Review of 2 Decades of Aneurysm-Recurrence Literature, Part 1: Reducing Recurrence after Endovascular Coiling

被引:74
作者
Crobeddu, E. [2 ]
Lanzino, G. [1 ,2 ]
Kallmes, D. F. [1 ,2 ]
Cloft, H. J. [1 ,2 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Neurosurg, Rochester, MN 55905 USA
关键词
RUPTURED INTRACRANIAL ANEURYSMS; ANGIOGRAPHIC FOLLOW-UP; BARE PLATINUM COILS; CEREBRAL ANEURYSMS; PACKING DENSITY; FLOW-DIVERSION; ASSISTED COILING; DETACHABLE COILS; BRAIN ANEURYSMS; EMBOLIZATION;
D O I
10.3174/ajnr.A3032
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Angiographic recurrence following endovascular therapy is an indirect measure of the potential for hemorrhage. Because patients and physicians consider recurrence to be a suboptimal outcome with some chance of future hemorrhage, much effort has been expended to reduce the incidence of recurrence. The literature regarding aneurysm recurrence following endovascular therapy, spanning 2 decades, is extensive. We will review and summarize the effort to reduce recurrence following endovascular treatment of cerebral aneurysms.
引用
收藏
页码:266 / 270
页数:5
相关论文
共 61 条
[21]   Clinical and angiographic results of endosaccular coiling treatment of giant and very large intracranial aneurysms: A 7-year, single-center experience [J].
Gruber, A ;
Killer, M ;
Bavinzski, G ;
Richling, B .
NEUROSURGERY, 1999, 45 (04) :793-803
[22]   Chronic shunt-dependent hydrocephalus after early surgical and early endovascular treatment of ruptured intracranial aneurysms [J].
Gruber, A ;
Reinprecht, A ;
Bavinzski, G ;
Czech, T ;
Richling, B .
NEUROSURGERY, 1999, 44 (03) :503-509
[23]   Influence of Coil Geometry on Intra-Aneurysmal Packing Density: Evaluation of a New Primary Wind Technology [J].
Grunwald, Iris Quasar ;
Molyneux, Andrew ;
Kuehn, Anna Luisa ;
Watson, Dave ;
Byrne, James V. .
VASCULAR AND ENDOVASCULAR SURGERY, 2010, 44 (04) :289-293
[24]   ENDOVASCULAR TREATMENT OF POSTERIOR CIRCULATION ANEURYSMS BY ELECTROTHROMBOSIS USING ELECTRICALLY DETACHABLE COILS [J].
GUGLIELMI, G ;
VINUELA, F ;
DUCKWILER, G ;
DION, J ;
LYLYK, P ;
BERENSTEIN, A ;
STROTHER, C ;
GRAVES, V ;
HALBACH, V ;
NICHOLS, D ;
HOPKINS, N ;
FERGUSON, R ;
SEPETKA, I .
JOURNAL OF NEUROSURGERY, 1992, 77 (04) :515-524
[25]   The adverse effects of flow-diverter stent-like devices on the flow pattern of saccular intracranial aneurysm models: computational fluid dynamics study [J].
Hassan, Tamer ;
Ahmed, Yasser Mohamed ;
Hassan, Amr Ali .
ACTA NEUROCHIRURGICA, 2011, 153 (08) :1633-1640
[26]   Angiographic and clinical results in 316 coil-treated basilar artery bifurcation aneurysms [J].
Henkes, H ;
Fischer, S ;
Mariushi, W ;
Weber, W ;
Liebig, T ;
Miloslavski, E ;
Brew, S ;
Kühne, D .
JOURNAL OF NEUROSURGERY, 2005, 103 (06) :990-999
[27]  
Hope JKA, 1999, AM J NEURORADIOL, V20, P391
[28]   Comparison of 2-Year Angiographic Outcomes of Stent- and Nonstent-Assisted Coil Embolization in Unruptured Aneurysms with an Unfavorable Configuration for Coiling [J].
Hwang, G. ;
Park, H. ;
Bang, J. S. ;
Jin, S. -C. ;
Kim, B. C. ;
Oh, C. W. ;
Kang, H. S. ;
Han, M. H. ;
Kwon, O. -K. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (09) :1707-1710
[29]  
JOHNSTON SC, 2011, P SOC NEUR SURG 8 AN
[30]   Endovascular occlusion of intracranial aneurysms with Guglielmi detachable coils: Correlation between coil packing density and coil compaction [J].
Kawanabe, Y ;
Sadato, A ;
Taki, W ;
Hashimoto, N .
ACTA NEUROCHIRURGICA, 2001, 143 (05) :451-455