Which device should be considered the best for lung isolation: double-lumen endotracheal tube versus bronchial blockers

被引:113
作者
Campos, Javier H. [1 ]
机构
[1] Univ Iowa, Roy J & Lucille A Carver Coll Med, 200 Hawkins Dr, Iowa City, IA 52242 USA
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
bronchial blockers; double-lumen endotracheal tubes; fiberoptic bronchoscopy; lung isolation techniques;
D O I
10.1097/ACO.0b013e3280111e2a
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose of review This review is a clinical comparison between double-lumen endotracheal tubes and bronchial blockers to determine which device is considered the best for lung isolation. Recent findings Double-lumen endotracheal tubes and bronchial blockers have been found to be clinically equivalent in terms of performance in providing lung collapse for patients with normal airways. In the last five years, however, numerous reports have indicated a preference for the use of bronchial blockers in patients with airway abnormalities. For nonthoracic anesthesiologists who have limited experience in thoracic anesthesia cases, none of the devices (double-lumen tubes or bronchial blockers) have been shown to provide any advantage while in use due to a high incidence of unrecognized malpositions. Overall, each device provides advantages depending upon the case, such as absolute lung separation with a double-lumen endotracheal tube or the use of a bronchial blocker in a difficult airway for a patient requiring lung isolation. Summary Double-lumen endotracheal tubes and bronchial blockers should be part of the armamentarium of every anesthesiologist involved in lung isolation techniques and every device should be tailored to specific case needs.
引用
收藏
页码:27 / 31
页数:5
相关论文
共 34 条
[11]   A comparison of a left-sided Broncho-Cath® with the torque control blocker univent and the wire-guided blocker [J].
Campos, JH ;
Kernstine, KH .
ANESTHESIA AND ANALGESIA, 2003, 96 (01) :283-289
[12]   Is there a better right-sided tube for one-lung ventilation? A comparison of the right-sided double-lumen tube with the single-lumen tube with right-sided enclosed bronchial blocker [J].
Campos, JH ;
Massa, FC .
ANESTHESIA AND ANALGESIA, 1998, 86 (04) :696-700
[13]  
Campos JH, 2002, ANESTHESIOLOGY, V97, P1295
[14]   Pro: Right-sided double-lumen endotracheal tubes should be routinely used in thoracic surgery [J].
Campos, JH ;
Gomez, MN .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (02) :246-248
[15]   Effects on oxygenation during selective lobar versus total lung collapse with or without continuous positive airway pressure [J].
Campos, JH .
ANESTHESIA AND ANALGESIA, 1997, 85 (03) :583-586
[16]  
Cohen E, 2005, ANESTH ANALG, V101, P1877, DOI [10.1213/O1.ANE.0000184116.86888.D9, 10.1213/01.ANE.0000184116.86888.D9]
[17]   Sequential one-lung isolation using a double Arndt bronchial blocker technique [J].
Culp, WC ;
Kinsky, MP .
ANESTHESIA AND ANALGESIA, 2004, 99 (03) :945-946
[18]   Airway rupture from double-lumen tubes [J].
Fitzmaurice, BG ;
Brodsky, JB .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1999, 13 (03) :322-329
[19]  
Fortier G, 2001, CAN J ANAESTH, V48, P790, DOI 10.1007/BF03016696
[20]   Use of the Arndt wire-guided endobronchial blocker via nasal for one-tung ventilation in patient with anticipated restricted mouth opening for esophagectomy [J].
Ho, CYA ;
Chen, CY ;
Yang, MW ;
Liu, HP .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 28 (01) :174-175