Hydrodynamic Chromatography

被引:112
作者
Striegel, Andre M. [1 ]
Brewer, Amandaa K. [2 ]
机构
[1] NIST, Div Analyt Chem, Gaithersburg, MD 20899 USA
[2] Tosoh Biosci LLC, King Of Prussia, PA 19406 USA
来源
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 5 | 2012年 / 5卷
关键词
multiple detection; particle sizing; polymer characterization; chromatography fundamentals; packed-column HDC; microcapillary HDC; SIZE-EXCLUSION CHROMATOGRAPHY; GEL PERMEATION CHROMATOGRAPHY; FIELD-FLOW FRACTIONATION; PACKED-COLUMNS; SEPARATION; POLYMER; MACROMOLECULES; DEGRADATION; PARTICLES; SILICA;
D O I
10.1146/annurev-anchem-062011-143107
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrodynamic chromatography (HDC) has experienced a resurgence in recent years for particle and polymer characterization, principally because of its coupling to a multiplicity of physical detection methods. When coupled to light scattering (both multiangle static and quasi-elastic), viscometric, and refractometric detectors, HDC can determine the molar mass, size, shape, and structure of colloidal analytes continuously and as a function of one another, all in a single analysis. In so doing, it exposes the analytes to less shear force (and, hence, less potential for flow-induced degradation) than in, for instance, size-exclusion chromatography. In this review, we discuss the fundamental chromatographic underpinnings of this technique in terms of retention, band broadening, and resolution, and we describe the power of multidetector HDC with examples from the recent literature.
引用
收藏
页码:15 / 34
页数:20
相关论文
共 45 条
[1]   A REVIEW OF POLYMER SHEAR DEGRADATION IN SIZE-EXCLUSION CHROMATOGRAPHY [J].
BARTH, HG ;
CARLIN, FJ .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1984, 7 (09) :1717-1738
[2]  
Bos J., 1995, CHROMATOGRAPHY PETRO, P95
[3]  
Brewer AK, 2010, THESIS FLORIDA STATE
[4]   Characterizing String-of-Pearls Colloidal Silica by Multidetector Hydrodynamic Chromatography and Comparison to Multidetector Size-Exclusion Chromatography, Off-Line Multiangle Static Light Scattering, and Transmission Electron Microscopy [J].
Brewer, Amandaa K. ;
Striegel, Andre M. .
ANALYTICAL CHEMISTRY, 2011, 83 (08) :3068-3075
[5]   Characterizing a spheroidal nanocage drug delivery vesicle using multi-detector hydrodynamic chromatography [J].
Brewer, Amandaa K. ;
Striegel, Andre M. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (04) :1507-1514
[6]   Characterizing the size, shape, and compactness of a polydisperse prolate ellipsoidal particle via quadruple-detector hydrodynamic chromatography [J].
Brewer, Amandaa K. ;
Striegel, Andre M. .
ANALYST, 2011, 136 (03) :515-519
[7]   Hydrodynamic chromatography of latex blends [J].
Brewer, Amandaa K. ;
Striegel, Andre M. .
JOURNAL OF SEPARATION SCIENCE, 2010, 33 (22) :3555-3563
[8]   Particle size characterization by quadruple-detector hydrodynamic chromatography [J].
Brewer, Amandaa K. ;
Striegel, Andre M. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (01) :295-302
[9]  
Burchard W, 1999, ADV POLYM SCI, V143, P113
[10]  
DiMarzio E.A., 1970, MACROMOLECULES, V3, P131, DOI [DOI 10.1021/MA60014A005, 10.1021/ma60014a005]