An underwater blood pressure measuring device

被引:1
作者
Sieber, Arne [1 ]
Kuch, Benjamin [2 ]
L'Abbate, Antonio
Wagner, Matthias [2 ]
Dario, Paolo
Bedini, Remo [1 ]
机构
[1] CNR, Inst Clin Physiol, I-56100 Pisa, Italy
[2] Univ Appl Sci, Frankfurt, Germany
关键词
Blood pressure; equipment; immersion; diving; cardiovascular; physiology;
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Measurement of arterial blood pressure is an important vital sign for monitoring the circulation. However, up to now no instrument has been available that enables the measurement of blood pressure underwater. The present paper details a novel, oscillometric, automatic digital blood pressure (BP) measurement device especially designed for this purpose. It consists mainly of analogue and digital electronics in a lexan housing that is rated to a depth of up to 200 metres' sea water, a cuff and a solenoid for inflation of the cuff with air supplied from a scuba tank. An integrated differential pressure sensor, exposed to the same ambient pressure as the cuff, allows accurate BP measurement. Calculation of systolic and diastolic pressures is based on the analysis of pressure oscillations recorded during the deflation. In hyperbaric chamber tests to pressures up to 405 kPa, BP measurements taken with the prototype were comparable to those obtained with established manual and automated methods. Swimming pool tests confirmed the correct functioning of the system underwater. The quality of the recorded pressure oscillations was very good even at 10 metres' fresh water, and allowed determination of diastolic and systolic pressures values. Based on these results we envisage that this device will lead to a better understanding of human cardiovascular physiology in underwater and hyperbaric environments.
引用
收藏
页码:128 / 134
页数:7
相关论文
共 50 条
[21]   Measuring of Systolic Blood Pressure Based On Heart Rate [J].
Hassan, M. K. Ali ;
Mashor, M. Y. ;
Nasir, N. F. Mohd ;
Mohamed, S. .
4TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2008, VOLS 1 AND 2, 2008, 21 (1-2) :595-+
[22]   A SYSTEM FOR NONINVASIVELY MEASURING BLOOD-PRESSURE ON A TREADMILL [J].
AU, TCP ;
WEBSTER, JG ;
TAN, BT .
PHYSIOLOGICAL MEASUREMENT, 1995, 16 (04) :273-285
[23]   The Application of Wavelet Neural Network in Measuring Blood Pressure [J].
Huo, Chunbao ;
Zhao, Lihui ;
Ma, Yonghong .
2008 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-11, 2008, :120-123
[24]   Validation of a Remote Monitoring Blood Pressure Device in Pregnancy [J].
Oben, Ayamo ;
Moore, Matthew ;
Wallace, Eric ;
Muntner, Paul ;
Oparil, Suzanne ;
Tita, Alan ;
Sinkey, Rachel .
AMERICAN JOURNAL OF HYPERTENSION, 2023, 36 (06) :341-347
[25]   The Development of an Interactive Blood Pressure Device for Telemedicine Application [J].
Mustapha, B. ;
Jeganathan, P. ;
Yahya, R. ;
Adlan, F. .
2015 Innovation & Commercialization of Medical Electronic Technology Conference (ICMET), 2015, :61-67
[26]   DEVELOPMENT OF A PULSE OXIMETER AND BLOOD PRESSURE MEASUREMENT DEVICE [J].
Fe, Ana ;
Sousa, Joana ;
Gamboa, Hugo .
BIODEVICES: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2012, :201-206
[27]   Underwater study of arterial blood pressure in breath-hold divers [J].
Sieber, Arne ;
L'Abbate, Antonio ;
Passera, Mirko ;
Garbella, Erika ;
Benassi, Antonio ;
Bedini, Remo .
JOURNAL OF APPLIED PHYSIOLOGY, 2009, 107 (05) :1526-1531
[28]   A new non-invasive device for measuring instantaneous blood pressure in radial artery based on the volume-compensation method [J].
Tanaka, S ;
Gao, S ;
Nogawa, M ;
Yamakoshi, K .
PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 :3149-3152
[29]   Feasibility and Effectiveness of a Ring-Type Blood Pressure Measurement Device Compared With 24-Hour Ambulatory Blood Pressure Monitoring Device [J].
Lee, Huijin ;
Park, Sungjoon ;
Kwon, Hyuktae ;
Cho, Belong ;
Park, Jin Ho ;
Lee, Hae-Young .
KOREAN CIRCULATION JOURNAL, 2024, 54 (02) :93-104
[30]   Prototype for measuring blood pressure on the Android platform for mobile devices [J].
Flavio, Pineda-Lopez ;
Darwin, Alulema ;
Mauricio, Vinueza ;
Edwin, Garcia ;
Derlin, Morocho .
2015 CHILEAN Conference on Electrical, Electronics Engineering, Information and Communication Technologies (CHILECON), 2015, :199-204