Review of 2 Decades of Aneurysm-Recurrence Literature, Part 1: Reducing Recurrence after Endovascular Coiling

被引:72
作者
Crobeddu, E. [2 ]
Lanzino, G. [1 ,2 ]
Kallmes, D. F. [1 ,2 ]
Cloft, H. J. [1 ,2 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Neurosurg, Rochester, MN 55905 USA
关键词
RUPTURED INTRACRANIAL ANEURYSMS; ANGIOGRAPHIC FOLLOW-UP; BARE PLATINUM COILS; CEREBRAL ANEURYSMS; PACKING DENSITY; FLOW-DIVERSION; ASSISTED COILING; DETACHABLE COILS; BRAIN ANEURYSMS; EMBOLIZATION;
D O I
10.3174/ajnr.A3032
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Angiographic recurrence following endovascular therapy is an indirect measure of the potential for hemorrhage. Because patients and physicians consider recurrence to be a suboptimal outcome with some chance of future hemorrhage, much effort has been expended to reduce the incidence of recurrence. The literature regarding aneurysm recurrence following endovascular therapy, spanning 2 decades, is extensive. We will review and summarize the effort to reduce recurrence following endovascular treatment of cerebral aneurysms.
引用
收藏
页码:266 / 270
页数:5
相关论文
共 61 条
  • [21] Clinical and angiographic results of endosaccular coiling treatment of giant and very large intracranial aneurysms: A 7-year, single-center experience
    Gruber, A
    Killer, M
    Bavinzski, G
    Richling, B
    [J]. NEUROSURGERY, 1999, 45 (04) : 793 - 803
  • [22] Chronic shunt-dependent hydrocephalus after early surgical and early endovascular treatment of ruptured intracranial aneurysms
    Gruber, A
    Reinprecht, A
    Bavinzski, G
    Czech, T
    Richling, B
    [J]. NEUROSURGERY, 1999, 44 (03) : 503 - 509
  • [23] Influence of Coil Geometry on Intra-Aneurysmal Packing Density: Evaluation of a New Primary Wind Technology
    Grunwald, Iris Quasar
    Molyneux, Andrew
    Kuehn, Anna Luisa
    Watson, Dave
    Byrne, James V.
    [J]. VASCULAR AND ENDOVASCULAR SURGERY, 2010, 44 (04) : 289 - 293
  • [24] ENDOVASCULAR TREATMENT OF POSTERIOR CIRCULATION ANEURYSMS BY ELECTROTHROMBOSIS USING ELECTRICALLY DETACHABLE COILS
    GUGLIELMI, G
    VINUELA, F
    DUCKWILER, G
    DION, J
    LYLYK, P
    BERENSTEIN, A
    STROTHER, C
    GRAVES, V
    HALBACH, V
    NICHOLS, D
    HOPKINS, N
    FERGUSON, R
    SEPETKA, I
    [J]. JOURNAL OF NEUROSURGERY, 1992, 77 (04) : 515 - 524
  • [25] The adverse effects of flow-diverter stent-like devices on the flow pattern of saccular intracranial aneurysm models: computational fluid dynamics study
    Hassan, Tamer
    Ahmed, Yasser Mohamed
    Hassan, Amr Ali
    [J]. ACTA NEUROCHIRURGICA, 2011, 153 (08) : 1633 - 1640
  • [26] Angiographic and clinical results in 316 coil-treated basilar artery bifurcation aneurysms
    Henkes, H
    Fischer, S
    Mariushi, W
    Weber, W
    Liebig, T
    Miloslavski, E
    Brew, S
    Kühne, D
    [J]. JOURNAL OF NEUROSURGERY, 2005, 103 (06) : 990 - 999
  • [27] Hope JKA, 1999, AM J NEURORADIOL, V20, P391
  • [28] Comparison of 2-Year Angiographic Outcomes of Stent- and Nonstent-Assisted Coil Embolization in Unruptured Aneurysms with an Unfavorable Configuration for Coiling
    Hwang, G.
    Park, H.
    Bang, J. S.
    Jin, S. -C.
    Kim, B. C.
    Oh, C. W.
    Kang, H. S.
    Han, M. H.
    Kwon, O. -K.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (09) : 1707 - 1710
  • [29] JOHNSTON SC, 2011, P SOC NEUR SURG 8 AN
  • [30] Endovascular occlusion of intracranial aneurysms with Guglielmi detachable coils: Correlation between coil packing density and coil compaction
    Kawanabe, Y
    Sadato, A
    Taki, W
    Hashimoto, N