Simulation of a central scotoma using contact lenses with an opaque centre

被引:9
作者
Almutleb, Essam S. [1 ,2 ]
Bradley, Arthur [1 ]
Jedlicka, Jason [1 ]
Hassan, Shirin E. [1 ]
机构
[1] Indiana Univ, Sch Optometry, Bloomington, IN 47405 USA
[2] King Saud Univ, Optometry & Vis Sci Dept, Coll Appl Med Sci, Riyadh, Saudi Arabia
关键词
age-related macular degeneration (AMD); contact lenses; experimental AMD model; low vision; simulated central scotoma; PREFERRED RETINAL LOCI; AUTOMATED KINETIC PERIMETRY; CENTRAL VISION LOSS; CENTRAL FIELD LOSS; MACULAR DEGENERATION; READING SPEED; FIXATION STABILITY; VISUAL-ACUITY; REACTION-TIME; DISEASE;
D O I
10.1111/opo.12422
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeThis study evaluated the feasibility of using soft contact lenses (CLs) with an opaque centre to induce absolute central scotomas that move with the eye. We examined the geometrical optics prediction that scotoma size will vary with the size of the CL's opaque centre and with ocular pupil size. We also tested the hypothesis that high environmental light levels will ensure that the ocular pupil will remain small enough, even with opaque centre CLs, to generate absolute scotomas representative of those experienced by patients with age-related macular disease. MethodsUsing an Octopus 900 Perimeter ( ), kinetic visual fields (VFs) were measured in five normally-sighted subjects using a V4e Goldmann target with CLs that had central opaque areas with diameters of 2.8, 3.0, and 3.2mm. To control pupil size, VFs were measured with background perimeter bowl luminances of 10, 585, and 1155cdm(-2). Subjects attempted to (i) fixate the bowl centre; and (ii) place the scotoma edge at the bowl fixation target (eccentric viewing). ResultsAs predicted, there was a direct relationship between scotoma size and both luminance level and diameter of the opacity. Mean scotoma diameters were 0 degrees, 17.6 degrees and 22 degrees, for the low, medium and high bowl luminances, respectively. Scotoma size was determined primarily by the difference between the diameters of CL opacity and the entrance pupil of the eye and the axial separation between them, and between-subject differences in pupil diameters contributed most to the between-subject variability in scotoma diameter at each light level (SD: 6.01 degrees). Scotoma displacement during eccentric fixation confirmed the gaze-contingent characteristics of this experimental model. ConclusionIt is possible to induce a gaze-contingent absolute scotoma and hence mimic central vision loss using centrally-opaque CLs provided that the CL opacity is larger than the entrance pupil of the eye. This simulation tool will, therefore, be ineffective at low environmental light levels (as shown previously) if the entrance pupil of the eye is larger than the CL opacity.
引用
收藏
页码:76 / 87
页数:12
相关论文
共 59 条
[1]   Seeing for yourself:: Feasibility study towards valuing visual impairment using simulation spectacles [J].
Aballea, Samuel ;
Tsuchiya, Aki .
HEALTH ECONOMICS, 2007, 16 (05) :537-543
[2]  
Akpek EK, 2013, AM J MANAG CARE, V19, pS67
[3]   Do small-aperture presbyopic corrections influence the visual field? [J].
Atchison, David A. ;
Blazaki, Stella ;
Suheimat, Marwan ;
Plainis, Sotiris ;
Charman, W. Neil .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2016, 36 (01) :51-59
[4]   Anxiety and depression prevalence rates in age-related macular degeneration [J].
Augustin, Albert ;
Sahel, Jose-Alain ;
Bandello, Francesco ;
Dardennes, Roland ;
Maurel, Frederique ;
Negrini, Cristina ;
Hieke, Klaus ;
Berdeaux, Gilles .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (04) :1498-1503
[5]  
Aulhorn E, 1972, VISUAL PERIMETRY
[6]   Driving avoidance and functional impairment in older drivers [J].
Ball, K ;
Owsley, C ;
Stalvey, B ;
Roenker, DL ;
Sloane, ME ;
Graves, M .
ACCIDENT ANALYSIS AND PREVENTION, 1998, 30 (03) :313-322
[7]   Factors influencing reaction time during automated kinetic Perimetry on the Tubingen computer campimeter [J].
Becker, ST ;
Vonthein, R ;
Volpe, NJ ;
Schiefer, U .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) :2633-2638
[8]   Objective analysis of contact lens fit [J].
Belda-Salmeron, Lurdes ;
Drew, Tom ;
Hall, Lee ;
Wolffsohn, James Stuart .
CONTACT LENS & ANTERIOR EYE, 2015, 38 (03) :163-167
[9]   Fixation stability using central and pericentral fixation targets in patients with age-related macular degeneration [J].
Bellmann, C ;
Feely, M ;
Crossland, MD ;
Kabanarou, SA ;
Rubin, GS .
OPHTHALMOLOGY, 2004, 111 (12) :2265-2270
[10]   Page mode reading with simulated scotomas: A modest effect of interline spacing on reading speed [J].
Bernard, Jean-Baptiste ;
Anne-Catherine, Scherlen ;
Eric, Castet .
VISION RESEARCH, 2007, 47 (28) :3447-3459