Routes for the production of isotopes for PET with high intensity deuteron accelerators

被引:5
作者
Arias de Saavedra, F. [1 ]
Porras, I. [1 ]
Praena, J. [1 ]
机构
[1] Univ Granada, Fac Ciencias, Dept Fis Atom Mol & Nucl, E-18071 Granada, Spain
关键词
Radioisotopes; PET; Deuterons; Linear accelerator; BLOOD-FLOW; C-12(D; N)N-13;
D O I
10.1016/j.nima.2018.01.048
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recent advances in accelerator science are opening new possibilities in different fields of physics. In particular, the development of compact linear accelerators that can provide charged particles of low-medium energy (few MeV) with high current (above mA) allows for the study of new possibilities in neutron production and for new routes for the production of radioisotopes. Keeping in mind how radioisotopes are actually produced in dedicated facilities, we have performed a study of alternative reactions to produce PET isotopes induced by low energy deuterons. We have fitted the EXFOR cross sections data, used the fitted values of the stopping power by Andersen and Ziegler and calculated by numerical integration the production rate of isotopes for charged particles up to 20 MeV. The results for deuterons up to 3 MeV are compared with the ones from cyclotrons, which are able to provide higher energies to the charged projectiles but with lower intensities. Our results indicate that using linear accelerators may be a good alternative for producing PET isotopes, reducing the problem of neutron activation. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:50 / 53
页数:4
相关论文
共 20 条
[1]  
Andersen H. H., 1985, HYDROGEN STOPPING PO
[2]   A 50-kW prototype of the high-power production target for the FRIB [J].
Avilov, Mikhail ;
Fadeev, Sergey ;
Fernandes, Sandrina ;
Golkovsky, Mikhail ;
Mittig, Wolfgang ;
Pellemoine, Frederique ;
Schein, Mike .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 305 (03) :817-823
[3]   16O ANALOGUE STATES IN 15N(P,N) 15O REACTION [J].
BARNETT, AR .
NUCLEAR PHYSICS A, 1968, A120 (02) :342-&
[4]   QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW INVIVO WITH (H2O)-O-15 [J].
BERGMANN, SR ;
FOX, KAA ;
RAND, AL ;
MCELVANY, KD ;
WELCH, MJ ;
MARKHAM, J ;
SOBEL, BE .
CIRCULATION, 1984, 70 (04) :724-733
[5]  
Bracco A., 2014, NUPECC REPORTS
[6]   Thick target for high-power ISOL facilities [J].
Bricault, Pierre G. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 376 :3-7
[7]  
FENYVESI A, 1997, C NUCL DATA SCI, V59, P1707
[8]  
FIROUZBAKHT ML, 1991, RADIOCHIM ACTA, V55, P1
[9]  
Hess E, 2001, RADIOCHIM ACTA, V89, P357, DOI 10.1524/ract.2001.89.6.357
[10]  
Hildebrand F. B., 1987, INTRO NUMERICAL ANAL, P93