Smartphone-based magneto-immunosensor on carbon black modified screen-printed electrodes for point-of-need detection of aflatoxin B1 in cereals

被引:24
|
作者
Jafari, Safiye [1 ,2 ]
Burr, Loic [2 ]
Migliorelli, Davide [2 ]
Galve, Roger [3 ]
Marco, M. Pilar [3 ]
Campbell, Katrina [4 ]
Elliott, Chris [4 ]
Suman, Michele [5 ]
Sturla, Shana J. [1 ]
Generelli, Silvia [2 ]
机构
[1] Swiss Fed Inst Technol, Dept Hlth Sci & Technol, Schmelzbergstr 9, CH-8092 Zurich, Switzerland
[2] Ctr Landquart, CSEM SA, Bahnhofstr 1, CH-7302 Landquart, Switzerland
[3] Inst Adv Chem Catalonia IQAC, Spanish Council Sci Res CS, Nanobiotechnol Diagnost Nb4D, Jordi Girona 18-26, Barcelona 08034, Spain
[4] Queens Univ, Sch Biol Sci, Inst Global Food Secur, 19 Chlorine Gardens, Belfast, North Ireland
[5] Barilla SpA Analyt Food Sci Food Safety & Authent, Parma, Italy
基金
欧盟地平线“2020”;
关键词
Smartphone-based immunosensor; Carbon black; Electrochemical biosensor; Point-of-need detection; Aflatoxin B1; Validation; SENSITIVE DETECTION; BIOSENSOR; PLATFORM; SENSOR; B-1;
D O I
10.1016/j.aca.2022.340118
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Considering the complexities and speed of modern food chains, there is an increasing demand for point-of-need detection of food contaminants, particularly highly regulated chemicals and carcinogens such as aflatoxin B1. We report a user-friendly smartphone-based magneto-immunosensor on carbon black modified electrodes for pointof-need detection of aflatoxin B1 in cereals. For buffered analyte solutions and a corn extract sample, the assay demonstrated a low limit of detection of 13 and 24 pg/mL, respectively. The assay was also highly reproducible, exhibiting mean relative standard deviations of 3.7% and 4.0% for the buffered analyte and corn extract samples. The applicability of the assay was validated on the basis of EU guidelines and the detection capability was lower than or equal to 2 mu g/kg, which is the EU maximum residue limit for aflatoxin B1 in cereals. False-positive and false-negative rates were less than 5%. Additionally, an open-source android application, AflaESense, was designed to provide a simple interface that displays the result in a traffic-light-type format, thus minimizing user training and time for data analysis. AflaESense was used for smartphone-based screening of spiked corn samples containing aflatoxin B1 (0.1, 2, and 10 ng/mL), and naturally contaminated corn containing 0.15 ng aflatoxin B1/mL. The measured values were in close agreement with spiked concentrations (r2 = 0.99), with recovery
引用
收藏
页数:11
相关论文
共 50 条
  • [41] A label-free electrochemiluminescence immunosensor based on silver nanoparticle hybridized mesoporous carbon for the detection of Aflatoxin B1
    Lv, Xiaohui
    Li, Yuyang
    Cao, Wei
    Yan, Tao
    Li, Yueyun
    Du, Bin
    Wei, Qin
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 202 : 53 - 59
  • [42] Using low-cost disposable immunosensor based on flexible PET screen-printed electrode modified with carbon black and gold nanoparticles for sensitive detection of SARS-CoV-2
    Ferreira, Luis M. C.
    Reis, Isabela F.
    Martins, Paulo R.
    Marcolino-Junior, Luiz H.
    Bergamini, Marcio F.
    Camargo, Jessica R.
    Janegitz, Bruno C.
    Vicentini, Fernando C.
    TALANTA OPEN, 2023, 7
  • [43] Rapid Quantitative Detection of Brucella melitensis by a Label-Free Impedance Immunosensor Based on a Gold Nanoparticle-Modified Screen-Printed Carbon Electrode
    Wu, Haiyun
    Zuo, Yueming
    Cui, Chuanjin
    Yang, Wei
    Ma, Haili
    Wang, Xiaowen
    SENSORS, 2013, 13 (07): : 8551 - 8563
  • [44] Ionic liquid-enhanced silica aerogels for the specific extraction and detection of aflatoxin B1 coupled with a smartphone-based colorimetric biosensor
    Jiang, Wenpeng
    Yang, Qingli
    Duo, Huixiao
    Wu, Wei
    Hou, Xiudan
    FOOD CHEMISTRY, 2024, 447
  • [45] Multiwalled carbon nanotube modified screen-printed electrodes for the detection of p-aminophenol:: Optimisation and application in alkaline phosphatase-based assays
    Lamas-Ardisana, Pedro Jose
    Queipo, Paula
    Fanjul-Bolado, Pablo
    Costa-Garcia, Agustin
    ANALYTICA CHIMICA ACTA, 2008, 615 (01) : 30 - 38
  • [46] A Disposable Electrochemical Biosensor Based on Screen-Printed Carbon Electrodes Modified with Silver Nanowires/HPMC/Chitosan/Urease for the Detection of Mercury (II) in Water
    Saenchoopa, Apichart
    Klangphukhiew, Supannika
    Somsub, Rachata
    Talodthaisong, Chanon
    Patramanon, Rina
    Daduang, Jureerut
    Daduang, Sakda
    Kulchat, Sirinan
    BIOSENSORS-BASEL, 2021, 11 (10):
  • [47] Design of a new electrochemical aptasensor based on screen printed carbon electrode modified with gold nanoparticles for the detection of fumonisin B1 in maize flour
    Behnaz Naghshbandi
    Mohsen Adabi
    Kamran Pooshang Bagheri
    Hamid Tavakolipour
    Journal of Nanobiotechnology, 20
  • [48] Design of a new electrochemical aptasensor based on screen printed carbon electrode modified with gold nanoparticles for the detection of fumonisin B1 in maize flour
    Naghshbandi, Behnaz
    Adabi, Mohsen
    Bagheri, Kamran Pooshang
    Tavakolipour, Hamid
    JOURNAL OF NANOBIOTECHNOLOGY, 2023, 20 (01)
  • [49] A disposable amperometric immunosensor for α-1-fetoprotein based on enzyme-labeled antibody/chitosan-membrane-modified screen-printed carbon electrode
    Yu, H
    Yan, F
    Dai, Z
    Ju, HX
    ANALYTICAL BIOCHEMISTRY, 2004, 331 (01) : 98 - 105
  • [50] A disposable label-free electrochemiluminescent immunosensor for transferrin detection based on a luminol-reduced gold nanoparticle-modified screen-printed carbon electrode
    Kong, Weijun
    Zhou, He
    Ouyang, Hui
    Li, Zongyun
    Fu, Zhifeng
    ANALYTICAL METHODS, 2014, 6 (09) : 2959 - 2964