The Effect of Attenuation and Scatter Correction in Rat Brain PET

被引:6
作者
Yu, A. Ram [1 ,2 ]
Kim, Jin Su [1 ]
Moon, Jisook [3 ]
Kim, Hee Joung [2 ]
Lim, Sang Moo [1 ]
Kim, Kyeong Min [1 ]
机构
[1] Korea Inst Radiol & Med Sci, Mol Imaging Res Ctr, Seoul 139706, South Korea
[2] Yonsei Univ, Dept Radiol Sci, Coll Hlth Sci, Wonju 220710, South Korea
[3] CHA Univ, Dept Appl Biomed Sci, Coll Life Sci, Seoul 135081, South Korea
关键词
Attenuation correction; brain PET; positron emission tomography; scatter correction; SPECT; MODEL;
D O I
10.1109/TNS.2012.2230338
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Attenuation correction (AC) and scatter correction (SC) are problematic issues for animal positron emission tomography (PET). In this study, the effects of AC and SC were assessed using PET on a phantom and actual rat brain. Transmission (TX) was performed using Co-57 for 15 min. After a 15 min TX scan, emission (EM) PET was performed in list mode for 1 h. To assess the effects of AC and SC, the spillover ratio (SOR) was measured using a rat-sized NEMA NU4 image-quality phantom; statistical parametric mapping (SPM) was performed to assess the effects of AC and SC in the rat brain using F-18-FDG (FDG). In addition, the binding potential (BP) was compared for F-18-FP-CIT (FP-CIT) PET. SPM was used to compare PET images to which AC and SC were applied, and BP was used for FP-CIT PET. The SORs of air and water decreased after AC and SC. SPM for FDG PET after AC showed a significant increase in FDG-measured activity in the cerebellum and occipital cortex. After AC/SC, a significant decrease in FDG-measured activity was observed in the frontal and temporal cortices. For FP-CIT PET of the rat brain, the BP decreased by 26% after AC because the FP-CIT uptake increased more in the cerebellum than in the striatum owing to AC. After AC and SC, the mean BP increased by 61%. AC and AC/SC were found to be necessary components of the artifact correction process for both FDG PET and FP-CIT PET of rat brains.
引用
收藏
页码:751 / 757
页数:7
相关论文
共 28 条
[1]  
Alexoff DL, 2003, J NUCL MED, V44, P815
[2]   Transmission scanning in emission tomography [J].
Bailey, DL .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (07) :774-787
[3]   Performance Evaluation of the Inveon Dedicated PET Preclinical Tomograph Based on the NEMA NU-4 Standards [J].
Bao, Qinan ;
Newport, Danny ;
Chen, Mu ;
Stout, David B. ;
Chatziioannou, Arion F. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (03) :401-408
[4]   PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients [J].
Burger, C ;
Goerres, G ;
Schoenes, S ;
Buck, A ;
Lonn, AHR ;
von Schulthess, GK .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (07) :922-927
[5]   Attenuation correction for small animal PET tomographs [J].
Chow, PL ;
Rannou, FR ;
Chatziioannou, AF .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (08) :1837-1850
[6]  
DAUBEWITHERSPOON ME, 1987, J NUCL MED, V28, P1717
[7]   CHRONIC EFFECTS OF SINGLE INTRASTRIATAL INJECTIONS OF 6-HYDROXYDOPAMINE OR 1-METHYL-4-PHENYLPYRIDINIUM STUDIED BY MICRODIALYSIS IN FREELY MOVING RATS [J].
ESPINO, A ;
CUTILLAS, B ;
TORTOSA, A ;
FERRER, I ;
BARTRONS, R ;
AMBROSIO, S .
BRAIN RESEARCH, 1995, 695 (02) :151-157
[8]   NEMA NU 2-2007 performance measurements of the Siemens Inveon™ preclinical small animal PET system [J].
Kemp, Brad J. ;
Hruska, Carrie B. ;
McFarland, Aaron R. ;
Lenox, Mark W. ;
Lowe, Val J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (08) :2359-2376
[9]   Assessment of cerebral glucose metabolism in cat deafness model: Strategies for improving the voxel-based statistical analysis for animal PET studies [J].
Kim, Jin Su ;
Lee, Jae Sung ;
Park, Min-Hyun ;
Kang, Hyejin ;
Lee, Jong Jin ;
Lee, Hyo-Jeong ;
Im, Ki Chun ;
Moon, Dae Hyuk ;
Lim, Sang-Moo ;
Oh, Seung-Ha ;
Lee, Dong Soo .
MOLECULAR IMAGING AND BIOLOGY, 2008, 10 (03) :154-161
[10]   Validation of a postinjection transmission method for actual rat brain PET [J].
Kim, Jin Su ;
Yu, A. Ram ;
Kim, Kyeong Min ;
Oh, Seung Jun ;
Ryu, Jin Sook ;
Kim, Hee-Joung ;
Lim, Sang Moo .
MEDICAL PHYSICS, 2012, 39 (09) :5614-5620