Comparison of a New Refractive Multifocal Intraocular Lens with an Inferior Segmental Near Add and a Diffractive Multifocal Intraocular Lens

被引:86
作者
Alio, Jorge L. [1 ,2 ]
Plaza-Puche, Ana B. [1 ]
Javaloy, Jaime [1 ,2 ]
Jose Ayala, Maria [1 ]
Moreno, Luis J. [1 ,2 ]
Pinero, David P. [3 ]
机构
[1] Vissum Corp, Alicante, Spain
[2] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
[3] Univ Alicante, Dept Opt Farmacol & Anat, Alicante, Spain
关键词
WAVE-FRONT ANALYSIS; OPTICAL-PERFORMANCE; CONTRAST SENSITIVITY; READING PERFORMANCE; CLINICAL-OUTCOMES; BILATERAL REZOOM; IMAGE QUALITY; RESTOR; ABERRATIONS; IMPLANTATION;
D O I
10.1016/j.ophtha.2011.08.036
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the visual acuity outcomes and ocular optical performance of eyes implanted with a multifocal refractive intraocular lens (IOL) with an inferior segmental near add or a diffractive multifocal IOL. Design: Prospective, comparative, nonrandomized, consecutive case series. Participants: Eighty-three consecutive eyes of 45 patients (age range, 36-82 years) with cataract were divided into 2 groups: group A, 45 eyes implanted with Lentis Mplus LS-312 (Oculentis GmbH, Berlin, Germany); group B, 38 eyes implanted with diffractive IOL Acri.Lisa 366D (Zeiss, Oberkochen, Germany). Methods: All patients underwent phacoemulsification followed by IOL implantation in the capsular bag. Distance corrected, intermediate, and near with the distance correction visual acuity outcomes and contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively during a 3-month follow-up. Main Outcome Measures: Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), corrected distance near and intermediate visual acuity (CDNVA), contrast sensitivity, intraocular aberrations, and defocus curve. Results: A significant improvement in UDVA, CDVA, and UNVA was observed in both groups after surgery (P <= 0.04). Significantly better values of UNVA (P<0.01) and CDNVA (P<0.04) were found in group B. In the defocus curve, significantly better visual acuities were present in eyes in group A for intermediate vision levels of defocus (P <= 0.04). Significantly higher amounts of postoperative intraocular primary coma and spherical aberrations were found in group A (P<0.01). In addition, significantly better values were observed in photopic contrast sensitivity for high spatial frequencies in group A (P <= 0.04). Conclusions: The Lentis Mplus LS-312 and Acri. Lisa 366D IOLs are able to successfully restore visual function after cataract surgery. The Lentis Mplus LS-312 provided better intermediate vision and contrast sensitivity outcomes than the Acri. Lisa 366D. However, the Acri. Lisa design provided better distance and near visual outcomes and intraocular optical performance parameters. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. Ophthalmology 2012;119:555-563 (C) 2012 by the American Academy of Ophthalmology.
引用
收藏
页码:555 / 563
页数:9
相关论文
共 49 条
[1]   Prospective visual evaluation of apodized diffractive intraocular lenses [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Baamonde, M. Begona ;
Mont-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (07) :1235-1243
[2]   Visual acuity comparison of 2 models of bifocal aspheric intraocular lenses [J].
Alfonso, Jose F. ;
Puchades, Cristina ;
Fernandez-Vega, Luis ;
Montes-Mico, Robert ;
Valcarcel, Beatriz ;
Ferrer-Blasco, Teresa .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04) :672-676
[3]   Crystalline lens optical dysfunction through aging [J].
Alió, JL ;
Schimchak, P ;
Negri, HP ;
Montés-Micó, R .
OPHTHALMOLOGY, 2005, 112 (11) :2022-2029
[4]   Retinal image quality after microincision intraocular lens implantation [J].
Alió, JL ;
Schimchak, P ;
Montés-Micó, R ;
Galal, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (08) :1557-1560
[5]   Near vision restoration with refractive lens exchange and pseudoaccommodating and multifocal refractive and diffractive intraocular lenses -: Comparative clinical study [J].
Alió, JL ;
Tavolato, M ;
De la Hoz, F ;
Claramonte, P ;
Rodríguez-Prats, JL ;
Galal, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (12) :2494-2503
[6]   Microincision multifocal intraocular lens with and without a capsular tension ring -: Optical quality and clinical outcomes [J].
Alio, Jorge L. ;
Elkady, Bassam ;
Ortiz, Dolores ;
Bernabeu, Gonzalo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) :1468-1475
[7]   Clinical outcomes and intraocular optical quality of a diffractive multifocal intraocular lens with asymmetrical light distribution [J].
Alio, Jorge L. ;
Elkady, Bassarn ;
Ortiz, Dolores ;
Bernabeu, Gonzalo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (06) :942-948
[8]   Design of short Spanish sentences for measuring reading performance:: Radner-Vissum test [J].
Alio, Jorge L. ;
Radner, Wolfgang ;
Plaza-Puche, Ana B. ;
Ortiz, Dolores ;
Carmen Neipp, M. ;
Jose Quiles, M. ;
Rodriguez-Marin, Jesus .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (04) :638-642
[9]   Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens [J].
Alio, Jorge L. ;
Pinero, David P. ;
Plaza-Puche, Ana B. ;
Joanna Rodriguez, Maria .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02) :241-250
[10]   Visual and Optical Performance With Two Different Diffractive Multifocal Intraocular Lenses Compared to a Monofocal Lens [J].
Alio, Jorge L. ;
Pinero, David P. ;
Plaza-Puche, Ana B. ;
Amparo, Francisco ;
Jimenez, Ramon ;
Rodriguez-Prats, Jose L. ;
Javaloy, Jaime .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (08) :570-581