Semiactive control strategy for a phase II smart base isolated benchmark building

被引:17
作者
Chang, Chia-Ming [1 ]
Park, Kyu-Sik [2 ]
Mullenix, Alan [1 ]
Spencer, Billie F., Jr. [1 ]
机构
[1] Univ Illinois, Dept Civil & Environm Engn, Urbana, IL 61801 USA
[2] RIST, Steel Struct Res Lab, Hwaseong 445813, Gyeonggi Do, South Korea
关键词
benchmark isolated building; magnetorheological fluid damper; direct output feedback control; seismic response control; simplified nonlinear control strategies;
D O I
10.1002/stc.269
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a semiactive control strategy for the seismic protection pf the phase II smart base isolated benchmark building subjected to near-fault earthquakes. MAgnetorheological (MR) fluid dampers controlled by an optimal direct output feedback control algorithm with a voltage generator are used as semiactive control devices. The benchmark building is an eight-story base isolated building, and the superstructure is considered to be a linear elastic system with lateral-torsional behavior. To reduce the energy transmitted to the structure from the ground, a combination of linear and nonlinerar bearings is installed at the base of the structure. It is difficult to design the controller for this benchmark problem because of the nonlinear behavior of the isolation members. Linear control theory is frequently applied to nonlinear structures because there are no appropriate and well-defined control theories that can consider general types of nonlinearities. Therefore, to improve control performance, the nonlinearities of the isolation members are considered indirectly with the linear control theory during the design process of the controllers for the MR dampers. Numerical simulation results under various earthquake inputs show that the proposed contrl strategy is effective in reducing the responses of the isolation members as well as the superstructure. Therefore, the proposed control system could be used as an improved control strategy for base isolated buildings subjected to near-fault earthquakes. Copyright (c) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:673 / 696
页数:24
相关论文
共 18 条
[1]  
[Anonymous], 2000, EARTHQ SPECTRA
[2]  
Asher JW, 1996, STRUCT DES TALL BUIL, V5, P265, DOI 10.1002/(SICI)1099-1794(199612)5:4<265::AID-TAL77>3.0.CO
[3]  
2-X
[4]   Constant-gain linear feedback control of piecewise linear structural systems via nonlinear normal modes [J].
Butcher, EA ;
Lu, R .
JOURNAL OF VIBRATION AND CONTROL, 2004, 10 (10) :1535-1558
[5]  
CHANG CM, 2006, J INTELLIGENT MAT SY
[6]   OPTIMAL DIRECT OUTPUT-FEEDBACK OF STRUCTURAL CONTROL [J].
CHUNG, LL ;
LIN, CC ;
CHU, SY .
JOURNAL OF ENGINEERING MECHANICS, 1993, 119 (11) :2157-2173
[7]   Smart base-isolated benchmark building Part III: A sample controller for bilinear isolation [J].
Erkus, Baris ;
Johnson, Erik A. .
STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3) :605-625
[8]  
HALL JF, 1995, EARTHQUAKE SPECTR SC, V11, P1
[9]  
*ICBO, 1997, INT C BUILD OFF UN B, V2, pCH16
[10]   Experimental verification of a wireless sensing and control system for structural control using MR dampers [J].
Loh, Chin-Hsiung ;
Lynch, Jerome P. ;
Lu, Kung-Chun ;
Wang, Yang ;
Chang, Chia-Ming ;
Lin, Pei-Yang ;
Yeh, Ting-Hei .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2007, 36 (10) :1303-1328