Beamline I511 at MAX II, capabilities and performance

被引:134
作者
Denecke, R
Väterlein, P
Bässler, M
Wassdahl, N
Butorin, S
Nilsson, A
Rubensson, JE
Nordgren, J
Mårtensson, N
Nyholm, R
机构
[1] Univ Uppsala, Dept Phys, S-75121 Uppsala, Sweden
[2] Univ Lund, Max Lab, S-22100 Lund, Sweden
关键词
soft X-ray monochromator; beam waist; soft X-ray emission spectroscopy;
D O I
10.1016/S0368-2048(98)00358-2
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The new undulator beamline I511 at MAX-lab, now under commissioning, has been optimized for X-ray emission and photoelectron spectroscopies. Using an SX-700 high flux monochromator the accessible photon energy range is from 90 eV to about 1500 eV. The performance of the undulator agrees very well with the specifications, as shown by measurements using a photodiode. The energy resolution of the monochromator has been checked using absorption measurements in a gas cell. It was found to meet the expectations and exceeds a resolving power of 10 000 at 244 eV. The photon flux as a function of energy has been recorded as well and gives a maximum flux of 3x10(13) photons/s/100 mA/0.1% BW. Beamlines I511 and I411 will be the first synchrotron beamlines making use of a so-called beam waist phenomenon, known from laser physics. We show results of ray-tracing calculations to determine the ultimate spot size on the sample location. The endstations to be used at this new beamline and their capabilities will be discussed as an example of the future use of this facility. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:971 / 977
页数:7
相关论文
共 14 条
[1]  
AKSELA S, 1991, MAX PUBLICATION
[2]   THE MAX-II SYNCHROTRON-RADIATION STORAGE-RING [J].
ANDERSSON, A ;
ERIKSSON, M ;
LINDGREN, LJ ;
ROJSEL, P ;
WERIN, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 343 (2-3) :644-649
[3]   THE NEW 1.5-GEV STORAGE-RING FOR SYNCHROTRON-RADIATION - MAX-II [J].
ANDERSSON, A ;
ERIKSSON, M ;
LINDGREN, LJ ;
ROJSEL, P ;
WERIN, S .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1850-1853
[4]  
DELRIO MS, 1997, SPIE P, V3152, P148
[5]   PERFORMANCE OF THE HIGH-RESOLUTION SX700/II MONOCHROMATOR [J].
DOMKE, M ;
MANDEL, T ;
PUSCHMANN, A ;
XUE, C ;
SHIRLEY, DA ;
KAINDL, G ;
PETERSEN, H ;
KUSKE, P .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :80-89
[6]   END STATION FOR POLARIZATION AND EXCITATION-ENERGY SELECTIVE SOFT-X-RAY FLUORESCENCE SPECTROSCOPY [J].
GUO, JH ;
WASSDAHL, N ;
SKYTT, P ;
BUTORIN, SM ;
DUDA, LC ;
ENGLUND, CJ ;
NORDGREN, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1561-1563
[7]   SHADOW - A SYNCHROTRON RADIATION RAY TRACING PROGRAM [J].
LAI, B ;
CERRINA, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :337-341
[8]  
LEBLANC G, 1996, P EPAC
[9]   Coherent and incoherent processes in resonant photoemission [J].
Martensson, N ;
Weinelt, M ;
Karis, O ;
Magnuson, M ;
Wassdahl, N ;
Nilsson, A ;
Stohr, J ;
Samant, M .
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1997, 65 (02) :159-167
[10]   SOFT-X-RAY EMISSION-SPECTROSCOPY USING MONOCHROMATIZED SYNCHROTRON RADIATION [J].
NORDGREN, J ;
BRAY, G ;
CRAMM, S ;
NYHOLM, R ;
RUBENSSON, JE ;
WASSDAHL, N .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1690-1696