Ultrasensitive electrochemical sensor for simultaneous determination of cadmium and lead ions based on one-step co-electropolymerization strategy

被引:41
作者
Fang, Yishan [1 ,2 ]
Cui, Bo [1 ,2 ]
Huang, Jianzhi [3 ]
Wang, Lishi [3 ]
机构
[1] Qilu Univ Technol, State Key Lab Biobased Mat & Green Papermaking, Shandong Acad Sci, Jinan 250353, Shandong, Peoples R China
[2] Qilu Univ Technol Technol, Sch Food Sci & Engn, Shandong Acad Sci, Jinan 250353, Shandong, Peoples R China
[3] South China Univ Technol, Sch Chem & Chem Engn, Guangzhou 510641, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemical sensor; Polyfurfural; Nanoporous silica; Ultrasensitive; Cadmium; Lead ions; HEAVY-METAL IONS; SIMULTANEOUS STRIPPING DETERMINATION; GLASSY-CARBON ELECTRODE; GRAPHENE OXIDE; FILM ELECTRODE; BLOOD LEAD; NANOPARTICLES; MERCURY; DEVICE; RAMAN;
D O I
10.1016/j.snb.2018.12.148
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A convenient and novel electrochemical strategy for simultaneous detection of cadmium ion (Cd2+) and lead ion (Pb2+) was established in this work. Well identifiable stripping peaks for Cd2+ and Pb2+ were achieved based on a three-dimensional nanoporous silica incorporated with polyfurfural modified glassy carbon electrode (GCE) by one-step co-electropolymerization. The polyfurfural was merged into nanoporous silica in order to enhance the sensor performance through improving the electrode surface area, supplying more binding sites for coordinating with metal ions. The prepared sensor exhibits more excellent electroactive surface area and excellent analytical properties than those just polyfurfural film modified GCE or just nanoporous silica on GCE. Comparing the traditional method, the proposed strategy displays high stability, reliability, favorable sensitivity, and outstanding selectivity for the simultaneous detecting Cd2+ and Pb2+. Impressively, this proposed strategy possessed a wide linear range of 1.5 ng/L to 6200 mu g/L and a low limit of detection (LOD) of 0.9 ng/L (S/N = 3) for Cd2+, while linear response range with 0.05 ng/L to 5200 mu g/L and LOD of 0.02 ng/L (S/N = 3) for Pb2+. In particular, the fabricated sensor had splendid analytical performance for detection of target ions in potable water, and satisfactory results have been obtained in practice.
引用
收藏
页码:414 / 420
页数:7
相关论文
共 75 条
[1]   Raman and IR investigation of silica nanoparticles structure [J].
Alessi, A. ;
Agnello, S. ;
Buscarino, G. ;
Gelardi, F. M. .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 2013, 362 :20-24
[2]   Preparation and characterization of magnetic nanocomposite of Schiff base/silica/magnetite as a preconcentration phase for the trace determination of heavy metal ions in water, food and biological samples using atomic absorption spectrometry [J].
Bagheri, Hasan ;
Afkhami, Abbas ;
Saber-Tehrani, Mohammad ;
Khoshsafar, Hosein .
TALANTA, 2012, 97 :87-95
[3]   A review on various electrochemical techniques for heavy metal ions detection with different sensing platforms [J].
Bansod, BabanKumar ;
Kumar, Tejinder ;
Thakur, Ritula ;
Rana, Shakshi ;
Singh, Inderbir .
BIOSENSORS & BIOELECTRONICS, 2017, 94 :443-455
[4]  
Bard A.J., 2001, ELECROCHEMICAL METHO, V2nd
[5]   Spherical nanoparticles of europium-doped silica-calcia glass and glass-ceramic: Spectroscopic characterization [J].
Borak, Beata ;
Krzak, Justyna ;
Ptak, Maciej ;
Strek, Wieslaw ;
Lukowiak, Anna .
JOURNAL OF MOLECULAR STRUCTURE, 2018, 1166 :48-53
[6]   Simultaneous detection of ultratrace lead and copper with gold nanoparticles patterned on carbon nanotube thin film [J].
Bui, Minh-Phuong Ngoc ;
Li, Cheng Ai ;
Han, Kwi Nam ;
Pham, Xuan-Hung ;
Seong, Gi Hun .
ANALYST, 2012, 137 (08) :1888-1894
[7]   Bismuth nanoparticles integration into heavy metal electrochemical stripping sensor [J].
Cadevall, Miquel ;
Ros, Josep ;
Merkoci, Arben .
ELECTROPHORESIS, 2015, 36 (16) :1872-1879
[8]   Electrochemical aptasensor for mucin 1 based on dual signal amplification of poly(o-phenylenediamine) carrier and functionalized carbon nanotubes tracing tag [J].
Chen, Xiaojun ;
Zhang, Qi ;
Qian, Chunhua ;
Hao, Ning ;
Xu, Lin ;
Yao, Cheng .
BIOSENSORS & BIOELECTRONICS, 2015, 64 :485-492
[9]   Electrochemical behavior of poly (naphthol green B)-film modified carbon paste electrode and its application for the determination of dopamine and uric acid [J].
Chitravathi, S. ;
Swamy, B. E. Kumara ;
Mamatha, G. P. ;
Sherigara, B. S. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 667 :66-75
[10]   Porous silica supports for micro-Raman spectroscopic studies of individual living cells [J].
Cristini-Robbe, O. ;
Raulin, K. ;
Dubart, F. ;
Bernard, R. ;
Kinowski, C. ;
Damene, N. ;
El Yazidi, I. ;
Boed, A. ;
Turrell, S. .
JOURNAL OF MOLECULAR STRUCTURE, 2013, 1050 :232-237