MRI-guided percutaneous coaxial cutting needle biopsy of small pulmonary nodules: feasibility

被引:9
作者
Liu, Ming [1 ]
Lv, Yubo [1 ]
Wu, Lebin [1 ]
Song, Jiqing [2 ]
Sequeiros, Roberto Blanco [3 ]
Li, Chengli [1 ]
机构
[1] Shandong Univ, Shandong Med Imaging Res Inst, Dept Intervent MRI, Jinan 250100, Shandong, Peoples R China
[2] Shandong Univ, Shandong Prov Hosp, Dept Radiol, Jinan 250100, Shandong, Peoples R China
[3] Oulu Univ Hosp, Dept Radiol, Oulu, Finland
关键词
Magnetic resonance; Interventional radiology; Lung biopsy; Technology; Guidance; ASPIRATION BIOPSY; DIAGNOSTIC-ACCURACY; LUNG-BIOPSY; PATIENT; GUIDANCE; CANCER;
D O I
10.1007/s00330-013-2871-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To prospectively evaluate the feasibility, safety and accuracy of magnetic resonance imaging (MRI)-guided percutaneous coaxial cutting needle biopsy of small (a parts per thousand currency sign2.0 cm in diameter) pulmonary nodules. Ninety-six patients (56 men and 40 women) with 96 small lung nodules underwent MRI-guided percutaneous coaxial cutting needle biopsy. These lesions were divided into two groups according to maximum nodule diameters: 0.5-1.0 cm (n = 25) and 1.1-2.0 cm (n = 71). The diagnostic accuracy, sensitivity and specificity were calculated, and comparison of the two groups was performed using Fisher's exact test. All specimens obtained were sufficient for diagnosis. Histological examination of needle biopsy revealed 64 malignant, 30 benign and 2 indeterminate nodules. The final diagnoses from surgery or clinical follow-up were 67 malignant nodules and 29 benign nodules. The diagnostic performance of MRI-guided percutaneous coaxial cutting needle biopsy in diagnosing malignant tumours was as follows: accuracy, 97 %; sensitivity, 96 %; specificity, 100 %; positive predictive value, 100 %; and negative predictive value, 91 %. There was no significant difference between the two groups (P > 0.05, Fisher's exact test). No serious complications occurred. MRI-guided percutaneous coaxial cutting needle biopsy is a safe and accurate diagnostic technique in the evaluation of small lung nodules. aEuro cent MRI-guided biopsy helps clinicians to assess patients with small lung nodules. aEuro cent Differentiation of malignant and benign nodules is possible with 97 % accuracy. aEuro cent MRI guidance enables accurate lung biopsy without ionising radiation. aEuro cent No serious complications occurred in MRI-guided lung biopsy.
引用
收藏
页码:2730 / 2738
页数:9
相关论文
共 34 条
[1]   Transthoracic needle biopsy of lung masses: a survey of techniques [J].
Aviram, G ;
Schwartz, DS ;
Meirsdorf, S ;
Rosen, G ;
Greif, J ;
Graif, M .
CLINICAL RADIOLOGY, 2005, 60 (03) :370-374
[2]   Evaluation of patient and staff doses during various CT fluoroscopy guided interventions [J].
Buls, N ;
Pagés, J ;
de Mey, J ;
Osteaux, M .
HEALTH PHYSICS, 2003, 85 (02) :165-173
[3]   The New Lung Cancer Staging System [J].
Detterbeck, Frank C. ;
Boffa, Daniel J. ;
Tanoue, Lynn T. .
CHEST, 2009, 136 (01) :260-271
[4]   Magnetic Resonance Imaging-Guided Osseous Biopsy in Children With Chronic Recurrent Multifocal Osteomyelitis [J].
Fritz, Jan ;
Tzaribachev, Nikolay ;
Thomas, Christoph ;
Wehrmann, Manfred ;
Horger, Marius S. ;
Carrino, John A. ;
Koenig, Claudius W. ;
Pereira, Philippe L. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 35 (01) :146-153
[5]   CT-GUIDED FINE-NEEDLE ASPIRATIONS FOR DIAGNOSIS OF BENIGN AND MALIGNANT DISEASE [J].
HARTER, LP ;
MOSS, AA ;
GOLDBERG, HI ;
GROSS, BH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 140 (02) :363-367
[6]   Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses [J].
Heck, SL ;
Blom, P ;
Berstad, A .
EUROPEAN RADIOLOGY, 2006, 16 (06) :1387-1392
[7]   C-Arm Cone-Beam CT-Guided Percutaneous Transthoracic Lung Biopsy: Usefulness in Evaluation of Small Pulmonary Nodules [J].
Hwang, Hye Sun ;
Chung, Myung Jin ;
Lee, Ju Won ;
Shin, Sung Wook ;
Lee, Kyung Soo .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) :W400-W407
[8]   MRI-guided abdominal biopsy in a 0.23-T open-configuration MRI system [J].
Kariniemi, J ;
Sequeiros, RB ;
Ojala, R ;
Tervonen, O .
EUROPEAN RADIOLOGY, 2005, 15 (06) :1256-1262
[9]   Transthoracic needle aspiration in patients with severe emphysema - A study of lung transplant candidates [J].
Kazerooni, EA ;
Hartker, FW ;
Whyte, RI ;
Martinez, FJ ;
Lynch, JP .
CHEST, 1996, 109 (03) :616-619
[10]   Magnetic resonance-guided upper abdominal biopsies in a high-field wide-bore 3-T MRI system: feasibility, handling, and needle artefacts [J].
Kuehn, Jens-Peter ;
Langner, Soenke ;
Hegenscheid, Katrin ;
Evert, Matthias ;
Kickhefel, Antje ;
Hosten, Norbert ;
Puls, Ralf .
EUROPEAN RADIOLOGY, 2010, 20 (10) :2414-2421