摘要
Ion beams exhibit a finite range and an inverted depth-dose profile, the Bragg peak. These favorable physical properties allow excellent tumor-dose conformality. However, they introduce sensitivity to range uncertainties. Although these uncertainties are typically taken into account in treatment planning, delivery of the intended dose to the patient has to be ensured daily to prevent underdosage of the tumor or overdosage of surrounding critical structures. Thus, imaging techniques play an increasingly important role for treatment planning and in situ monitoring in ion beam therapy. At the Heidelberg Ion Beam Therapy (HIT) center, a prototype detector system based on a stack of 61 ionization chambers has been assembled for the purpose of radiographic and tomographic imaging of transmitted energetic ions. Its applicability to ion-based transmission imaging was investigated experimentally. An extensive characterization of the set-up in terms of beam parameters and settings of the read-out electronics was performed. Overall, the findings of this work support the potential of an efficient experimental set-up as the range telescope equipped with high sensitivity and fast electronics to perform heavy ion radiography and tomography at HIT.
引用
收藏
页码:413 / 427
页数:15
相关论文
共 50 条
  • [1] Quantitative carbon ion beam radiography and tomography with a flat-panel detector
    Telsemeyer, Julia
    Jaeakel, Oliver
    Martisikova, Maria
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (23) : 7957 - 7971
  • [2] Heavy ion radiography and tomography
    Parodi, K.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (05): : 539 - 543
  • [3] Investigations on novel imaging techniques for ion beam therapy: carbon ion radiography and tomography
    Rinaldi, I.
    Brons, S.
    Jaekel, O.
    Mairani, A.
    Panse, R.
    Voss, B.
    Parodi, K.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2805 - 2810
  • [4] Experimental investigations on carbon ion scanning radiography using a range telescope
    Rinaldi, I.
    Brons, S.
    Jaekel, O.
    Voss, B.
    Parodi, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (12) : 3041 - 3057
  • [5] Characterization of a MLIC Detector for QA in Scanned Proton and Carbon Ion Beams
    Vai, Alessandro
    Mirandola, Alfredo
    Magro, Giuseppe
    Maestri, Davide
    Mastella, Edoardo
    Mairani, Andrea
    Molinelli, Silvia
    Russo, Stefania
    Togno, Michele
    La Civita, Sara
    Ciocca, Mario
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2019, 6 (02): : 50 - 59
  • [6] Dosimetric characterization of a microDiamond detector in clinical scanned carbon ion beams
    Marinelli, Marco
    Prestopino, G.
    Verona, C.
    Verona-Rinati, G.
    Ciocca, M.
    Mirandola, A.
    Mairani, A.
    Raffaele, L.
    Magro, G.
    MEDICAL PHYSICS, 2015, 42 (04) : 2085 - 2093
  • [7] A novel proton-integrating radiography system design using a monolithic scintillator detector: Experimental studies
    Darne, Chinmay D.
    Robertson, Daniel G.
    Alsanea, Fahed
    Collins-Fekete, Charles-Antoine
    Beddar, Sam
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1027
  • [8] Comparison of computed radiography and multi-detector computed tomography in the detection of postmortem metacarpal index
    Reid, Aoife
    Schneider-Kolsky, Michal Elisabeth
    O'Donnell, Christopher James
    FORENSIC SCIENCE INTERNATIONAL, 2008, 177 (2-3) : 192 - 198
  • [9] A detector system for a high-energy phase-contrast human computed tomography experimental device
    Sun, Rongqi
    Chen, Lian
    Wei, Wenbin
    Jin, Ge
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 946
  • [10] Characterization of a commercial scintillation detector for 2-D dosimetry in scanned proton and carbon ion beams
    Russo, S.
    Mirandola, A.
    Molinelli, S.
    Mastella, E.
    Vai, A.
    Magro, G.
    Mairani, A.
    Boi, D.
    Donetti, M.
    Ciocca, M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 34 : 48 - 54