Review of 2 Decades of Aneurysm-Recurrence Literature, Part 1: Reducing Recurrence after Endovascular Coiling

被引:74
作者
Crobeddu, E. [2 ]
Lanzino, G. [1 ,2 ]
Kallmes, D. F. [1 ,2 ]
Cloft, H. J. [1 ,2 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Neurosurg, Rochester, MN 55905 USA
关键词
RUPTURED INTRACRANIAL ANEURYSMS; ANGIOGRAPHIC FOLLOW-UP; BARE PLATINUM COILS; CEREBRAL ANEURYSMS; PACKING DENSITY; FLOW-DIVERSION; ASSISTED COILING; DETACHABLE COILS; BRAIN ANEURYSMS; EMBOLIZATION;
D O I
10.3174/ajnr.A3032
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Angiographic recurrence following endovascular therapy is an indirect measure of the potential for hemorrhage. Because patients and physicians consider recurrence to be a suboptimal outcome with some chance of future hemorrhage, much effort has been expended to reduce the incidence of recurrence. The literature regarding aneurysm recurrence following endovascular therapy, spanning 2 decades, is extensive. We will review and summarize the effort to reduce recurrence following endovascular treatment of cerebral aneurysms.
引用
收藏
页码:266 / 270
页数:5
相关论文
共 61 条
[41]  
Pierot L, 2006, AM J NEURORADIOL, V27, P1693
[42]   Remodeling Technique for Endovascular Treatment of Ruptured Intracranial Aneurysms Had a Higher Rate of Adequate Postoperative Occlusion than Did Conventional Coil Embolization with Comparable Safety [J].
Pierot, Laurent ;
Cognard, Christophe ;
Anxionnat, Rene ;
Ricolfi, Frederic .
RADIOLOGY, 2011, 258 (02) :546-553
[43]   Intracranial aneurysms: Treatment with bare platinum coils - Aneurysm packing, complex coils, and angiographic recurrence [J].
Piotin, Michel ;
Spelle, Laurent ;
Mounayer, Charbel ;
Salles-Rezende, Marco T. ;
Giansante-Abud, Daniel ;
Vanzin-Santos, Ricardo ;
Moret, Jacques .
RADIOLOGY, 2007, 243 (02) :500-508
[44]   Stent-Assisted Coiling of Intracranial Aneurysms Clinical and Angiographic Results in 216 Consecutive Aneurysms [J].
Piotin, Michel ;
Blanc, Raphael ;
Spelle, Laurent ;
Mounayer, Charbel ;
Piantino, Rhelen ;
Schmidt, Paul J. ;
Moret, Jacques .
STROKE, 2010, 41 (01) :110-115
[45]   Sixteen-year single-surgeon experience with coil embolization for ruptured intracranial aneurysms: recurrence rates and incidence of late rebleeding Clinical article [J].
Plowman, R. Scooter ;
Clarke, Alison ;
Clarke, Mike ;
Byrne, James V. .
JOURNAL OF NEUROSURGERY, 2011, 114 (03) :863-874
[46]   Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils [J].
Raymond, J ;
Guilbert, F ;
Weill, A ;
Georganos, SA ;
Juravsky, L ;
Lambert, A ;
Lamoureux, J ;
Chagnon, M ;
Roy, D .
STROKE, 2003, 34 (06) :1398-1403
[47]   Follow-up of treated aneurysms: the challenge of recurrences and potential solutions [J].
Raymond, Jean ;
Guilbert, Francois ;
Weill, Alain ;
Roy, Daniel .
NEUROIMAGING CLINICS OF NORTH AMERICA, 2006, 16 (03) :513-+
[48]   Packing performance of helical guglielmi detachable coil (GDC) 18 in intracranial aneurysms: A comparison with helical GDC 10 coils and complex Trufill/Orbit coils [J].
Sluzewski, M. ;
van Rooij, W. J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (07) :1384-1387
[49]   Relation between aneurysm volume, packing, and compaction in 124 cerebral aneurysms treated with coils [J].
Sluzewski, M ;
van Rooij, WJ ;
Slob, MJ ;
Bescós, JO ;
Slump, CH ;
Wijnalda, D .
RADIOLOGY, 2004, 231 (03) :653-658
[50]   Treatment of Intracranial Aneurysms by Functional Reconstruction of the Parent Artery: The Budapest Experience with the Pipeline Embolization Device [J].
Szikora, I. ;
Berentei, Z. ;
Kulcsar, Z. ;
Marosfoi, M. ;
Vajda, Z. S. ;
Lee, W. ;
Berez, A. ;
Nelson, P. K. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (06) :1139-1147