Left ventricular ejection fraction: Comparison of results from planar and SPECT gated blood-pool studies

被引:0
作者
Bartlett, ML [1 ]
Srinivasan, G [1 ]
Barker, WC [1 ]
Kitsiou, AN [1 ]
Dilsizian, V [1 ]
Bacharach, SL [1 ]
机构
[1] NIH,DEPT NUCL MED,BETHESDA,MD 20892
关键词
ejection fraction; SPECT gated blood-pool imaging; left ventricular function;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Global ejection fraction (EF) from planar gated blood-pool (GBP) imaging is a widely accepted measure of cardiac function. It has been suggested that planar GBP could be replaced by SPECT. In this article, we compare counts-based global EF measured from SPECT and planar images and investigate reasons for discrepancies between the two. Methods: Twenty-three subjects were imaged with both planar and SPECT GBP. SPECT short-axis slices were projected to create reprojected images. Reprojected SPECT (rSPECT) images were created in both the true long-axis view and also in a view typical of planar studies (found to be 60 degrees from the true long-axis). Thus, angle of view effects on global EF could be investigated. In addition, we studied the effects of background and attenuation. Results: Long-axis rSPECT EF correlated well with planar EF (r = 0.89) but EF values were significantly higher for rSPECT than for planar (slope = 1.4, intercept = -8 EF units; p < 0.001). We found that background correction may not be necessary with rSPECT, but neither background nor attenuation explained the observed discrepancy between rSPECT and planar EFs. This discrepancy was found to be caused by atrial overlap in the planar image and disappeared when the SPECT slices were reprojected at the same angle of view as the planar images. Conclusion: Global EF can be easily measured from rSPECT GBP images. Long-axis rSPECT EFs are, however, greater than planar EFs by a factor of 1.4 because atrial overlap causes a significant drop in planar EF in planar images. These results suggest that (long-axis) rSPECT EFs may be more accurate than planar EFs.
引用
收藏
页码:1795 / 1799
页数:5
相关论文
共 14 条
[1]   REAL-TIME RADIONUCLIDE CINEANGIOGRAPHY IN NONINVASIVE EVALUATION OF GLOBAL AND REGIONAL LEFT-VENTRICULAR FUNCTION AT REST AND DURING EXERCISE IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
BORER, JS ;
BACHARACH, SL ;
GREEN, MV ;
KENT, KM ;
EPSTEIN, SE ;
JOHNSTON, GS .
NEW ENGLAND JOURNAL OF MEDICINE, 1977, 296 (15) :839-844
[2]   QUANTITATIVE GATED BLOOD POOL TOMOGRAPHIC ASSESSMENT OF REGIONAL EJECTION FRACTION - DEFINITION OF NORMAL LIMITS [J].
CERQUEIRA, MD ;
HARP, GD ;
RITCHIE, JL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (04) :934-941
[3]   TOMOGRAPHIC GATED BLOOD POOL RADIONUCLIDE VENTRICULOGRAPHY - ANALYSIS OF WALL MOTION AND LEFT-VENTRICULAR VOLUMES IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
CORBETT, JR ;
JANSEN, DE ;
LEWIS, SE ;
GABLIANI, GI ;
NICOD, P ;
FILIPCHUK, NG ;
REDISH, GA ;
AKERS, MS ;
WOLFE, CL ;
RELLAS, JS ;
PARKEY, RW ;
WILLERSON, JT .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (02) :349-358
[4]   ASSESSMENT OF LEFT-VENTRICULAR REGIONAL WALL-MOTION WITH BLOOD-POOL TOMOGRAPHY - COMPARISON OF 11CO PET WITH TC-99M SPECT [J].
CROSS, SJ ;
LEE, HS ;
METCALFE, MJ ;
NORTON, MY ;
EVANS, NTS ;
WALTON, S .
NUCLEAR MEDICINE COMMUNICATIONS, 1994, 15 (04) :283-288
[5]  
DILSIZIAN V, 1990, J NUCL MED, V31, P10
[6]  
Gibbons R J, 1990, Curr Probl Cardiol, V15, P301
[7]  
GILL JB, 1986, J NUCL MED, V27, P1916
[8]   COMPARISON OF TOMOGRAPHIC AND PLANAR RADIONUCLIDE VENTRICULOGRAPHY IN THE ASSESSMENT OF REGIONAL LEFT-VENTRICULAR FUNCTION IN PATIENTS WITH LEFT-VENTRICULAR ANEURYSM BEFORE AND AFTER SURGERY [J].
LU, P ;
LIU, XJ ;
SHI, RF ;
MO, LJ ;
BORER, JS .
JOURNAL OF NUCLEAR CARDIOLOGY, 1994, 1 (06) :537-545
[9]  
MILLER TR, 1994, J NUCL MED, V35, P999
[10]   ECG-GATED EMISSION COMPUTED-TOMOGRAPHY OF THE CARDIAC BLOOD POOL [J].
MOORE, ML ;
MURPHY, PH ;
BURDINE, JA .
RADIOLOGY, 1980, 134 (01) :233-235