Optimization of mechanical properties, biocorrosion properties and antibacterial properties of as-cast Ti-Cu alloys

被引:81
作者
Zhang, Erlin [1 ]
Ren, Jing [1 ]
Li, Shengyi [1 ]
Yang, Lei [1 ]
Qin, Gaowu [1 ]
机构
[1] Northeastern Univ, Sch Mat Sci & Engn, Educ Minist China, Key Lab Anisotropy & Texture Mat, Shenyang 110819, Peoples R China
关键词
Ti-Cu alloy; heat treatment; microstructure; mechanical properties; corrosion resistance; antibacterial properties; STRESS-CORROSION CRACKING; STAINLESS-STEEL; TI-6AL-4V-XCU ALLOYS; IMPLANT APPLICATION; HEAT-TREATMENT; BODY-FLUID; TITANIUM; BEHAVIOR; SURFACE; PERFORMANCE;
D O I
10.1088/1748-6041/11/6/065001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ti-Cu sintered alloys have shown good antibacterial abilities. However, the sintered method (powder metallurgy) is not convenient to produce devices with a complex structure. In this paper, Ti-Cu alloys with 2.0, 3.0 and 4.0 wt.% Cu were prepared in an arc melting furnace and subjected to different heat treatments: solid solution and ageing, to explore the possibility of preparing an antibacterial Ti-Cu alloy by a casting method and to examine the effect of Cu content. Phase identification was conducted on an XRD diffraction meter, and the microstructure was observed by a metallographic microscope, a scanning electron microscope (SEM) with energy disperse spectroscopy (EDS) and transmission electron microscopy (TEM). Microhardness and the compressive property of Ti-Cu alloys were tested, and the corrosion resistance and antibacterial activity were assessed in order to investigate the effect of the Cu content. Results showed that the as-cast Ti-Cu alloys exhibited a very low antibacterial rate against Staphylococcus aureus (S. aureus). Heat treatment improved the antibacterial rate significantly, especially after a solid and ageing treatment (T6). Antibacterial rates as high as 90.33% and 92.57% were observed on Ti-3Cu alloy and Ti-4Cu alloy, respectively. The hardness, the compressive yield strength, the anticorrosion resistance and the antibacterial rate of Ti-Cu alloys increased with an increase of Cu content in all conditions. It was demonstrated that homogeneous distribution and a fine Ti2Cu phase played a very important role in the mechanical property, anticorrosion and antibacterial properties. Furthermore, it should be pointed out that the Cu content should be at least 3 wt.% to obtain good antibacterial properties (> 90% antibacterial rate) as well as satisfactory mechanical properties.
引用
收藏
页数:13
相关论文
共 53 条
  • [1] [Anonymous], GB478922010 MIN HLTH
  • [2] [Anonymous], 2003, ANTIMICROBIAL PLASTI
  • [3] Bacterial biofilms may contribute to persistent cochlear implant infection
    Antonelli, PJ
    Lee, JC
    Burne, TA
    [J]. OTOLOGY & NEUROTOLOGY, 2004, 25 (06) : 953 - 957
  • [4] Mechanical properties of cast Ti-6Al-4V-XCu alloys
    Aoki, T
    Okafor, ICI
    Watanabe, I
    Hattori, M
    Oda, Y
    Okabe, T
    [J]. JOURNAL OF ORAL REHABILITATION, 2004, 31 (11) : 1109 - 1114
  • [5] Baker H, 1992, INTRO ALLOY PHASE DI, V1, P1
  • [6] Cao C, 2004, PRINCIPLE CORROSION, P3276
  • [7] Chen Y, 2006, INT TECHN INN C, P435
  • [8] Fehring TK, 2001, CLIN ORTHOP RELAT R, P315
  • [9] Ti alloy design strategy for biomedical applications
    He, G
    Hagiwara, M
    [J]. MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2006, 26 (01): : 14 - 19
  • [10] Backgrounds of antibiotic-loaded bone cement and prosthesis-related infection
    Hendriks, JGE
    van Horn, JR
    van der Mei, HC
    Busscher, HJ
    [J]. BIOMATERIALS, 2004, 25 (03) : 545 - 556