Through the years with on-a-chip gas chromatography: a review

被引:68
作者
Haghighi, F. [1 ]
Talebpour, Z. [1 ]
Sanati-Nezhad, A. [2 ]
机构
[1] Alzahra Univ, Fac Phys & Chem, Dept Chem, Chromatog & Separat Lab, Tehran, Iran
[2] Univ Calgary, Dept Mech & Mfg Engn, BioMEMS & Bioinspired Microfluid Lab, Calgary, AB T2N 1N4, Canada
关键词
THERMAL-CONDUCTIVITY DETECTOR; FLAME IONIZATION DETECTOR; PROTECTED GOLD NANOPARTICLES; SILICON MICROFABRICATED COLUMNS; VOLATILE ORGANIC-COMPOUNDS; CHEMICAL-ANALYSIS SYSTEMS; MU-GC; STATIONARY PHASES; MICROFLUIDIC DEVICES; HIGH-PERFORMANCE;
D O I
10.1039/c5lc00283d
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In recent years, the need for measurement and detection of samples in situ or with very small volume and low concentration (low and sub-parts per billion) is a cause for miniaturizing systems via microelectromechanical system (MEMS) technology. Gas chromatography (GC) is a common technique that is widely used for separating and measuring semi-volatile and volatile compounds. Conventional GCs are bulky and cannot be used for in situ analysis, hence in the past decades many studies have been reported with the aim of designing and developing chip-based GC. The focus of this review is to follow and investigate the development and the achievements in the field of chip-based GC and its components from the beginning up to the present.
引用
收藏
页码:2559 / 2575
页数:17
相关论文
共 154 条
[1]  
Adams TM, 2010, INTRO MEMS, P95
[2]   High-performance temperature-programmed microfabricated gas chromatography columns [J].
Agah, M ;
Potkay, JA ;
Lambertus, G ;
Sacks, R ;
Wise, KD .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2005, 14 (05) :1039-1050
[3]   Low-mass PECVD oxynitride gas chromatographic columns [J].
Agah, Masoud ;
Wise, Kensall D. .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2007, 16 (04) :853-860
[4]   High-speed MEMS-based gas chromatography [J].
Agah, Masoud ;
Lambertus, Gordon Randall ;
Sacks, Richard ;
Wise, Kensall .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2006, 15 (05) :1371-1378
[5]   Analysis of breakthrough dynamics in rectangular channels of arbitrary aspect ratio [J].
Ahn, H ;
Brandani, S .
AICHE JOURNAL, 2005, 51 (07) :1980-1990
[6]   Hydrodynamic dispersion in shallow mirochannels: the effect of cross-sectional shape [J].
Ajdari, A ;
Bontoux, N ;
Stone, HA .
ANALYTICAL CHEMISTRY, 2006, 78 (02) :387-392
[7]   Improved performance of micro-fabricated preconcentrators using silica nanoparticles as a surface template [J].
Akbar, Muhammad ;
Wang, Dong ;
Goodman, Ryan ;
Hoover, Ashley ;
Rice, Gary ;
Heflin, James R. ;
Agah, Masoud .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1322 :1-7
[8]   MEMS-based multi-inlet/outlet preconcentrator coated by inkjet printing of polymer adsorbents [J].
Alfeeli, Bassam ;
Cho, Daniel ;
Ashraf-Khorassani, Mehdi ;
Taylor, Larry T. ;
Agah, Masoud .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 133 (01) :24-32
[9]   Evaluation of Tenax TA thin films as adsorbent material for micro preconcentration applications [J].
Alfeeli, Bassam ;
Taylor, Larry T. ;
Agah, Masoud .
MICROCHEMICAL JOURNAL, 2010, 95 (02) :259-267
[10]   MEMS-based semi-packed gas chromatography columns [J].
Ali, Syed ;
Ashraf-Khorassani, Mehdi ;
Taylor, Larry T. ;
Agah, Masoud .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 141 (01) :309-315