共 18 条
Molecularly imprinted polymer for the selective extraction of cocaine and its metabolites, benzoylecgonine and ecgonine methyl ester, from biological fluids before LC-MS analysis
被引:26
作者:
Thibert, Valerie
[1
]
Legeay, Patrice
[1
]
Chapuis-Hugon, Florence
[1
]
Pichon, Valerie
[1
]
机构:
[1] ESPCI ParisTech, Dept Analyt & Bioanalyt Sci & Miniaturizat LSABM, UMR PECSA CNRS UPMC ESPCI ParisTech 7195, F-75231 Paris 05, France
来源:
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
|
2014年
/
949卷
关键词:
Molecularly imprinted polymer;
Selective solid-phase extraction;
Cocaine;
Metabolites;
Plasma;
Urine;
PERFORMANCE LIQUID-CHROMATOGRAPHY;
TANDEM MASS-SPECTROMETRY;
SOLID-PHASE EXTRACTION;
SERUM MICROSAMPLES;
HUMAN URINE;
DRUGS;
PHARMACOKINETICS;
ENVIRONMENT;
SORBENT;
SAMPLES;
D O I:
10.1016/j.jchromb.2013.11.051
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
Considering the important complexity of biological samples, a molecularly imprinted polymer (MIP) was applied to the selective extraction of cocaine and its two main metabolites, benzoylecgonine and ecgonine methyl ester from biological samples. The MIP was imprinted with cocaine and it was synthesized in acetonitrile with methacrylic acid as a functional monomer and ethylene glycol dimethacrylate as a crosslinker. The selectivity of the MIP was first assessed for the three target analytes in acetonitrile with recoveries higher than 80% on the MIP and lower than 30% on the non-imprinted polymer (NIP). The MIP was then evaluated for the selective extraction of these targets from real aqueous media, i.e. serum and urine samples. The pH adjustment of the sample as well as the optimization of the washing step led to a very selective extraction of cocaine from these media. A LOQ of 0.5 ng/mL was obtained for cocaine in urine. Concerning cocaine metabolites, benzoylecgonine and ecgonine methyl ester, they were first extracted from urine by liquid-liquid extraction and the resulting extract was purified on the MIP. The results obtained with the MIP as compared to the LLE alone showed the great potential of the MIP extraction for the clean-up of the biological matrix. This procedure was tested for the extraction of the analytes from urine samples, leading to a very selective protocol with LOQs of 0.09 ng/mL, 0.4 ng/mL and 1.1 ng/mL for cocaine, benzolecgonine and ecgonine methyl ester respectively in urine samples. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:16 / 23
页数:8
相关论文