Langmuir probe measurements of plasma parameters in a planar magnetron with additional plasma confinement

被引:30
|
作者
Spatenka, P
Vlcek, J
Blazek, J
机构
[1] Univ S Bohemia, Fac Biol Sci, Dept Math Phys & Chem, Ceske Budejovice 37005, Czech Republic
[2] Univ W Bohemia, Fac Sci Appl, Plzen 30614, Czech Republic
[3] Univ S Bohemia, Coll Educ, Ceske Budejovice 37115, Czech Republic
关键词
D O I
10.1016/S0042-207X(99)00144-X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Langmuir probe measurements have been carried out in a planar magnetron sputtering system with an additional plasma confinement which can be operated at low argon pressures (down to 3.4 x 10(-2) Pa) when target utilization greater than 80% can be achieved. The electron density, electron temperature, relative densities of low- and high-energy groups of electrons and the difference between the plasma and floating potential have been determined in various positions between the target and a substrate at the argon pressures in the range from 0.05 to 5 Pa. It has been proved that the additional magnetic field results, particularly in larger distances from the target at lower pressures, in the formation of structured electron energy distributions with a substantial contribution from a high-energy group of electrons, which is responsible for enhanced gas ionization and relatively high values observed for the difference between the plasma and the floating potential. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:165 / 170
页数:6
相关论文
共 50 条
  • [1] A comparison of internal plasma parameters in a conventional planar magnetron and a magnetron with additional plasma confinement
    Spatenka, P
    Leipner, I
    Vlcek, J
    Musil, J
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 1997, 6 (01): : 46 - 52
  • [2] Comparison of internal plasma parameters in a conventional planar magnetron and a magnetron with additional plasma confinement
    Spatenka, P.
    Leipner, I.
    Vicek, J.
    Musil, J.
    Plasma Sources Science and Technology, 1997, 6 (01): : 46 - 52
  • [3] PLANAR MAGNETRON WITH ADDITIONAL PLASMA-CONFINEMENT
    MUSIL, J
    RUSNAK, K
    JEZEK, V
    VLCEK, J
    VACUUM, 1995, 46 (04) : 341 - 347
  • [4] Plasma parameters measurements by means of Langmuir probe
    Mascali, D.
    Gambino, N.
    Miracoli, R.
    Gammino, S.
    Torrisi, L.
    Maimone, F.
    Tumino, L.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2008, 163 (4-6): : 471 - 478
  • [5] Correlation of target properties and plasma parameters in DC magnetron sputtering with Langmuir probe measurements
    Raggl, Stefan
    Postler, Johannes
    Winkler, Joerg
    Strauss, Georg
    Feist, Christian
    Plankensteiner, Arno
    Eidenberger-Schober, Michael
    Scheier, Paul
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2017, 35 (06):
  • [6] Simulation Inference of Plasma Parameters From Langmuir Probe Measurements
    Resendiz Lira, Pedro Alberto
    Marchand, Richard
    EARTH AND SPACE SCIENCE, 2021, 8 (03)
  • [7] LANGMUIR PROBE MEASUREMENTS OF AXIAL VARIATION OF PLASMA PARAMETERS IN 27.1 MHZ RF OXYGEN PLANAR DISCHARGES
    SABADIL, H
    KLAGGE, S
    KAMMEYER, M
    PLASMA CHEMISTRY AND PLASMA PROCESSING, 1988, 8 (04) : 425 - 444
  • [8] The impact of medium frequency pulsed magnetron discharge power on the single probe Langmuir measurements and resulted plasma parameters
    Wiatrowski, A.
    Posadowski, W. M.
    MATERIALS SCIENCE-POLAND, 2016, 34 (02): : 374 - 385
  • [9] LANGMUIR PROBE MEASUREMENTS IN A CESIUM PLASMA
    HOLSCHER, JG
    GELTEN, MJ
    APPLIED SCIENTIFIC RESEARCH, 1967, 18 (03): : 167 - &
  • [10] Langmuir probe measurements in plasma shadows
    Waldmann, O
    Koch, B
    Fussmann, G
    PLASMA 2005, 2006, 812 : 443 - +