Wrist ROM measurements using smartphone photography: Reliability and validity

被引:10
作者
Ge, M. [1 ]
Chen, J. [1 ]
Zhu, Z. J. [2 ]
Shi, P. [1 ]
Yin, L. R. [3 ]
Xia, L. [4 ]
机构
[1] Nantong Univ, Dept Hand Surg, Affiliated Hosp, 20 West Temple Rd, Nantong 226001, Jiangsu, Peoples R China
[2] Nantong Univ, Dept Rehabil, Affiliated Hosp, 20 West Temple Rd, Nantong 226001, Jiangsu, Peoples R China
[3] Nantong Univ, Dept Nursing Training Ctr, Affiliated Hosp, 20 West Temple Rd, Nantong 226001, Jiangsu, Peoples R China
[4] Nantong Univ, Nursing Training Ctr, Affiliated Hosp, 20 West Temple Rd, Nantong 226001, Jiangsu, Peoples R China
关键词
Smartphone; Wrist; Motion; Measurement; DIGITAL PHOTOGRAPHY; RANGE; MOTION; GONIOMETRY; ASSOCIATION; ELBOW;
D O I
10.1016/j.hansur.2020.02.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
No one has validated measuring the wrist's active range of motion (ROM) using smartphone images in patients. It is not known whether pathological factors affect the accuracy of this measurement technique. The purpose of this study was to assess if smartphone photography is as reliable and valid as manual goniometry for measuring wrist joint ROM. We reviewed 38 wrists in 38 patients (21 women and 17 men) with a mean age of 45 years (range, 26-60). Smartphones were used to take digital photos of injured wrists at extremes of wrist motion, including flexion, extension, radial and ulnar deviation. The mean difference in measured ROM between the two measurement methods (digital photos and handheld goniometer) was compared using Student's t test and the relationship determined using Pearson correlation coefficients. Bland-Altman analysis was used to define the limits of agreement (LOA). No significant difference was found when comparing the wrist ROM in the four positions using manual goniometry and digital measurements from photos taken by a surgeon. Between the goniometer measurements and digital photos taken by a surgeon, the Pearson coefficients were high, with most being above 0.8 for the four positions. The Pearson coefficients also show the smartphone measurements were highly precise. There was high reliability between the photographs taken by surgeons and by patients, as well as high interobserver reliability. Smartphone photography is a reliable and valid method to measure wrist joint ROM in patients. This measurement method can be used to measure outcomes. (C) 2020 SFCM. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:261 / 264
页数:4
相关论文
共 19 条
[1]   Reliability of range-of-motion measurement in the elbow and forearm [J].
Armstrong, AD ;
MacDermid, JC ;
Chinchalkar, S ;
Stevens, RS ;
King, GJW .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 1998, 7 (06) :573-580
[2]   Measurement of knee joint motion using digital imaging [J].
Bennett, Damien ;
Hanratty, Brian ;
Thompson, Neville ;
Beverland, David .
INTERNATIONAL ORTHOPAEDICS, 2009, 33 (06) :1627-1631
[3]   Validation of a photography-based goniometry method for measuring joint range of motion [J].
Blonna, Davide ;
Zarkadas, Peter C. ;
Fitzsimmons, James S. ;
O'Driscoll, Shawn W. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (01) :29-35
[4]   Accuracy and Reliability of Three Different Techniques for Manual Goniometry for Wrist Motion: A Cadaveric Study [J].
Carter, Timothy I. ;
Pansy, Brian ;
Wolff, Aviva L. ;
Hillstrom, Howard J. ;
Backus, Sherry I. ;
Lenhoff, Mark ;
Wolfe, Scott W. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (08) :1422-1428
[5]   Validity of Goniometric Elbow Measurements: Comparative Study with a Radiographic Method [J].
Chapleau, Julien ;
Canet, Fanny ;
Petit, Yvan ;
Laflamme, G-Yves ;
Rouleau, Dominique M. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (11) :3134-3140
[6]   Reliability of a smartphone-based goniometer for knee joint goniometry [J].
Ferriero, Giorgio ;
Vercelli, Stefano ;
Sartorio, Francesco ;
Munoz Lasa, Susana ;
Ilieva, Elena ;
Brigatti, Elisa ;
Ruella, Carolina ;
Foti, Calogero .
INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2013, 36 (02) :146-151
[7]   CLINICAL MEASUREMENT OF RANGE OF MOTION - REVIEW OF GONIOMETRY EMPHASIZING RELIABILITY AND VALIDITY [J].
GAJDOSIK, RL ;
BOHANNON, RW .
PHYSICAL THERAPY, 1987, 67 (12) :1867-1872
[8]   Lateral digital photography with computer-aided goniometry versus standard goniometry for recording finger joint angles [J].
Georgeu, GA ;
Mayfield, S ;
Logan, AM .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2002, 27B (02) :184-186
[9]   Association between objective clinical variables and patient-rated disability of the wrist [J].
Karnezis, IA ;
Fragkiadakis, EG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (07) :967-970
[10]   A Comparison of Elbow Range of Motion Measurements: Smartphone-Based Digital Photography Versus Goniometric Measurements [J].
Meislin, Megan A. ;
Wagner, Eric R. ;
Shin, Alexander Y. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2016, 41 (04) :510-515