Modeling, analysis, and modifications of different GT cooling techniques for modern commercial combined cycle power plants with reducing the irreversibility of the HRSG

被引:14
作者
Bassily, A. M. [1 ]
机构
[1] Alexandria Higher Inst Engn & Technol, Alexandria 21311, Egypt
关键词
Gas-steam combined cycle; Improving efficiency; Improving power; M501H GT combined cycle; M501J CT combined cycle; Supplementary fired HRSG; RECOVERY STEAM-GENERATORS; NUMERICAL OPTIMIZATION; DUAL-PRESSURE; GAS-REHEAT; REDUCTION; DESIGN; EFFICIENCY;
D O I
10.1016/j.applthermaleng.2013.01.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
The development of efficient techniques of gas turbine (GT) blade cooling has increased TIT significantly. The mass flow rates of GT cooling fluids increase with increasing TIT and the required flow rate of the cooling steam may exceed the available flow rate as TIT increases beyond 1500 degrees C for the M501H GT combined cycle, mandating the development of a different GT cooling technique that uses less steam for GT blade cooling. Such a cooling technique (steam/air-air GT cooling) applies steam cooling for the first two stages of turbine blade rings (the stationary components only) and was introduced in the development of the M501J GT combined cycle, developed by Mitsubishi Heavy Industries (MHI). In this paper, the steam-cooled combustor and the expansions in the gas turbines that utilize the cooling techniques for modern commercial combined cycle power plants (107H/109H GT, M501H GT, and M501J GT) are presented, modeled, and analyzed. Modifications that enable the M501H GT combined cycle to be operated using the same cooling technique (steam steam air GT cooling) at any given TIT and pressure ratio (r(com)) are presented. Techniques to reduce the irreversibility of the HRSG are introduced, leading to significant improvements in both efficiency and power for all cycles. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:131 / 146
页数:16
相关论文
共 34 条
[1]  
[Anonymous], 2002, SIMPS DUR VENT SIZ H, P6
[2]  
[Anonymous], 2003, 14778 GE POW SYST, V147, P45
[3]   Enhancing the efficiency and power of the triple-pressure reheat combined cycle by means of gas reheat, gas recuperation, and reduction of the irreversibility in the heat recovery steam generator [J].
Bassily, A. M. .
APPLIED ENERGY, 2008, 85 (12) :1141-1162
[4]   Modeling, numerical optimization, and irreversibility reduction of a triple-pressure reheat combined cycle [J].
Bassily, A. M. .
ENERGY, 2007, 32 (05) :778-794
[5]   Modelling, analysis, and irreversibility reduction of the triple-pressure reheat H-system combined cycle [J].
Bassily, A. M. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2006, 220 (A8) :883-898
[6]   Numerical cost optimization and irreversibility analysis of the triple-pressure reheat steam-air cooled GT commercial combined cycle power plants [J].
Bassily, A. M. .
APPLIED THERMAL ENGINEERING, 2012, 40 :145-160
[7]   Cost numerical optimization of the triple-pressure steam-reheat gas-reheat gas-recuperated combined power cycle that uses steam for cooling the first GT [J].
Bassily, A. M. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (15) :1399-1417
[8]   Modeling, numerical optimization, and irreversibility reduction of a dual-pressure reheat combined-cycle [J].
Bassily, AM .
APPLIED ENERGY, 2005, 81 (02) :127-151
[9]   Modelling and numerical optimization of dual- and triple-pressure combined cycles [J].
Bassily, AM .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2004, 218 (A2) :97-109
[10]   Thermoeconomic optimization of heat recovery steam generators operating parameters for combined plants [J].
Casarosa, C ;
Donatini, F ;
Franco, A .
ENERGY, 2004, 29 (03) :389-414