Semiactive control strategy for a phase II smart base isolated benchmark building

被引:17
|
作者
Chang, Chia-Ming [1 ]
Park, Kyu-Sik [2 ]
Mullenix, Alan [1 ]
Spencer, Billie F., Jr. [1 ]
机构
[1] Univ Illinois, Dept Civil & Environm Engn, Urbana, IL 61801 USA
[2] RIST, Steel Struct Res Lab, Hwaseong 445813, Gyeonggi Do, South Korea
来源
关键词
benchmark isolated building; magnetorheological fluid damper; direct output feedback control; seismic response control; simplified nonlinear control strategies;
D O I
10.1002/stc.269
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a semiactive control strategy for the seismic protection pf the phase II smart base isolated benchmark building subjected to near-fault earthquakes. MAgnetorheological (MR) fluid dampers controlled by an optimal direct output feedback control algorithm with a voltage generator are used as semiactive control devices. The benchmark building is an eight-story base isolated building, and the superstructure is considered to be a linear elastic system with lateral-torsional behavior. To reduce the energy transmitted to the structure from the ground, a combination of linear and nonlinerar bearings is installed at the base of the structure. It is difficult to design the controller for this benchmark problem because of the nonlinear behavior of the isolation members. Linear control theory is frequently applied to nonlinear structures because there are no appropriate and well-defined control theories that can consider general types of nonlinearities. Therefore, to improve control performance, the nonlinearities of the isolation members are considered indirectly with the linear control theory during the design process of the controllers for the MR dampers. Numerical simulation results under various earthquake inputs show that the proposed contrl strategy is effective in reducing the responses of the isolation members as well as the superstructure. Therefore, the proposed control system could be used as an improved control strategy for base isolated buildings subjected to near-fault earthquakes. Copyright (c) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:673 / 696
页数:24
相关论文
共 50 条
  • [1] Structural control benchmark problem: Phase II - nonlinear smart base isolated building subject to near fault earthquakes
    Nagarajaiah, Satish
    Narasimhan, Sriram
    Johnson, Erik
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (05): : 653 - 656
  • [2] Cubic control for phase I smart base-isolated benchmark building with emphasis on nonstructural performance
    Xu, Xin
    Singh, Tarunraj
    Dargush, Gary F.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 758 - 774
  • [3] Semiactive control of a base isolated building using magnetorheological dampers
    Zapateiro, Mauricio
    Luo, Ningsu
    Karimi, Hamid Reza
    INTERNATIONAL JOURNAL OF MODELLING IDENTIFICATION AND CONTROL, 2009, 7 (01) : 41 - 48
  • [4] Smart base-isolated benchmark building part IV: Phase II sample controllers for nonlinear isolation systems
    Narasimhan, S.
    Nagarajaiah, S.
    Johnson, E. A.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (05): : 657 - 672
  • [5] Smart base-isolated benchmark building part IV: Phase II sample controllers for nonlinear isolation systems
    Department of Civil and Environmental Engineering, University of Waterloo, Waterloo, ON, Canada
    不详
    不详
    不详
    J. Struct. Control Health Monit., 5 (657-672):
  • [6] Robust active control of hysteretic base-isolated structures: Application to the benchmark smart base-isolated building
    Pozo, Francesc
    Montserrat, Pere Marc
    Rodellar, Jose
    Acho, Leonardo
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (05): : 720 - 736
  • [7] GA-fuzzy control of smart base isolated benchmark building using supervisory control technique
    Kim, Hyun-Su
    Roschke, Paul N.
    ADVANCES IN ENGINEERING SOFTWARE, 2007, 38 (07) : 453 - 465
  • [8] Structural control benchmark problem: Smart base isolated building subjected to near fault earthquakes
    Nagarajaiah, S
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 571 - 572
  • [9] Smart base-isolated benchmark building. Part II: phase I sample controllers for linear isolation systems
    Nagarajaiah, S.
    Narasimhan, S.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 589 - 604
  • [10] Seismic control of smart base isolated buildings with new semiactive variable damper
    Nagarajaiah, S.
    Narasimhan, S.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2007, 36 (06): : 729 - 749