Biopsy sampling of breast lesions: comparison of core needle- and vacuum-assisted breast biopsies

被引:28
作者
Lacambra, Maribel D. [1 ]
Lam, Christopher C. [1 ]
Mendoza, Paulo [1 ]
Chan, Siu Ki [2 ]
Yu, Alex M. [1 ]
Tsang, Julia Y. S. [1 ]
Tan, Puay Hoon [3 ]
Tse, Gary M. [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Anat & Cellular Pathol, Prince Wales Hosp, Shatin, Hong Kong, Peoples R China
[2] Kwong Wah Hosp, Dept Pathol, Hong Kong, Hong Kong, Peoples R China
[3] Singapore Gen Hosp, Dept Pathol, Singapore 0316, Singapore
关键词
Breast; Biopsy; Carcinoma; Calcification; CALCIFICATIONS; MICROCALCIFICATIONS; EXPERIENCE; ACCURACY; BENIGN;
D O I
10.1007/s10549-011-1639-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Needle biopsy is now the initial investigation of choice for the pre-operative diagnosis of breast lesions. This includes core needle biopsy (CNB) and vacuum-assisted biopsy (VAB) with or without radiologic assistance. The performance indices of both of these biopsy techniques were evaluated. In a large cohort of patients with breast lesions including 464 cases (285 CNB and 179 VAB), with confirmed outcomes, the diagnostic accuracy was compared using parameters including quantitation of the sampling based on the total number of cores taken, cores containing breast parenchyma, and cores with lesion; and non-epithelial changes including necrosis and calcification. CNB showed a 99% PPV, 94% NPV, 96% sensitivity, and 99% specificity, whereas VAB demonstrated a 100% PPV, 100% NPV, 100% sensitivity, and 100% specificity. The correct diagnosis in CNB was proportional to the number of cores extracted, whereas accuracy of VAB was independent of the total number of cores taken. There was a positive correlation between the presence of calcification and malignancy in CNB, but not detected under VAB. CNB and VAB were equally efficient in palpable lesions, in detecting necrosis, and calcification. Large calcification was found to be associated with malignancy in both CNB and VAB. In non-palpable lesions, VAB was more effective in the detection of calcification. The diagnostic accuracy of VAB appeared to be independent of number of cores sampled, whereas CNB required a minimum of 3-4 cores to achieve high diagnostic accuracy.
引用
收藏
页码:917 / 923
页数:7
相关论文
共 28 条
[21]   X-RAY CALCIFICATIONS AS THE ONLY BASIS FOR BREAST BIOPSY [J].
POWELL, RW ;
MCSWEENEY, MB ;
WILSON, CE .
ANNALS OF SURGERY, 1983, 197 (05) :555-559
[22]  
Rovera Francesca, 2008, Int J Surg, V6 Suppl 1, pS104, DOI 10.1016/j.ijsu.2008.12.009
[23]   Ultrasound-guided large-core needle biopsies of breast lesions: analysis of 962 cases to determine the number of samples for reliable tumour classification [J].
Sauer, G ;
Deissler, H ;
Strunz, K ;
Helms, G ;
Remmel, E ;
Koretz, K ;
Terinde, R ;
Kreienberg, R .
BRITISH JOURNAL OF CANCER, 2005, 92 (02) :231-235
[24]  
Su Kun-Lun, 2010, Zhonghua Zhong Liu Za Zhi, V32, P472
[25]   Stereotactic vacuum-assisted breast biopsy in 268 nonpalpable lesions [J].
Tonegutti M. ;
Girardi V. .
La radiologia medica, 2008, 113 (1) :65-75
[26]   Calcification in breast lesions: pathologists' perspective [J].
Tse, G. M. ;
Tan, P-H ;
Pang, A. L. M. ;
Tang, A. P. Y. ;
Cheung, H. S. .
JOURNAL OF CLINICAL PATHOLOGY, 2008, 61 (02) :145-151
[27]   Intermediate to highly suspicious calcification in breast lesions: a radio-pathologic correlation [J].
Tse, Gary M. ;
Tan, Puay-Hoon ;
Cheung, Humairah S. ;
Chu, Winnie C. W. ;
Lam, Wynnie W. M. .
BREAST CANCER RESEARCH AND TREATMENT, 2008, 110 (01) :1-7
[28]   Diagnosing breast lesions by fine needle aspiration cytology or core biopsy: which is better? [J].
Tse, Gary M. ;
Tan, Puay-Hoon .
BREAST CANCER RESEARCH AND TREATMENT, 2010, 123 (01) :1-8