Biomechanical Analysis of the Modified Kessler, Lahey, Adelaide, and Becker Sutures for Flexor Tendon Repair

被引:18
作者
Jordan, Martin C. [1 ]
Schmitt, Vanessa [1 ]
Jansen, Hendrik [1 ]
Meffert, Rainer H. [1 ]
Hoelscher-Doht, Stefanie [1 ]
机构
[1] Univ Hosp, Dept Trauma Hand Plast & Reconstruct Surg, D-97080 Wurzburg, Germany
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2015年 / 40卷 / 09期
关键词
4-strand repair; hand; reconstruction; suture; tendon; LOCKING; STRENGTH; SURGERY; TENSION; GAP;
D O I
10.1016/j.jhsa.2015.05.032
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To compare the biomechanical properties of the modified Kessler, Lahey, Adelaide, and Becker repairs, which are marked by either a locking-loop or a cross-lock configuration. Methods Ninety-six lacerated porcine flexor tendons were repaired using the respective core suture and an epitendinous repair. Biomechanical testing was conducted under static and cyclic loads. Parameters of interest were 2-mm gap formation force, displacement during different loads, stiffness, maximum force, and mode of failure. Results The meaningful gap formation occurred in all 4 repairs at similar tension loads without any significant differences. Maximum force was highest in the Becker repair with a considerable difference compared with the modified Kessler and Lahey sutures. The Adelaide repair showed the highest stiffness. Overall, the displacement during cyclic loading demonstrated similar results with an exception between the Lahey and the Adelaide repairs at 10 N load. Failure by suture pull-out occurred in 42% in the modified Kessler, in 38% in the Lahey, and in 4% in the Adelaide repairs. The Becker repair failed only by suture rupture. Conclusions The results of our study suggest that the difference between the 4-strand repairs with a cross-lock or-a locking-loop configuration is minor in regard to gap formation. A strong epitendinous suture and the application of core suture pretension might prevent differences in gapping. However, the modified Kessler and Lahey repairs had an inferior maximum tensile strength and were prone to early failure caused :by the narrow locking loops with their limited locking power. Clinical relevance We suggest that surgeons should use pre-tension in repaired tendons to improve gap resistance and should avoid narrow locking loop anchoring to the tendon. Copyright (C) 2015 by the American Society for Surgery of the Hand. All rights reserved.
引用
收藏
页码:1812 / 1817
页数:6
相关论文
共 30 条
[1]   Repair of zone II flexor digitorum profundus lacerations using varying suture sizes: A comparative biomechanical study [J].
Alavanja, G ;
Dailey, E ;
Mass, DP .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (03) :448-454
[2]   Biomechanical and histologic characteristics of canine flexor tendon repair using early postoperative mobilization [J].
Aoki, M ;
Kubota, H ;
Pruitt, DL ;
Manske, PR .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1997, 22A (01) :107-114
[3]   ELIMINATING GAP IN FLEXOR TENDON SURGERY - NEW METHOD OF SUTURE [J].
BECKER, H ;
DAVIDOFF, M .
HAND, 1977, 9 (03) :306-311
[4]  
Becker H, 1979, J Hand Surg Am, V4, P454
[5]   Comparative biomechanic performances of locked Cruciate four-strand flexor tendon repairs in an ex vivo porcine model [J].
Croog, Alexander ;
Goldstein, Rachel ;
Nasser, Philip ;
Lee, Steve K. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (02) :225-232
[6]   Optimizing biomechanical performance of the 4-strand cruciate flexor tendon repair [J].
Dona, E ;
Gianoutsos, MP ;
Walsh, WR .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2004, 29A (04) :571-580
[7]  
Gelberman R H, 1985, Hand Clin, V1, P35
[8]   MECHANICAL ANALYSIS OF TENDON SUTURE TECHNIQUES [J].
GREENWALD, DP ;
HONG, HZ ;
MAY, JW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1994, 19A (04) :641-647
[9]  
Hatanaka H, 2000, CLIN ORTHOP RELAT R, P267
[10]   The Effects of Core Suture Purchase on the Biomechanical Characteristics of a Multistrand Locking Flexor Tendon Repair: A Cadaveric Study [J].
Lee, Steve K. ;
Goldstein, Rachel Y. ;
Zingman, Alissa ;
Terranova, Carl ;
Nasser, Philip ;
Hausman, Michael R. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (07) :1165-1171