Flow injection determination of peroxide value in edible oils using triiodide detector

被引:32
作者
Saad, B [1 ]
Wai, WT [1 ]
Lim, BP [1 ]
Saleh, MI [1 ]
机构
[1] Univ Sains Malaysia, Sch Chem Sci, George Town 11800, Malaysia
关键词
peroxide value; edible oil; flow injection analysis; triiodide electrode;
D O I
10.1016/j.aca.2006.02.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection analysis (FIA) method for the determination of peroxide value (PV) in edible oils is described. Oil sample (undiluted) and KI reagent were aspirated into a homemade reaction chamber where the redox reaction between iodide in the aqueous phase and hydroperoxides in the oil was effected by applying a short (typically 30 s) vortex action. After allowing for the emulsified oil phase to be separated from the aqueous phase (bottom layer), an aliquot of the aqueous phase containing triiodide was next aspirated to the surface of a triiodide-selective membrane for detection. The optimized FIA procedure is linear over 0.35-28.0 PV (mequiv. O-2/kg) with a detection limit of 0.32 PV. Exhibiting good reproducibility (R.S.D. of 2.7% (n = 8) for the determination of 1.1 PV) and sampling rate of 80 samples h(-1), the proposed method, unlike previous FIA procedures, completely eliminated the use of organic solvents (except the use of 2-propanol for cleaning of reaction chamber). Excellent correlation (R-2 = 0.9949) between the proposed method and the manual official AOCS method was found when applied to the determination of PV in diverse type of edible oils (n = 20). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:261 / 270
页数:10
相关论文
共 56 条
[1]   AUTOMATIC-DETERMINATION OF HYDROPEROXIDES OF PHOSPHATIDYLCHOLINE AND PHOSPHATIDYLETHANOLAMINE IN HUMAN PLASMA [J].
AKASAKA, K ;
OHATA, A ;
OHRUI, H ;
MEGURO, H .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 665 (01) :37-43
[2]   SIMULTANEOUS DETERMINATION OF HYDROPEROXIDES OF PHOSPHATIDYLCHOLINE, CHOLESTEROL ESTERS AND TRIACYLGLYCEROLS BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH A POSTCOLUMN DETECTION SYSTEM [J].
AKASAKA, K ;
OHRUI, H ;
MEGURO, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 622 (02) :153-159
[3]   Development of phosphine reagents for the high-performance liquid chromatographic-fluorometric determination of lipid hydroperoxides [J].
Akasaka, K ;
Ohrui, H .
JOURNAL OF CHROMATOGRAPHY A, 2000, 881 (1-2) :159-170
[4]  
AKASAKA K, 1998, J JPN OIL CHEM SOC, V47, P135
[5]   COLORIMETRIC DETERMINATION OF LIPID HYDROPEROXIDES IN OILS AND FATS WITH MICROPEROXIDASE [J].
AKAZA, I ;
AOTA, N .
TALANTA, 1990, 37 (09) :925-929
[6]  
*AM OIL CHEM SOC, 1996, OFF METH REC PRACT A
[7]   Enzymic determination of peroxides in non-aqueous media [J].
Avila, GP ;
Salvador, A ;
de la Guardia, M .
ANALYST, 1997, 122 (12) :1543-1547
[8]   Development of a flow injection chemiluminescent assay for the quantification of lipid hydroperoxides [J].
Bunting, JP ;
Gray, DA .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 2003, 80 (10) :951-955
[9]   Determination of hydroperoxides in nonaqueous solvents or mixed solvents, using a biosensor with two antagonist enzymes operating in parallel [J].
Campanella, L ;
Giancola, D ;
Gregori, E ;
Tomassetti, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 95 (1-3) :321-327
[10]   A CRITICAL COMPARISON OF METHODS FOR HYDROPEROXIDE MEASUREMENT IN OXIDIZED POLYOLEFINS [J].
CARLSSON, DJ ;
LACOSTE, J .
POLYMER DEGRADATION AND STABILITY, 1991, 32 (03) :377-386