3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models

被引:17
|
作者
Dhou, S. [1 ,2 ]
Hurwitz, M. [1 ,2 ]
Mishra, P. [3 ]
Cai, W. [1 ,2 ]
Rottmann, J. [1 ,2 ]
Li, R. [4 ]
Williams, C. [1 ,2 ]
Wagar, M. [1 ,2 ]
Berbeco, R. [1 ,2 ]
Ionascu, D. [5 ]
Lewis, J. H. [1 ,2 ]
机构
[1] Brigham & Womens Hosp, Dana Farber Canc Inst, Dept Radiat Oncol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Varian Med Syst, Palo Alto, CA USA
[4] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[5] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI USA
关键词
cone-beam CT; motion model; 3D fluoroscopic images; CONE-BEAM CT; TOTAL-VARIATION MINIMIZATION; LUNG-CANCER RADIOTHERAPY; COMPUTED-TOMOGRAPHY; RESPIRATORY MOTION; TUMOR-LOCALIZATION; XCAT PHANTOM; RECONSTRUCTION; REGISTRATION; PROJECTIONS;
D O I
10.1088/0031-9155/60/9/3807
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
3D fluoroscopic images represent volumetric patient anatomy during treatment with high spatial and temporal resolution. 3D fluoroscopic images estimated using motion models built using 4DCT images, taken days or weeks prior to treatment, do not reliably represent patient anatomy during treatment. In this study we developed and performed initial evaluation of techniques to develop patient-specific motion models from 4D cone-beam CT (4DCBCT) images, taken immediately before treatment, and used these models to estimate 3D fluoroscopic images based on 2D kV projections captured during treatment. We evaluate the accuracy of 3D fluoroscopic images by comparison to ground truth digital and physical phantom images. The performance of 4DCBCT-based and 4DCT-based motion models are compared in simulated clinical situations representing tumor baseline shift or initial patient positioning errors. The results of this study demonstrate the ability for 4DCBCT imaging to generate motion models that can account for changes that cannot be accounted for with 4DCT-based motion models. When simulating tumor baseline shift and patient positioning errors of up to 5 mm, the average tumor localization error and the 95th percentile error in six datasets were 1.20 and 2.2 mm, respectively, for 4DCBCT-based motion models. 4DCT-based motion models applied to the same six datasets resulted in average tumor localization error and the 95th percentile error of 4.18 and 5.4 mm, respectively. Analysis of voxel-wise intensity differences was also conducted for all experiments. In summary, this study demonstrates the feasibility of 4DCBCT-based 3D fluoroscopic image generation in digital and physical phantoms and shows the potential advantage of 4DCBCT-based 3D fluoroscopic image estimation when there are changes in anatomy between the time of 4DCT imaging and the time of treatment delivery.
引用
收藏
页码:3807 / 3824
页数:18
相关论文
共 50 条
  • [21] Treatment of Facial Deformities using 3D Planning and Printing of Patient-Specific Implants
    Shilo, Dekel
    Capucha, Tal
    Goldstein, Dana
    Bereznyak, Yekaterina
    Emodi, Omri
    Rachmiel, Adi
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (159):
  • [22] Generation of fluoroscopic 3D images with a respiratory motion model based on an external surrogate signal
    Hurwitz, Martina
    Williams, Christopher L.
    Mishra, Pankaj
    Rottmann, Joerg
    Dhou, Salam
    Wagar, Matthew
    Mannarino, Edward G.
    Mak, Raymond H.
    Lewis, John H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02) : 521 - 535
  • [23] Patient-Specific Biomechanical Model for the Prediction of Lung Motion From 4-D CT Images
    Fuerst, Bernhard
    Mansi, Tommaso
    Carnis, Francois
    Saelzle, Martin
    Zhang, Jingdan
    Declerck, Jerome
    Boettger, Thomas
    Bayouth, John
    Navab, Nassir
    Kamen, Ali
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) : 599 - 607
  • [24] Patient specific respiratory motion modeling using a 3D patient's external surface
    Fayad, Hadi
    Pan, Tinsu
    Pradier, Olivier
    Visvikis, Dimitris
    MEDICAL PHYSICS, 2012, 39 (06) : 3386 - 3395
  • [25] 3D Active Shape Models Of Human Brain Structures: Application To Patient-Specific Mesh Generation
    Ravikumar, Nishant
    Castro-Mateos, Isaac
    Pozo, Jose M.
    Frangi, Alejandro F.
    Taylor, Zeike A.
    MEDICAL IMAGING 2015: COMPUTER-AIDED DIAGNOSIS, 2015, 9414
  • [26] Simulation of dosimetric consequences of 4D-CT-based motion margin estimation for proton radiotherapy using patient tumor motion data
    Koybasi, Ozhan
    Mishra, Pankaj
    James, Sara St.
    Lewis, John H.
    Seco, Joao
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (04) : 853 - 867
  • [27] A model-based 3D patient-specific pre-treatment QA method for VMAT using the EPID
    McCowan, P. M.
    Asuni, G.
    van Beek, T.
    van Uytven, E.
    Kujanpaa, K.
    McCurdy, B. M. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (04) : 1600 - 1612
  • [28] Rehearsals using patient-specific 3D-printed aneurysm models for simulation of endovascular embolization of complex intracranial aneurysms: 3D SIM study
    Le Bras, Anthony
    Boustia, Fakhreddine
    Janot, Kevin
    Le Pabic, Estelle
    Ouvrard, Mathilde
    Fougerou-Leurent, Claire
    Ferre, Jean-Christophe
    Gauvrit, Jean-Yves
    Eugene, Francois
    JOURNAL OF NEURORADIOLOGY, 2023, 50 (01) : 86 - 92
  • [29] Scaled, patient-specific 3D vertebral model reconstruction based on 2D lateral fluoroscopy
    Guoyan Zheng
    Lutz-P. Nolte
    Stephen J. Ferguson
    International Journal of Computer Assisted Radiology and Surgery, 2011, 6 : 351 - 366
  • [30] Clinical Applications of Patient-Specific 3D Printed Models in Cardiovascular Disease: Current Status and Future Directions
    Sun, Zhonghua