Semiactive control strategy for a phase II smart base isolated benchmark building

被引:17
|
作者
Chang, Chia-Ming [1 ]
Park, Kyu-Sik [2 ]
Mullenix, Alan [1 ]
Spencer, Billie F., Jr. [1 ]
机构
[1] Univ Illinois, Dept Civil & Environm Engn, Urbana, IL 61801 USA
[2] RIST, Steel Struct Res Lab, Hwaseong 445813, Gyeonggi Do, South Korea
来源
STRUCTURAL CONTROL & HEALTH MONITORING | 2008年 / 15卷 / 05期
关键词
benchmark isolated building; magnetorheological fluid damper; direct output feedback control; seismic response control; simplified nonlinear control strategies;
D O I
10.1002/stc.269
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a semiactive control strategy for the seismic protection pf the phase II smart base isolated benchmark building subjected to near-fault earthquakes. MAgnetorheological (MR) fluid dampers controlled by an optimal direct output feedback control algorithm with a voltage generator are used as semiactive control devices. The benchmark building is an eight-story base isolated building, and the superstructure is considered to be a linear elastic system with lateral-torsional behavior. To reduce the energy transmitted to the structure from the ground, a combination of linear and nonlinerar bearings is installed at the base of the structure. It is difficult to design the controller for this benchmark problem because of the nonlinear behavior of the isolation members. Linear control theory is frequently applied to nonlinear structures because there are no appropriate and well-defined control theories that can consider general types of nonlinearities. Therefore, to improve control performance, the nonlinearities of the isolation members are considered indirectly with the linear control theory during the design process of the controllers for the MR dampers. Numerical simulation results under various earthquake inputs show that the proposed contrl strategy is effective in reducing the responses of the isolation members as well as the superstructure. Therefore, the proposed control system could be used as an improved control strategy for base isolated buildings subjected to near-fault earthquakes. Copyright (c) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:673 / 696
页数:24
相关论文
共 50 条
  • [21] Smart base-isolated benchmark building Part III: A sample controller for bilinear isolation
    Erkus, Baris
    Johnson, Erik A.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 605 - 625
  • [22] Semiactive control of the 20-story benchmark building with piezoelectric friction dampers
    Chen, GD
    Chen, CQ
    JOURNAL OF ENGINEERING MECHANICS, 2004, 130 (04) : 393 - 400
  • [23] Seismic protection of base-isolated building with nonlinear isolation system using smart passive control strategy
    Choi, Kang-Min
    Jung, Hyung-Jo
    Lee, Heon-Jae
    Cho, Sang-Won
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (05): : 785 - 796
  • [24] Control effect for 20-story benchmark building using passive or semiactive device
    Fukukita, A
    Saito, T
    Shiba, K
    JOURNAL OF ENGINEERING MECHANICS, 2004, 130 (04) : 430 - 436
  • [25] Effectiveness and adaptability analysis of smart base isolated benchmark model with pseudo-negative stiffness control
    Gong, Wei
    Xiong, Shishu
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2015, 43 (08): : 7 - 11
  • [26] Ground motion pulse-based active control of a linear base-isolated benchmark building
    Agrawal, AK
    Xu, Z
    He, WL
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 792 - 808
  • [27] The Computational Analysis and Evaluation on the Seismic Response of Base Isolated Benchmark Building
    Li, Xiangzhen
    Li, Bing
    Fu, Huanchang
    Xiang, Weiming
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 2387 - +
  • [28] Seismic control of a nonlinear benchmark building using smart dampers
    Yoshida, O
    Dyke, SJ
    JOURNAL OF ENGINEERING MECHANICS, 2004, 130 (04) : 386 - 392
  • [29] Control of a Seismically Excited Benchmark Building Using Linear Matrix Inequality-Based Semiactive Nonlinear Fuzzy Control
    Kim, Yeesock
    Langari, Reza
    Hurlebaus, Stefan
    JOURNAL OF STRUCTURAL ENGINEERING, 2010, 136 (08) : 1023 - 1026
  • [30] Application of a high-pressure gas semi-active resettable damper to the benchmark smart base-isolated building
    Leavitt, John
    Bobrow, James E.
    Jabbari, Faryar
    Yang, Jann N.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 748 - 757