Advancing Top-down Analysis of the Human Proteome Using a Benchtop Quadrupole-Orbitrap Mass Spectrometer

被引:72
作者
Fornelli, Luca
Durbin, Kenneth R.
Fellers, Ryan T.
Early, Bryan P.
Greer, Joseph B.
LeDuc, Richard D.
Compton, Philip D.
Kelleher, Neil L. [1 ]
机构
[1] Northwestern Univ, Dept Chem, 2170 Campus Dr, Evanston, IL 60208 USA
基金
美国国家卫生研究院; 瑞士国家科学基金会;
关键词
top-down proteomics; gas-phase fractionation; Orbitrap; quadrupole; data-dependent acquisition; false-discovery rate; mass spectrometry; proteoform; AUTOPILOT; medium/high; GAS-PHASE FRACTIONATION; HIGH-FIELD ORBITRAP; HYDROPHOBIC INTERACTION; ION COALESCENCE; HUMAN-CELLS; IDENTIFICATION; CHROMATOGRAPHY; PROTEOFORMS; SEPARATION; ELECTROPHORESIS;
D O I
10.1021/acs.jproteome.6b00698
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Over the past decade, developments in high resolution mass spectrometry have enabled the high throughput analysis of intact proteins from complex proteomes, leading to the identification of thousands of proteoforms. Several previous reports on top-down proteomics (TDP) relied on hybrid ion trap Fourier transform mass spectrometers combined with data-dependent acquisition strategies. To further reduce TDP to practice, we use a quadrupole-Orbitrap instrument coupled with software for proteoform-dependent data acquisition to identify and characterize nearly 2000 proteoforms at a 1% false discovery rate from human fibroblasts. By combining a 3 m/z isolation window with short transients to improve specificity and signal-to-noise for proteoforms >30 kDa, we demonstrate improving proteome coverage by capturing 439 proteoforms in the 30-60 kDa range. Three different data acquisition strategies were compared and resulted in the identification of many proteoforms not observed in replicate data-dependent experiments. Notably, the data set is reported with updated metrics and tools including a new viewer and assignment of permanent proteoform record identifiers for inclusion of highly characterized proteoforms (i.e., those with C-scores >40) in a repository curated by the Consortium for Top-Down Proteomics.
引用
收藏
页码:609 / 618
页数:10
相关论文
共 50 条
  • [1] Parallel reaction monitoring using quadrupole-Orbitrap mass spectrometer: Principle and applications
    Bourmaud, Adele
    Gallien, Sebastien
    Domon, Bruno
    PROTEOMICS, 2016, 16 (15-16) : 2146 - 2159
  • [2] Advancing Urinary Protein Biomarker Discovery by Data-Independent Acquisition on a Quadrupole-Orbitrap Mass Spectrometer
    Muntel, Jan
    Xuan, Yue
    Berger, Sebastian T.
    Reiter, Lukas
    Bachur, Richard
    Kentsis, Alex
    Steen, Hanno
    JOURNAL OF PROTEOME RESEARCH, 2015, 14 (11) : 4752 - 4762
  • [3] Capillary Zone Electrophoresis-Electron-Capture Collision-Induced Dissociation on a Quadrupole Time-of-Flight Mass Spectrometer for Top-Down Characterization of Intact Proteins
    Shen, Xiaojing
    Xu, Tian
    Hakkila, Blake
    Hare, Mike
    Wang, Qianjie
    Wang, Qianyi
    Beckman, Joseph S.
    Sun, Liangliang
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2021, 32 (06) : 1361 - 1369
  • [4] Targeted N-Glycan Analysis with Parallel Reaction Monitoring Using a Quadrupole-Orbitrap Hybrid Mass Spectrometer
    Cho, Byeong Gwan
    Reyes, Cristian D. Gutierrez
    Goli, Mona
    Gautam, Sakshi
    Banazadeh, Alireza
    Mechref, Yehia
    ANALYTICAL CHEMISTRY, 2022, : 15215 - 15222
  • [5] Development of a GC/Quadrupole-Orbitrap Mass Spectrometer, Part I: Design and Characterization
    Peterson, Amelia C.
    Hauschild, Jan-Peter
    Quarmby, Scott T.
    Krumwiede, Dirk
    Lange, Oliver
    Lemke, Rachelle A. S.
    Grosse-Coosmann, Florian
    Horning, Stevan
    Donohue, Timothy J.
    Westphall, Michael S.
    Coon, Joshua J.
    Griep-Raming, Jens
    ANALYTICAL CHEMISTRY, 2014, 86 (20) : 10036 - 10043
  • [6] Evaluation of the Compact High-Field Orbitrap for Top-Down Proteomics of Human Cells
    Ahlf, Dorothy R.
    Compton, Philip D.
    Tran, John C.
    Early, Bryan P.
    Thomas, Paul M.
    Kelleher, Neil L.
    JOURNAL OF PROTEOME RESEARCH, 2012, 11 (08) : 4308 - 4314
  • [7] UQuantitative analysis of human salivary gland-derived intact proteome using top-down mass spectrometry
    Wu, Si
    Brown, Joseph N.
    Tolic, Nikola
    Meng, Da
    Liu, Xiaowen
    Zhang, Haizhen
    Zhao, Rui
    Moore, Ronald J.
    Pevzner, Pavel
    Smith, Richard D.
    Pasa-Tolic, Ljiljana
    PROTEOMICS, 2014, 14 (10) : 1211 - 1222
  • [8] Development of a GC/Quadrupole-Orbitrap Mass Spectrometer, Part II: New Approaches for Discovery Metabolomics
    Peterson, Amelia C.
    Balloon, Allison J.
    Westphall, Michael S.
    Coon, Joshua J.
    ANALYTICAL CHEMISTRY, 2014, 86 (20) : 10044 - 10051
  • [9] What is Normalization? The Strategies Employed in Top-Down and Bottom-Up Proteome Analysis Workflows
    O'Rourke, Matthew B.
    Town, Stephanie E. L.
    Dalla, Penelope, V
    Bicknell, Fiona
    Belic, Naomi Koh
    Violi, Jake P.
    Steele, Joel R.
    Padula, Matthew P.
    PROTEOMES, 2019, 7 (03) : 1 - 19
  • [10] Robust Analysis of the Yeast Proteome under 50 kDa by Molecular-Mass-Based Fractionation and Top-Down Mass Spectrometry
    Kellie, John F.
    Catherman, Adam D.
    Durbin, Kenneth R.
    Tran, John C.
    Tipton, Jeremiah D.
    Norris, Jeremy L.
    Witkowski, Charles E., II
    Thomas, Paul M.
    Kelleher, Neil L.
    ANALYTICAL CHEMISTRY, 2012, 84 (01) : 209 - 215