3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models

被引:17
|
作者
Dhou, S. [1 ,2 ]
Hurwitz, M. [1 ,2 ]
Mishra, P. [3 ]
Cai, W. [1 ,2 ]
Rottmann, J. [1 ,2 ]
Li, R. [4 ]
Williams, C. [1 ,2 ]
Wagar, M. [1 ,2 ]
Berbeco, R. [1 ,2 ]
Ionascu, D. [5 ]
Lewis, J. H. [1 ,2 ]
机构
[1] Brigham & Womens Hosp, Dana Farber Canc Inst, Dept Radiat Oncol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Varian Med Syst, Palo Alto, CA USA
[4] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[5] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI USA
关键词
cone-beam CT; motion model; 3D fluoroscopic images; CONE-BEAM CT; TOTAL-VARIATION MINIMIZATION; LUNG-CANCER RADIOTHERAPY; COMPUTED-TOMOGRAPHY; RESPIRATORY MOTION; TUMOR-LOCALIZATION; XCAT PHANTOM; RECONSTRUCTION; REGISTRATION; PROJECTIONS;
D O I
10.1088/0031-9155/60/9/3807
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
3D fluoroscopic images represent volumetric patient anatomy during treatment with high spatial and temporal resolution. 3D fluoroscopic images estimated using motion models built using 4DCT images, taken days or weeks prior to treatment, do not reliably represent patient anatomy during treatment. In this study we developed and performed initial evaluation of techniques to develop patient-specific motion models from 4D cone-beam CT (4DCBCT) images, taken immediately before treatment, and used these models to estimate 3D fluoroscopic images based on 2D kV projections captured during treatment. We evaluate the accuracy of 3D fluoroscopic images by comparison to ground truth digital and physical phantom images. The performance of 4DCBCT-based and 4DCT-based motion models are compared in simulated clinical situations representing tumor baseline shift or initial patient positioning errors. The results of this study demonstrate the ability for 4DCBCT imaging to generate motion models that can account for changes that cannot be accounted for with 4DCT-based motion models. When simulating tumor baseline shift and patient positioning errors of up to 5 mm, the average tumor localization error and the 95th percentile error in six datasets were 1.20 and 2.2 mm, respectively, for 4DCBCT-based motion models. 4DCT-based motion models applied to the same six datasets resulted in average tumor localization error and the 95th percentile error of 4.18 and 5.4 mm, respectively. Analysis of voxel-wise intensity differences was also conducted for all experiments. In summary, this study demonstrates the feasibility of 4DCBCT-based 3D fluoroscopic image generation in digital and physical phantoms and shows the potential advantage of 4DCBCT-based 3D fluoroscopic image estimation when there are changes in anatomy between the time of 4DCT imaging and the time of treatment delivery.
引用
收藏
页码:3807 / 3824
页数:18
相关论文
共 50 条
  • [31] 3D Printer Application for Endoscope-Assisted Spine Surgery Instrument Development: From Prototype Instruments to Patient-Specific 3D Models
    Yang, Hee-Seok
    Park, Jeong-Yoon
    YONSEI MEDICAL JOURNAL, 2020, 61 (01) : 94 - 99
  • [32] Recent advance in patient-specific 3D printing templates in mandibular reconstruction
    Lu T.
    Shao Z.
    Liu B.
    Wu T.
    Journal of the Mechanical Behavior of Biomedical Materials, 2020, 106
  • [33] Recent advance in patient-specific 3D printing templates in mandibular reconstruction
    Lu, Tingwei
    Shao, Zhe
    Liu, Bing
    Wu, Tianfu
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 106
  • [34] Patient-specific in silico 3D coronary model in cardiac catheterisation laboratories
    Lashgari, Mojtaba
    Choudhury, Robin P.
    Banerjee, Abhirup
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [35] Patient-specific model-based segmentation of brain tumors in 3D intraoperative ultrasound images
    Ilunga-Mbuyamba, Elisee
    Gabriel Avina-Cervantes, Juan
    Lindner, Dirk
    Arlt, Felix
    Fulbert Ituna-Yudonago, Jean
    Chalopin, Claire
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (03) : 331 - 342
  • [36] Basal osteotomy of the first metacarpal using patient-specific guides and instrumentation: biomechanical and 3D CT-based analysis
    Nuesch, Clea
    Schweizer, Andreas
    Weber, Andreas
    Reissner, Lisa
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (01) : 551 - 558
  • [37] Automatic scale estimation of structure from motion based 3D models using laser scalers in underwater scenarios
    Istenic, Klemen
    Gracias, Nuno
    Arnaubec, Aurelien
    Escartin, Javier
    Garcia, Rafael
    ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2020, 159 : 13 - 25
  • [38] Computing patient-specific hemodynamics in stented femoral artery models obtained from computed tomography using a validated 3D reconstruction method
    Colombo, Monika
    Bologna, Marco
    Garbey, Marc
    Berceli, Scott
    He, Yong
    Matas, Jose Felix Rodriguez
    Migliavacca, Francesco
    Chiastra, Claudio
    MEDICAL ENGINEERING & PHYSICS, 2020, 75 : 23 - 35
  • [39] HIGHLY ACCURATE AUTOMATED PATIENT-SPECIFIC 3D BONE POSE AND SCALE ESTIMATION USING BI-PLANAR POSE-INVARIANT PATCHES IN A CNN-BASED 3D/2D REGISTRATION FRAMEWORK
    Khameneh, Nahid Babazadeh
    Vazquez, Carlos
    Cresson, Thierry
    Lavoie, Frederic
    de Guise, Jacques
    2021 IEEE 18TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2021, : 681 - 684
  • [40] 3D motion estimation of hand based on feature points
    Huang, Wen-Qing
    Chen, Hong-Wei
    Zhang, Yun-Hua
    PROCEEDINGS OF 2006 INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND CYBERNETICS, VOLS 1-7, 2006, : 3919 - +