Studies of compressor pressure ratio effect on GAXAC (generator-absorber-exchange absorption compression) cooler

被引:43
作者
Kumar, A. Ramesh [1 ]
Udayakumar, M. [2 ]
机构
[1] Thiagarajar Coll Engn, Dept Mech Engn, Madurai 625015, Tamil Nadu, India
[2] Natl Inst Technol, Dept Mech Engn, Tiruchirappalli 620015, Tamil Nadu, India
关键词
GAX; ammonia-water; pressure ratio; absorption-compression; simulation;
D O I
10.1016/j.apenergy.2008.03.002
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents simulation studies conducted on a GAXAC cycle of capacity 3.514 kW using ammonia-water as working fluid for cooling applications. The low side pressure ratio of (compressor pressure ratio) of the cycle has been optimized for optimum COP. The effects of temperatures of the generator, condenser, absorber and evaporator on the COP of the cycle as a function of low side pressure ratio have been studied. The effect of the low side pressure ratio on the heat duties (kW) of the cycle has also been studied. It is found that for a given value of desorber and approach temperatures, the optimum COP corresponding to the optimum pressure ratio is independent of the temperatures of condenser, absorber and evaporator. The optimum COP for the desorber temperatures 110 degrees C, 130 degrees C, 150 degrees C and approach temperature 14 degrees C at all optimum pressure ratios are found to be 1.00, 0.97 and 0.94, respectively. Comparison of GAXAC and standard GAX cycle was carried out and found that GAXAC cycle has 26% higher value of COP than the standard GAX cycle. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1163 / 1172
页数:10
相关论文
共 10 条
[1]  
Grossman G, 1995, ASHRAE TRAN, V101, P1313
[2]  
HEROLD KE, 1991, P ABS HEAT PUMP C TO, P127
[3]   Performance analysis of advanced hybrid GAX cycles: HGAX [J].
Kang, YT ;
Hong, H ;
Park, KS .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (04) :442-448
[4]   Simulation studies on GAX absorption compression cooler [J].
Kumar, A. Ramesh ;
Udayakumar, M. .
ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (09) :2604-2610
[5]   SIMPLE FUNCTIONS FOR FAST CALCULATIONS OF SELECTED THERMODYNAMIC PROPERTIES OF THE AMMONIA-WATER SYSTEM [J].
PATEK, J ;
KLOMFAR, J .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (04) :228-234
[6]  
PRIEDEMAN DK, 1999, ASHRAE T, P769
[7]  
Sharfe J., 1986, INT J REFRIG, V9, P326
[8]   POLYBRANCHED REGENERATIVE GAX COOLING CYCLES [J].
STAICOVICI, MD .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (05) :318-329
[9]   Comparison of the performances of NH3-H2O, NH3-LiNO3 and NH3-NaSCN absorption refrigeration systems [J].
Sun, DW .
ENERGY CONVERSION AND MANAGEMENT, 1998, 39 (5-6) :357-368
[10]   Methodology for the energy analysis of an air cooled GAX absorption heat pump operated by natural gas and solar energy [J].
Velázquez, N ;
Best, R .
APPLIED THERMAL ENGINEERING, 2002, 22 (10) :1089-1103