Evaluation of an automated deformable image matching method for quantifying lung motion in respiration-correlated CT images

被引:54
作者
Pevsner, A [1 ]
Davis, B
Joshi, S
Hertanto, A
Mechalakos, J
Yorke, E
Rosenzweig, K
Nehmeh, S
Erdi, YE
Humm, JL
Larson, S
Ling, CC
Mageras, GS
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
[2] Univ N Carolina, Dept Comp Sci, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Dept Radiat Oncol, Chapel Hill, NC 27599 USA
[4] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10021 USA
[5] Mem Sloan Kettering Canc Ctr, Dept Radiol, New York, NY 10021 USA
关键词
deformable image registration; radiation treatment planning; respiration; respiration-correlated CT; lung cancer;
D O I
10.1118/1.2161408
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have evaluated an automated registration procedure for predicting tumor and lung deformation based on CT images of the thorax obtained at different respiration phases. The method uses a viscous fluid model of tissue deformation to rnap voxels from one CT dataset to another. To validate the deformable matching algorithm we used a respiration-correlated CT protocol to acquire images at different phases of the respiratory cycle for six patients with nonsmall cell lung carcinoma. The position and shape of the deformable gross tumor volumes (GTV) at the end-inhale (EI) phase predicted by the algorithm was compared to those drawn by four observers. To minimize interobserver differences, all observers used the contours drawn by a single observer at end-exhale (EE) phase as a guideline to outline GTV contours at El. The differences between model-predicted and observer-drawn GTV surfaces at El, as well as differences between structures delineated by observers at El (interobserver variations) were evaluated using a contour comparison algorithm written for this purpose, which determined the distance between the two surfaces along different directions. The mean and 90% confidence interval for model-predicted versus observer-drawn GTV surface differences over all patients and all directions were 2.6 and 5.1 mm, respectively, whereas the mean and 90% confidence interval for interobserver differences were 2.1 and 3.7 mm. We have also evaluated the algorithm's ability to predict normal tissue deformations by examining the three-dimensional (3-D) vector displacement of 41 landmarks placed by each observer at bronchial and vascular branch points in the lung between the EE and EI image sets (mean and 90% confidence interval displacements of 11.7 and 25.1 mm, respectively). The mean and 90% confidence interval discrepancy between model-predicted and observer-determined landmark displacements over all patients were 2.9 and 7.3 rum, whereas interobserver discrepancies were 2.8 and 6.0 mm. Paired t tests indicate no significant statistical differences between model predicted and observer drawn structures. We conclude that the accuracy of the algorithm to map lung anatomy in CT images at different respiratory phases is comparable to the variability in manual delineation. This method has therefore the potential for predicting and quantifying respiration-induced tumor motion in the lung. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:369 / 376
页数:8
相关论文
共 28 条
[1]   Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing [J].
Balter, JM ;
TenHaken, RK ;
Lawrence, TS ;
Lam, KL ;
Robertson, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (01) :167-174
[2]  
BHARATHA A, 2004, MED PHY, V28, P2551
[3]   A deformable-model approach to semi-automatic segmentation of CT images demonstrated by application to the spinal canal [J].
Burnett, SSC ;
Starkschall, G ;
Stevens, CW ;
Liao, ZX .
MEDICAL PHYSICS, 2004, 31 (02) :251-263
[4]   Artifacts in computed tomography scanning of moving objects [J].
Chen, GTY ;
Kung, JH ;
Beaudette, KP .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :19-26
[5]   Volumetric transformation of brain anatomy [J].
Christensen, GE ;
Joshi, SC ;
Miller, MI .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (06) :864-877
[6]   Deformable templates using large deformation kinematics [J].
Christensen, GE ;
Rabbitt, RD ;
Miller, MI .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (10) :1435-1447
[7]   Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines [J].
Coselmon, MM ;
Balter, JM ;
McShan, DL ;
Kessler, ML .
MEDICAL PHYSICS, 2004, 31 (11) :2942-2948
[8]   Automatic registration of the prostate for computed-tomography-guided radiotherapy [J].
Court, LE ;
Dong, L .
MEDICAL PHYSICS, 2003, 30 (10) :2750-2757
[9]   Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning [J].
Ford, EC ;
Mageras, GS ;
Yorke, E ;
Ling, CC .
MEDICAL PHYSICS, 2003, 30 (01) :88-97
[10]   Large deformation three-dimensional image registration in image-guided radiation therapy [J].
Foskey, M ;
Davis, B ;
Goyal, L ;
Chang, S ;
Chaney, E ;
Strehl, N ;
Tomei, S ;
Rosenman, J ;
Joshi, S .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (24) :5869-5892