On the performance enhancement of adaptive signal averaging: A means for improving the sensitivity and rate of data acquisition in magnetic resonance and other analytical measurements

被引:5
作者
Cochrane, C. J. [1 ]
机构
[1] Penn State Univ, Dept Engn Sci, University Pk, PA 16802 USA
关键词
TO-NOISE;
D O I
10.1063/1.4757869
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A few years back, our lab developed a signal averaging technique that greatly reduces the number of scans required to achieve a comparable signal-to-noise ratio to that of conventional signal averaging for continuous wave magnetic resonance measurements. We utilize an adaptive filter in a signal averaging scheme without any prior knowledge of the signal under observation. We termed this technique adaptive signal averaging (ASA). The technique was successful in reducing the noise variance by a factor of at least 10 in a single trace and is shown to converge in time by the same factor. ASA can also be useful in many other applications where signal averaging is utilized, such as medical imaging, electrocardiography, or electroencephalography. The purpose of this paper is to describe the advancements made to the technique, present a derivation of its performance enhancement, and illustrate the power of the technique through a set of simulations. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4757869]
引用
收藏
页数:8
相关论文
共 18 条
[1]   Adaptive template filtering for signal-to-noise ratio enhancement in magnetic resonance imaging [J].
Ahn, CB ;
Song, YC ;
Park, DJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (06) :549-556
[2]   Theory of time-domain measurement of spin-dependent recombination with pulsed electrically detected magnetic resonance [J].
Boehme, C ;
Lips, K .
PHYSICAL REVIEW B, 2003, 68 (24)
[3]   Note: Sensitivity enhancement in continuous-wave electron paramagnetic resonance: Adaptive signal averaging versus a moving average [J].
Brinton, Christopher G. ;
Hirsh, Donald J. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (02)
[4]   AVERAGE RESPONSE COMPUTER (ARC) - A DIGITAL DEVICE FOR COMPUTING AVERAGES AND AMPLITUDE AND TIME HISTOGRAMS OF ELECTROPHYSIOLOGICAL RESPONSES [J].
CLARK, WA ;
ZIEMAN, HE ;
MOLNAR, CE ;
GOLDSTEIN, MH ;
BROWN, RM ;
OBRIEN, DF .
IRE TRANSACTIONS ON BIOMEDICAL ELECTRONICS, 1961, BME8 (01) :46-&
[5]  
Cochrane C., 2010, ELECT PARAMAGNETIC R, V19, P10
[6]   Real time exponentially weighted recursive least squares adaptive signal averaging for enhancing the sensitivity of continuous wave magnetic resonance [J].
Cochrane, C. J. ;
Lenahan, P. M. .
JOURNAL OF MAGNETIC RESONANCE, 2008, 195 (01) :17-22
[7]   An adaptive filter for suppression of cardiac and respiratory noise in MRI time series data [J].
Deckers, Roel H. R. ;
van Gelderen, Peter ;
Ries, Mario ;
Barret, Olivier ;
Duyn, Jeff H. ;
Ikonomidou, Vasiliki N. ;
Fukunaga, Masaki ;
Glover, Gary H. ;
de Zwart, Jacco A. .
NEUROIMAGE, 2006, 33 (04) :1072-1081
[8]   A novel approach for the averaging of magnetocardiographically recorded heart beats [J].
DiPietroPaolo, D ;
Müller, HP ;
Erné, SN .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (10) :2415-2426
[9]  
Frances RJ, 2010, EXP CLIN CARDIOL, V15, pE61
[10]  
Gautam A., 2008, 3RD INTERNATIONAL CO, V1, P409