Quantitative comparison of technetium-99m tetrofosmin and thallium-201 images of the thyroid and abnormal parathyroid glands

被引:10
作者
Giordano, A
Marozzi, P
Meduri, G
Ficola, U
Calcagni, ML
Vaccaro, A
Rubini, G
Attard, M
Puma, ML
Ricci, R
Corsello, S
机构
[1] Univ Cattolica Sacro Cuore, Dept Nucl Med, I-00168 Rome, Italy
[2] Univ Cattolica Sacro Cuore, Dept Endocrinol, I-00168 Rome, Italy
[3] Cervello Hosp, Dept Nucl Med, Palermo, Italy
[4] Cervello Hosp, Dept Endocrinol, Palermo, Italy
[5] Univ Bari, Dept Nucl Med, Bari, Italy
[6] Univ Cattolica Sacro Cuore, Dept Pathol, I-00168 Rome, Italy
关键词
technetium-99m tetrofosmin; thallium-201; parathyroid scintigraphy; thyroid scintigraphy;
D O I
10.1007/s002590050467
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The: aim of the study was to quantitatively compare the scintigraphic images of the thyroid and abnormal parathyroid glands obtained with technetium-99m tetrofosmin and thallium-201 in patients with hyperparathyroidism. Forty-six patients with hyperparathyroidism underwent Tl-201 (74 MBq), Tc-99m-pertechnetate (74 MBq) and Tc-99m-tetrofosmin (555-740 MBq) scintigraphy in a single session. Image analysis included the computation of the thyroid/background ratio in the whole study population and the parathyroid/background ratio, parathyroid/thyroid ratio and diagnostic sensitivity in 17 patients who underwent parathyroid surgery. The pertechnetate subtraction technique was used. Tl-201 and Tc-99m-tetrofosmin showed a similar thyroid/background ratio (1.79+/-0.41 and 1.81+/-0.47, respectively, P=NS); however, Tc-99m-tetrofosmin showed a higher parathyroid/background ratio than Tl-201 (2.06+/-0.54 vs 1.79+/- 0.50, P=0.007). Despite the superior quality of Tc-99m-tetrofosmin images, both tracers showed identical sensitivity in detecting enlarged parathyroid glands in patients with primary hyperparathyroidism (89%) and in those with secondary hyperparathyroidism (50%).
引用
收藏
页码:907 / 911
页数:5
相关论文
共 15 条
[1]   Parathyroid scintigraphy: Comparison of technetium-99m methoxyisobutylisonitrile and technetium-99m tetrofosmin studies [J].
Aigner, RM ;
Fueger, GF ;
Nicoletti, R .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (06) :693-696
[2]  
Apostolopoulos DJ, 1998, J NUCL MED, V39, P1433
[3]  
Chen CC, 1997, J NUCL MED, V38, P834
[4]  
Fjeld JG, 1997, J NUCL MED, V38, P831
[5]  
GEATTI O, 1994, EUR J NUCL MED, V21, P17
[6]   Parathyroid imaging with Tc-99(m)-tetrofosmin [J].
Giordano, A ;
Meduri, G ;
Marozzi, P .
NUCLEAR MEDICINE COMMUNICATIONS, 1996, 17 (08) :706-710
[7]   Detection of an intrathymic parathyroid adenoma by Tc-99m tetrofosmin: A comparison with Tl-201 [J].
Giordano, A ;
Meduri, G ;
Corsello, SM ;
Pasquini, P .
CLINICAL NUCLEAR MEDICINE, 1996, 21 (12) :996-998
[8]   Differences between technetium-99m tetrofosmin and technetium-99m sestamibi in parathyroid scintigraphy [J].
Giordano, A ;
Meduri, G .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (03) :347-347
[9]  
GIORDANO A, 1998, EUR J NUCL MED, V25, P956
[10]  
GIORDANO A, 1995, NUCL MED COMMUN, V16, P223