A Methodology for Optimal Design of Transmission Lines Protection against Lightning Surges in the Presence of Arresters

被引:0
|
作者
Shariatinasab, Reza [1 ]
Azimi, Reza [1 ]
机构
[1] Univ Birjand, Dept Elect & Comp Engn, Birjand, Iran
关键词
PROBABILISTIC EVALUATION; OPTIMAL LOCATION; BEHAVIOR;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a methodology for determining the optimal value of protection design parameters of transmission lines (TLs) is presented. The proposed method calculates the shielding failure flashover rate (SFFOR) and back flashover rate (BFR) of transmission lines based on the Electrogeometric model of TLs and the Monte Carlo simulation method, respectively. The accuracy of the proposed method is verified by comparing the associated results with those obtained with the IEEE FLASH program. The proposed method can be used to achieve the minimum lightning flashover rate (LFOR) of TLs by the minimum investment cost Indirectly, it can be used for determining the appropriate value of the footing resistance, insulation strength, and arrester rating to satisfy a specified number of LFOR that might be given by the power utilities.
引用
收藏
页码:105 / 110
页数:6
相关论文
共 50 条
  • [1] A methodology for optimal design of transmission lines protection against lightning surges in the presence of arresters
    Shariatinasab R.
    Azimi R.
    Advanced Electromagnetics, 2020, 9 (01): : 105 - 110
  • [2] Design and application of line surge arresters to improve lightning protection characteristics of transmission lines
    He, Jin-Liang
    Zeng, Rong
    Hu, Jun
    Chen, Shui-Ming
    Zhao, Jie
    2008 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2008, : 1562 - +
  • [3] Lightning protection of transmission lines: optimal shielding design procedure
    Nguyen, TT
    Holt, R
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2003, 150 (06) : 659 - 667
  • [4] Optimal placement of surge arresters for transmission lines lightning performance improvement
    Castro, Walace S.
    Lopes, Ivan J. S.
    Misse, Silvio L., V
    Vasconcelos, Joao A.
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 202
  • [5] Investigation of effect of transmission line arresters verified by lightning surges at substations
    Ueda, T
    ELECTRICAL ENGINEERING IN JAPAN, 1999, 126 (04) : 30 - 39
  • [6] Investigation of effect of transmission line arresters verified by lightning surges at substations
    Ueda, Toshiaki
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 1999, 126 (04): : 30 - 39
  • [7] Simulation of Line Surge Arresters for Lightning Protection in 10kV Transmission Lines
    Wang Yong
    Xie Pu
    Zhao Jin-cheng
    Zhang Gui-fang
    2008 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION, VOLS 1 AND 2, 2009, : 269 - +
  • [8] Dimensioning of SPD for the protection against surges due to lightning to LV overhead lines
    Kisielewicz, T.
    Lo Piparo, G. B.
    Mazzetti, C.
    Rousseau, A.
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 141 - 145
  • [9] Protection provided by ground wire against induced lightning surges on distribution lines
    Thapar, B
    Gerez, V
    PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 61 - I AND II, 1999, 61 : 435 - 439
  • [10] Measurement of lightning surges on test transmission line equipped with arresters struck by natural and triggered lightning
    Matsumoto, Y
    Sakuma, O
    Shinjo, K
    Saiki, M
    Wakai, T
    Sakai, T
    Nagasaka, H
    Motoyama, H
    Ishii, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (02) : 996 - 1002