures on pulsed light inactivation of bacteria
    Hilton, S. T.
    de Moraes, J. O.
    Moraru, C. I.
    INNOVATIVE FOOD SCIENCE & EMERGING TECHNOLOGIES, 2017, 39 : 49 - 54
  • [27] Chicken fillets subjected to UV-C and pulsed UV light: Reduction of pathogenic and spoilage bacteria, and changes in sensory quality
    McLeod, Anette
    Liland, Kristian Hovde
    Haugen, John-Erik
    Sorheim, Oddvin
    Myhrer, Kristine S.
    Holck, Askild L.
    JOURNAL OF FOOD SAFETY, 2018, 38 (01)
  • [28] AEROSOL HEATING AND VAPORIZATION BY PULSED-LIGHT BEAMS
    ARMSTRONG, RL
    APPLIED OPTICS, 1984, 23 (01): : 148 - 155
  • [29] OPTOELECTRONIC UNIT FOR THE INVESTIGATION OF PULSED-LIGHT SIGNALS
    AVERYANOV, GA
    VORONOV, AS
    CHISTYAKOV, SN
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1978, 21 (04) : 1080 - 1081
  • [30] PROGRAMMED COMMAND UNIT FOR PULSED-LIGHT SOURCE
    MEYER, JJ
    AUBARD, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1977, 48 (06): : 695 - 696