Bilateral near-infrared spectroscopy for detecting traumatic vascular injury

被引:8
|
作者
Van Haren, Robert M. [1 ]
Ryan, Mark L. [1 ]
Thorson, Chad M. [1 ]
Namias, Nicholas [1 ]
Livingstone, Alan S. [1 ]
Proctor, Kenneth G. [1 ]
机构
[1] Univ Miami, Miller Sch Med, Ryder Trauma Ctr, Dewitt Daughtry Family Dept Surg, Miami, FL 33136 USA
关键词
Near-infrared spectroscopy; Vascular injury; Trauma; Battlefield; OXYGEN-SATURATION PREDICTS; COMPARTMENTAL SYNDROME; ARTERIAL TRAUMA; DIAGNOSIS; PRESSURE; SHOCK; ARTERIOGRAPHY; DYSFUNCTION;
D O I
10.1016/j.jss.2013.03.090
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Extremity wounds account for most battlefield injuries. Clinical examination may be unreliable by medics or first responders, and continuous assessment by experienced practitioners may not be possible on the frontline or during transport. Near-infrared spectroscopy (NIRS) provides continuous, noninvasive monitoring of tissue oxygen saturation (StO(2)), but its use is limited by inter-patient and intra-patient variability. We tested the hypothesis that bilateral NIRS partially addresses the variability problem and can reliably identify vascular injury after extremity trauma. Materials and methods: This prospective study consisted of 30 subjects: 20 trauma patients with extremity injury and 10 healthy volunteers. Bilateral StO(2) tissue sensors were placed on the thenar eminence or medial plantar surface. Injured and non-injured extremities within the same patient (DStO(2)) were compared using Wilcoxon signed ranks test. Receiver operating characteristic curves were generated and areas under the curve (AUCs) were calculated for DStO(2) of 6, 10, and 15. Values are expressed as median (interquartile range). Results: Trauma patients were age 31 y (23 y), 85% male, with injury severity score of 9 (5). There were seven arterial and three venous injuries. Most involved the lower extremity (n = 16; 80%) and resulted from a penetrating mechanism (n = 14; 70%). DStO(2) between limbs was 20.4 (10.4) versus 2.4 (3.0) (P < 0.001) for all patients with vascular injury versus patients and volunteers with no vascular injury. DStO(2) reliably identified any vascular injury (AUC, 0.975; P < 0.001), whereas pulse examination alone or in combination with Doppler exam could detect only arterial injury. A DStO(2) of 6 had the greatest sensitivity and specificity (AUC, 0.900; P < 0.001). Conclusions: Continuous monitoring of bilateral limbs with NIRS detects changes in perfusion resulting from arterial or venous injury and may offer advantages over serial manual measurements of pulses or Doppler signals. This technique may be most relevant in military and disaster scenarios or during transport, in which the ability to monitor limb perfusion is difficult or experienced clinical judgment is unavailable. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:526 / 532
页数:7
相关论文
共 50 条
  • [41] The Utility of Near Infrared Spectroscopy in Detecting Intracranial Hemorrhage in Children
    Salonia, Rosanne
    Bell, Michael J.
    Kochanek, Patrick M.
    Berger, Rachel P.
    JOURNAL OF NEUROTRAUMA, 2012, 29 (06) : 1047 - 1053
  • [42] FUNCTIONAL NEAR INFRARED SPECTROSCOPY (FNIRS)-2 NON-INVASIVE METHODS TO ASSESS TRAUMATIC VASCULAR INJURY AFTER TBI
    Amyot, Franck
    Kenney, Kimbra
    Chernomordik, Victor
    Turtzo, L. Christine
    Harburg, Leah
    Moore, Carol
    Spessert, Emily
    Silverman, Erika
    Diaz-Arrastia, Ramon
    JOURNAL OF NEUROTRAUMA, 2015, 32 (12) : A125 - A126
  • [43] Behaviour of near-infrared light in the adult human head: implications for clinical near-infrared spectroscopy
    Young, AER
    Germon, TJ
    Barnett, NJ
    Manara, AR
    Nelson, RJ
    BRITISH JOURNAL OF ANAESTHESIA, 2000, 84 (01) : 38 - 42
  • [44] Cortical tinnitus evaluation using functional near-infrared spectroscopy
    Martins, Mariana Lopes
    Morya, Edgard
    de Lima, Liliane Kaline Araujo
    de Vasconcelos, Isabelle Costa
    Balen, Sheila Andreoli
    Machado, Daniel Gomes da Silva
    da Rosa, Marine Raquel Diniz
    BRAIN RESEARCH, 2025, 1855
  • [45] Continuous monitoring of kidney transplant perfusion with near-infrared spectroscopy
    Malakasioti, Georgia
    Marks, Stephen D.
    Watson, Tom
    Williams, Fariba
    Taylor-Allkins, Mariesa
    Mamode, Nizam
    Morgan, Justin
    Hayes, Wesley N.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2018, 33 (10) : 1863 - 1869
  • [46] Near-infrared spectroscopy: Promising diagnostic tool for viral infections
    Sakudo, A
    Suganuma, Y
    Kobayashi, T
    Onodera, T
    Ikuta, K
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2006, 341 (02) : 279 - 284
  • [47] Near-Infrared Spectroscopy and Aquaphotomics in Cancer Research: A Pilot Study
    Surkova, Anastasiia
    Boichenko, Ekaterina
    Bibikova, Olga
    Artyushenko, Viacheslav
    Muncan, Jelena
    Tsenkova, Roumiana
    JOURNAL OF CHEMOMETRICS, 2024, 38 (12)
  • [48] Near-infrared spectroscopy: bilateral brain monitoring in termed newborns with hypoxic-ischemic lesions
    Mavropulo, T. K.
    Sokolova, K. Y.
    MEDICNI PERSPEKTIVI, 2020, 25 (01): : 157 - 165
  • [49] Evaluation of Cerebral Oxygenation in Neonates with Sepsis with Near-Infrared Spectroscopy
    Rallis, Dimitrios
    Karagianni, Paraskevi
    Milona, Eleni
    Pratsiou, Paraskevi
    Nikolaidis, Nikolaos
    Tsakalidis, Christos
    AMERICAN JOURNAL OF PERINATOLOGY, 2017, 34 (05) : 419 - 427
  • [50] Synergy of Fluorescence and Near-Infrared Spectroscopy in Detection of Colorectal Cancer
    Ehlen, Lukas
    Zabarylo, Urszula J.
    Speichinger, Fiona
    Bogomolov, Andrey
    Belikova, Valerya
    Bibikova, Olga
    Artyushenko, Viacheslav
    Minet, Olaf
    Beyer, Katharina
    Kreis, Martin E.
    Kamphues, Carsten
    JOURNAL OF SURGICAL RESEARCH, 2019, 242 : 349 - 356