Light propagation in tissue during fluorescence spectroscopy with single-fiber probes

被引:45
作者
Pfefer, TJ [1 ]
Schomacker, KT
Ediger, MN
Nishioka, NS
机构
[1] US FDA, Ctr Devices & Radiol Hlth, Rockville, MD 20857 USA
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Wellman Labs Photomed, Boston, MA 02114 USA
关键词
computational modeling; fiberoptic; fluorescence spectroscopy; Monte Carlo;
D O I
10.1109/2944.983306
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Fluorescence spectroscopy systems designed for clinical use commonly employ fiberoptic probes to deliver excitation light to a tissue site and collect remitted fluorescence. Although a wide variety of probes have been implemented, there is little known about the influence of probe design on light propagation and the origin of detected signals. In this study, we examined the effect of optical fiber diameter, probe-tissue spacing and numerical aperture on light propagation during fluorescence spectroscopy with a single-fiber probe. A Monte Carlo model was used to simulate light transport in tissue. Two distinct sets of excitation-emission wavelength pairs were studied (337/450 nm and 400/630 nm). Simulation results indicated that increasing fiber diameter or fiber-tissue spacing increased the mean excitation-emission photon pair pathlength and produced a transition from high selectivity for superficial fluorophores to a more homogeneous probing with depth. Increasing numerical aperture caused an increase in signal intensity, but axial emission profiles and pathlengths were not significantly affected for numerical aperture values less than 0.8. Tissue optics mechanisms and implications for probe design are discussed. This study indicates that single-fiber probe parameters can strongly affect fluorescence detection and should be considered in the design of optical diagnostic devices.
引用
收藏
页码:1004 / 1012
页数:9
相关论文
共 45 条
[1]   Influence of the emission-reception geometry in laser-induced fluorescence spectra from turbid media [J].
Avrillier, S ;
Tinet, E ;
Ettori, D ;
Tualle, JM ;
Gelebart, B .
APPLIED OPTICS, 1998, 37 (13) :2781-2787
[2]   Clinical determination of tissue optical properties by endoscopic spatially resolved reflectometry [J].
Bays, R ;
Wagnieres, G ;
Robert, D ;
Braichotte, D ;
Savary, JF ;
Monnier, P ;
vandenBergh, H .
APPLIED OPTICS, 1996, 35 (10) :1756-1766
[3]  
BRAICHOTTE D, 1994, P SOC PHOTO-OPT INS, V2081, P62, DOI 10.1117/12.166811
[4]  
Braichotte DR, 1996, LASER SURG MED, V19, P340, DOI 10.1002/(SICI)1096-9101(1996)19:3<340::AID-LSM10>3.0.CO
[5]  
2-8
[6]  
BRAICHOTTE DR, 1995, CANCER, V75, P2768, DOI 10.1002/1097-0142(19950601)75:11<2768::AID-CNCR2820751122>3.0.CO
[7]  
2-I
[8]   Detection of dysplasia at colonoscopy using laser-induced fluorescence: A blinded study [J].
Cothren, RM ;
Sivak, MV ;
VanDam, J ;
Petras, RE ;
Fitzmaurice, M ;
Crawford, JM ;
Wu, J ;
Brennan, JF ;
Rava, RP ;
Manoharan, R ;
Feld, MS .
GASTROINTESTINAL ENDOSCOPY, 1996, 44 (02) :168-176
[9]   Fluorescence lifetime imaging of experimental tumors in hematoporphyrin derivative-sensitized mice [J].
Cubeddu, R ;
Canti, G ;
Pifferi, A ;
Taroni, P ;
Valentini, G .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1997, 66 (02) :229-236
[10]   Confocal fluorescence microscopy, microspectrofluorimetry and modeling studies of laser induced fluorescence endoscopy (LIFE) of human colon tissue [J].
DaCosta, RS ;
Lilge, L ;
Kost, J ;
Cirroco, M ;
Hassaram, S ;
Marcon, N ;
Wilson, BC .
LASER-TISSUE INTERACTION VIII, PROCEEDINGS OF, 1997, 2975 :98-107