Multicenter pilot study of a serpentine balloon-expandable stent (beStent(TM)): Acute angiographic and clinical results

被引:9
作者
Beyar, R
Roguin, A
Hamburger, J
Saaiman, A
Bartorelli, AL
DiMario, C
Colombo, A
Hamm, CW
White, CJ
Marco, J
Serruys, PW
机构
[1] Rambam Medical Center, Haifa
[2] Thoraxcenter, Rotterdam
[3] Panorama Heart Unit, Capetown
[4] Institute of Cardiology, University of Milan
[5] Centro Cuore Columbus, Milan
[6] University Hospital, Hamburg
[7] HCI Medical Center, Clydebank
[8] Clinique Pasteur, Toulouse
[9] Division of Invasive Cardiology, Rambam Medical Center, Technion, Haifa
[10] Division of Invasive Cardiology, Rambam Medical Center, Bat Galim, Haifa 31096
关键词
D O I
10.1111/j.1540-8183.1997.tb00042.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The beStent is a new stainless steel, balloon-expandable mesh stent which has a unique serpentine design. Rotation of the unique low stress junctions upon expansion leads to orthogonal locking of the wires, maximizing radial strength and assuring zero shortening. The stent has delineating gold markers which assure precise positioning. We aim to present the initial acute results in a pilot registry for stent evaluation. Two hundred eighty-four stents were used in a total of 217 patients (age 57.9 +/- 3.10 years; 178 males; 39 females) in seven centers, for variable indications. Stents of 15-, 25-, and 35-mm length were used The arteries treated were the left anterior descending (n = 112, 42%), circumflex (n = 54, 20.2%), right coronary (n = 95, 35.5%), left main (n = 1, 0.4%), and vein graft (n = 5, 1.9%). Lesion types were: A in 42 patients (16.5%), B1 in 53 patients (20.7%); B2 in 81 patients (31.8%); and C in 79 patients (31%). One hundred fifty-nine patients required one stent, 40 patients required two stents, and 18 patients required three or more stents. Anticoagulation protocol included procedural heparin with aspirin with/without ticlopidine. Smooth angiographic results were obtained in all cases,vith no plaque herniation. Acute angiographic success was obtained in 97% of the patients, and acute clinical success in 95% of the patients. Complications within 30 days were: 3 deaths (1.4%) (2 noncardiac); 2 (0.9%) myocardial infarctions; and 2 (0.9%) stent thromboses. Therefore, the beStent is useful in treatment of complex lesions of variable length and complexity, providing excellent acute results with a low complication rate, in spite of unfavorable basic clinical and angiographic characteristics.
引用
收藏
页码:277 / 286
页数:10
相关论文
共 22 条
[1]  
BEYAR R, 1996, EUR HOSP MANAG J, V3, P64
[2]  
Beyar R., 1997, HDB CORONARY STENTS, P153
[3]   ANGIOGRAPHIC AND CLINICAL OUTCOME OF INTRACORONARY STENTING - IMMEDIATE AND LONG-TERM RESULTS FROM A LARGE SINGLE-CENTER EXPERIENCE [J].
CARROZZA, JP ;
KUNTZ, RE ;
LEVINE, MJ ;
POMERANTZ, RM ;
FISHMAN, RF ;
MANSOUR, M ;
GIBSON, CM ;
SENERCHIA, CC ;
DIVER, DJ ;
SAFIAN, RD ;
BAIM, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) :328-337
[4]  
DEJAEGERE P, 1993, CURR REV INTERV CARD, V8, P1
[5]   SMALL STENT SIZE AND INTIMAL HYPERPLASIA CONTRIBUTE TO RESTENOSIS - A VOLUMETRIC INTRAVASCULAR ULTRASOUND ANALYSIS [J].
DUSSAILLANT, GR ;
MINTZ, GS ;
PICHARD, AD ;
KENT, KM ;
SATLER, LF ;
POPMA, JJ ;
WONG, SC ;
LEON, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (03) :720-724
[6]   RESTENOSIS AFTER PLACEMENT OF PALMAZ-SCHATZ STENTS IN NATIVE CORONARY-ARTERIES - INITIAL RESULTS OF A MULTICENTER EXPERIENCE [J].
ELLIS, SG ;
SAVAGE, M ;
FISCHMAN, D ;
BAIM, DS ;
LEON, M ;
GOLDBERG, S ;
HIRSHFELD, JW ;
CLEMAN, MW ;
TEIRSTEIN, PS ;
WALKER, C ;
BAILEY, S ;
BUCHBINDER, M ;
TOPOL, EJ ;
SCHATZ, RA .
CIRCULATION, 1992, 86 (06) :1836-1844
[7]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[8]   MULTICENTER INVESTIGATION OF CORONARY STENTING TO TREAT ACUTE OR THREATENED CLOSURE AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - CLINICAL AND ANGIOGRAPHIC OUTCOMES [J].
GEORGE, BS ;
VOORHEES, WD ;
ROUBIN, GS ;
FEARNOT, NE ;
PINKERTON, CA ;
RAIZNER, AE ;
KING, SB ;
HOLMES, DR ;
TOPOL, EJ ;
KEREIAKES, DJ ;
HARTZLER, GO .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (01) :135-143
[9]   EMERGENT USE OF BALLOON-EXPANDABLE CORONARY-ARTERY STENTING FOR FAILED PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
HERRMANN, HC ;
BUCHBINDER, M ;
CLEMEN, MW ;
FISCHMAN, D ;
GOLDBERG, S ;
LEON, MB ;
SCHATZ, RA ;
TIERSTEIN, P ;
WALKER, CM ;
HIRSHFELD, JW .
CIRCULATION, 1992, 86 (03) :812-819
[10]   SERIAL ANGIOGRAPHIC FOLLOW-UP AFTER PALMAZ-SCHATZ STENT IMPLANTATION - COMPARISON WITH CONVENTIONAL BALLOON ANGIOPLASTY [J].
KIMURA, T ;
NOSAKA, H ;
YOKOI, H ;
IWABUCHI, M ;
NOBUYOSHI, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (07) :1557-1563