Selective determination of urea using urease immobilized on ZnO nanowires

被引:79
作者
Ali, Syed M. Usman [1 ]
Ibupoto, Zafar Hussain [1 ]
Salman, Salah [2 ]
Nur, Omer [1 ]
Willander, Magnus [1 ]
Danielsson, Bengt [2 ]
机构
[1] Linkoping Univ, Dept Sci & Technol, Phys Elect & Nanotechnol Div, SE-60174 Norrkoping, Sweden
[2] Acromed Invest AB, SE-22643 Lund, Sweden
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2011年 / 160卷 / 01期
关键词
ZnO-nanowire arrays; Electrochemical nanodevices; Urease enzyme; Urea determination; BIOSENSOR; BLOOD; MATRIX; SENSOR;
D O I
10.1016/j.snb.2011.08.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Well-aligned zinc oxide (ZnO) nanowire arrays were fabricated on gold-coated plastic substrates using a low-temperature aqueous chemical growth (ACG) method. The ZnO nanowire arrays with 50-130 nm diameters and similar to 1 mu m in lengths were used in an enzyme-based urea sensor through immobilization of the enzyme urease that was found to be sensitive to urea concentrations from 0.1 mM to 100 mM. Two linear sensitivity regions were observed when the electrochemical responses (EMF) of the sensors were plotted vs. the logarithmic concentration range of urea from 0.1 mM to 100 mM. The proposed sensor showed a sensitivity of 52.8 mV/decade for 0.1-40 mM urea and a fast response time less than 4s was achieved with good selectivity, reproducibility and negligible response to common interferents such as ascorbic acid and uric acid, glucose. K+ and Na+ ions. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:637 / 643
页数:7
相关论文
共 28 条
  • [1] Nanostructured zinc oxide film for urea sensor
    Ali, Azahar
    Ansari, Anees A.
    Kaushik, Ajeet
    Solanki, Pratima R.
    Barik, A.
    Pandey, M. K.
    Malhotra, B. D.
    [J]. MATERIALS LETTERS, 2009, 63 (28) : 2473 - 2475
  • [2] Selective potentiometric determination of uric acid with uricase immobilized on ZnO nanowires
    Ali, Syed M. Usman
    Alvi, N. H.
    Ibupoto, Zafar
    Nur, Omer
    Willander, Magnus
    Danielsson, Bengt
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2011, 152 (02) : 241 - 247
  • [3] A fast and sensitive potentiometric glucose microsensor based on glucose oxidase coated ZnO nanowires grown on a thin silver wire
    Ali, Syed M. Usman
    Nur, O.
    Willander, M.
    Danielsson, B.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (02) : 869 - 874
  • [4] Intracellular K+ Determination With a Potentiometric Microelectrode Based on ZnO Nanowires
    Ali, Syed Muhammad Usman
    Asif, Muhammad H.
    Fulati, Alimujiang
    Nur, Omer
    Willander, Magnus
    Brannmark, Cecilia
    Stralfors, Peter
    Englund, Ulrika H.
    Elinder, Fredrik
    Danielsson, Bengt
    [J]. IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2011, 10 (04) : 913 - 919
  • [5] Glucose Detection With a Commercial MOSFET Using a ZnO Nanowires Extended Gate
    Ali, Syed Muhammad Usman
    Nur, Omer
    Willander, Magnus
    Danielsson, Bengt
    [J]. IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2009, 8 (06) : 678 - 683
  • [6] Fabrication and comparative optical characterization of n-ZnO nanostructures (nanowalls, nanorods, nanoflowers and nanotubes)/p-GaN white-light-emitting diodes
    Alvi, N. H.
    Ali, S. M. Usman
    Hussain, S.
    Nur, O.
    Willander, M.
    [J]. SCRIPTA MATERIALIA, 2011, 64 (08) : 697 - 700
  • [7] Immobilization of urease on vermiculite
    Anita, A
    Sastry, CA
    Hashim, MA
    [J]. BIOPROCESS ENGINEERING, 1997, 16 (06) : 375 - 380
  • [8] [Anonymous], 2006, Encyclopedia of sensors, potentiometric ion sensors
  • [9] Sol-gel derived nanostructured cerium oxide film for glucose sensor
    Ansari, Anees A.
    Solanki, Pratima R.
    Malhotra, B. D.
    [J]. APPLIED PHYSICS LETTERS, 2008, 92 (26)
  • [10] Urea sensor based on tin oxide thin films prepared by modified plasma enhanced CVD
    Ansari, S. G.
    Ansari, Z. A.
    Seo, Hyung-Kee
    Kim, Gil-Sung
    Kim, Young-Soon
    Khang, Gilson
    Shin, Hyung-Shik
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2008, 132 (01): : 265 - 271