Electrochemical/Microstructural Studies on the Corrosion of Prestressed Steel Strand in Concrete with Naturally Ingressing Chlorides

被引:1
作者
Joseline, Dyana [1 ]
Pillai, Radhakrishna G. [1 ]
机构
[1] Indian Inst Technol Madras, Dept Civil Engn, Chennai 600036, Tamil Nadu, India
关键词
chlorides; concrete; corrosion; environmentally assisted cracking; pearlitic; prestress; steel; strand; HYDROGEN EMBRITTLEMENT SUSCEPTIBILITY; ASSISTED STRESS-CORROSION; REINFORCED-CONCRETE; POLARIZATION RESISTANCE; RESIDUAL-STRESSES; COLD-DRAWN; CRACKING; STRENGTH; FRACTURES; BEHAVIOR;
D O I
10.5006/4013
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The occurrence of environmentally assisted cracking (EAC) is as dependent on the aggressiveness of the environment as the susceptibility of the material and the presence of static tensile stresses. However, the influence of the environment has not been adequately considered in past investigations on EAC mechanisms of prestressing strands. This study utilizes various characterization techniques to evaluate the surface/bulk deterioration of corroded pretensioned concrete (PTC) specimens after natural chloride exposure (by diffusion through cover concrete). Corroded strands in two PTC prism specimens (3,000 mm x 150 mm x 200 mm) were characterized using electrochemical impedance spectroscopy (EIS) and other microanalytical techniques. The EIS and scanning electron microscope (SEM) images obtained after 1 y and 2 y of exposure revealed a negligible residual protectiveness of the passivated surface (although the concretes possessed high resistivity). Raman spectra, SEM, and x-ray computed tomography images of extracted corroded strands also provided unique insights into the pattern of corrosion propagation in PTC systems subjected to realistic chloride exposure. Microcracks in the bulk metal beneath flatbottomed corrosion pits revealed the possible EAC at low chloride levels expected in service (<0.6% by weight of binder). The findings serve as a basis to define chloride-induced passive-to-active transition as the end of risk-free service life of PTC structures, and for considering it as the limit state for both service life design and corrosion assessment to avoid the onset of EAC.
引用
收藏
页码:1126 / 1142
页数:17
相关论文
共 75 条
[21]   Effects of hydrogen assisted stress corrosion on damage tolerance of a high-strength duplex stainless steel wire for prestressing concrete [J].
de Abreu, M. ;
Iordachescu, M. ;
Valiente, A. .
CONSTRUCTION AND BUILDING MATERIALS, 2014, 66 :38-44
[22]   Electrochemical behaviour of steel in mortar and in simulated pore solutions: Analogies and differences [J].
Duffo, Gustavo S. ;
Farina, Silvia B. .
CEMENT AND CONCRETE RESEARCH, 2016, 88 :211-216
[23]   A critical-strain criterion for hydrogen embrittlement of cold-drawn, ultrafine pearlitic steel [J].
Enos, DG ;
Scully, JR .
METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2002, 33 (04) :1151-1166
[24]   ON-SITE DETECTION OF CORROSION IN REINFORCED-CONCRETE STRUCTURES [J].
GONZALEZ, JA ;
FELIU, S ;
ANDRADE, C ;
RODRIGUEZ, I .
MATERIALS AND STRUCTURES, 1991, 24 (143) :346-350
[25]  
Gu P., ACI MATER J, V94
[26]  
Hansson C.M., 2012, THE MASTERBUILDER
[27]   INFLUENCE OF POTENTIAL, CHLORIDES, PH, AND PRECHARGING TIME ON EMBRITTLEMENT OF CATHODICALLY POLARIZED PRESTRESSING STEEL [J].
HARTT, WH ;
KUMRIA, CC ;
KESSLER, RJ .
CORROSION, 1993, 49 (05) :377-385
[28]   Microstructure, Durability and Mechanical Properties of Mortars Prepared Using Ternary Binders with Addition of Slag, Fly Ash and Limestone [J].
Ibanez-Gosalvez, Javier ;
Real-Herraiz, Teresa ;
Marcos Ortega, Jose .
APPLIED SCIENCES-BASEL, 2021, 11 (14)
[29]   Corrosion reaction and hydrogen absorption of steel for prestressed concrete in a 20 mass% ammonium thiocyanate solution [J].
Ichiba, Mikiyuki ;
Sakai, Jun'ichi ;
Doshida, Tomoki ;
Takai, Kenichi .
SCRIPTA MATERIALIA, 2015, 102 :59-62
[30]  
Joseline D., 2021, THESIS INDIAN I TECH