Path length resolved Doppler measurements of multiple scattered photons in turbid media for various absorptions using phase modulated low-coherence interferometry

被引:1
作者
Varghese, Babu [1 ,2 ]
Rajan, Vinayakrishnan [1 ,2 ]
Van Leeuwen, Ton G. [1 ,2 ]
Steenbergen, Wiendelt [1 ,2 ]
机构
[1] Univ Twente, Biomed Technol Inst, Biophys Engn Grp, POB 217, NL-7500 AE Enschede, Netherlands
[2] Acad Med Ctr, Laser Ctr, NL-1105 AZ Amsterdam, Netherlands
来源
BIOPHOTONICS AND NEW THERAPY FRONTIERS | 2006年 / 6191卷
关键词
light scattering; low coherence; interferometry; laser Doppler;
D O I
10.1117/12.661618
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We report the development of non-invasive, path length resolved Doppler measurements of the multiply scattered light in turbid media, for different absorptions using phase modulated Mach-Zehnder low coherence interferometer, with separate fibers for illumination and detection. A Doppler broadened phase modulation interference peak is observed that shows an increase in the average Doppler shift with optical path length, independent of absorption. The estimated path length distributions indicate suppression and narrowing for increasing absorption and can be related by Lambert-Beer's law.
引用
收藏
页数:8
相关论文
共 10 条
[1]   COMPARISON OF TIME-RESOLVED AND TIME-UNRESOLVED MEASUREMENTS OF DEOXYHEMOGLOBIN IN BRAIN [J].
CHANCE, B ;
LEIGH, JS ;
MIYAKE, H ;
SMITH, DS ;
NIOKA, S ;
GREENFELD, R ;
FINANDER, M ;
KAUFMANN, K ;
LEVY, W ;
YOUNG, M ;
COHEN, P ;
YOSHIOKA, H ;
BORETSKY, R .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1988, 85 (14) :4971-4975
[2]   OPTICAL-PROPERTIES OF INTRALIPID - A PHANTOM MEDIUM FOR LIGHT-PROPAGATION STUDIES [J].
FLOCK, ST ;
JACQUES, SL ;
WILSON, BC ;
STAR, WM ;
VANGEMERT, MJC .
LASERS IN SURGERY AND MEDICINE, 1992, 12 (05) :510-519
[3]   A CONTINUOUSLY VARIABLE FREQUENCY CROSS-CORRELATION PHASE FLUOROMETER WITH PICOSECOND RESOLUTION [J].
GRATTON, E ;
LIMKEMAN, M .
BIOPHYSICAL JOURNAL, 1983, 44 (03) :315-324
[4]  
KOSTADINKA K, 1998, PHYS REV E, P58
[5]   SIGNAL PROCESSOR FOR LASER DOPPLER TISSUE FLOWMETERS [J].
NILSSON, GE .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1984, 22 (04) :343-348
[6]   Effects of absorption on coherence domain path length resolved dynamic light scattering in the diffuse regime [J].
Petoukhova, AL ;
Steenbergen, W ;
van Leeuwen, TG ;
de Mul, FFM .
APPLIED PHYSICS LETTERS, 2002, 81 (04) :595-597
[7]   Path-length distribution and path-length-resolved Doppler measurements of multiply scattered photons by use of low-coherence interferometry [J].
Petoukhova, AL ;
Steenbergen, W ;
de Mul, FFM .
OPTICS LETTERS, 2001, 26 (19) :1492-1494
[8]  
POPESCU G, 1999, OPT LETT, P24
[9]  
SHEPHERD P, 1990, LASER DOPPLER BLOOD
[10]   Path-length-resolved dynamic light scattering: modeling the transition from single to diffusive scattering [J].
Wax, A ;
Yang, CH ;
Dasari, RR ;
Feld, MS .
APPLIED OPTICS, 2001, 40 (24) :4222-4227