Smartphone-based magneto-immunosensor on carbon black modified screen-printed electrodes for point-of-need detection of aflatoxin B1 in cereals

被引:24
|
作者
Jafari, Safiye [1 ,2 ]
Burr, Loic [2 ]
Migliorelli, Davide [2 ]
Galve, Roger [3 ]
Marco, M. Pilar [3 ]
Campbell, Katrina [4 ]
Elliott, Chris [4 ]
Suman, Michele [5 ]
Sturla, Shana J. [1 ]
Generelli, Silvia [2 ]
机构
[1] Swiss Fed Inst Technol, Dept Hlth Sci & Technol, Schmelzbergstr 9, CH-8092 Zurich, Switzerland
[2] Ctr Landquart, CSEM SA, Bahnhofstr 1, CH-7302 Landquart, Switzerland
[3] Inst Adv Chem Catalonia IQAC, Spanish Council Sci Res CS, Nanobiotechnol Diagnost Nb4D, Jordi Girona 18-26, Barcelona 08034, Spain
[4] Queens Univ, Sch Biol Sci, Inst Global Food Secur, 19 Chlorine Gardens, Belfast, North Ireland
[5] Barilla SpA Analyt Food Sci Food Safety & Authent, Parma, Italy
基金
欧盟地平线“2020”;
关键词
Smartphone-based immunosensor; Carbon black; Electrochemical biosensor; Point-of-need detection; Aflatoxin B1; Validation; SENSITIVE DETECTION; BIOSENSOR; PLATFORM; SENSOR; B-1;
D O I
10.1016/j.aca.2022.340118
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Considering the complexities and speed of modern food chains, there is an increasing demand for point-of-need detection of food contaminants, particularly highly regulated chemicals and carcinogens such as aflatoxin B1. We report a user-friendly smartphone-based magneto-immunosensor on carbon black modified electrodes for pointof-need detection of aflatoxin B1 in cereals. For buffered analyte solutions and a corn extract sample, the assay demonstrated a low limit of detection of 13 and 24 pg/mL, respectively. The assay was also highly reproducible, exhibiting mean relative standard deviations of 3.7% and 4.0% for the buffered analyte and corn extract samples. The applicability of the assay was validated on the basis of EU guidelines and the detection capability was lower than or equal to 2 mu g/kg, which is the EU maximum residue limit for aflatoxin B1 in cereals. False-positive and false-negative rates were less than 5%. Additionally, an open-source android application, AflaESense, was designed to provide a simple interface that displays the result in a traffic-light-type format, thus minimizing user training and time for data analysis. AflaESense was used for smartphone-based screening of spiked corn samples containing aflatoxin B1 (0.1, 2, and 10 ng/mL), and naturally contaminated corn containing 0.15 ng aflatoxin B1/mL. The measured values were in close agreement with spiked concentrations (r2 = 0.99), with recovery
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Aptasensor Based on Screen-Printed Carbon Electrodes Modified with CS/AuNPs for Sensitive Detection of Okadaic Acid in Shellfish
    Ni Zeng
    Xinyi Wang
    Yiyang Dong
    Yan Yang
    Yingai Yin
    Lianhui Zhao
    Xu Wang
    Journal of Analysis and Testing, 2023, 7 (02) : 128 - 135
  • [22] Aptasensor Based on Screen-Printed Carbon Electrodes Modified with CS/AuNPs for Sensitive Detection of Okadaic Acid in Shellfish
    Ni Zeng
    Xinyi Wang
    Yiyang Dong
    Yan Yang
    Yingai Yin
    Lianhui Zhao
    Xu Wang
    Journal of Analysis and Testing, 2023, 7 : 128 - 135
  • [23] Aptasensor Based on Screen-Printed Carbon Electrodes Modified with CS/AuNPs for Sensitive Detection of Okadaic Acid in Shellfish
    Zeng, Ni
    Wang, Xinyi
    Dong, Yiyang
    Yang, Yan
    Yin, Yingai
    Zhao, Lianhui
    Wang, Xu
    JOURNAL OF ANALYSIS AND TESTING, 2023, 7 (02) : 128 - 135
  • [24] A novel immunosensor based on cobalt oxide nanocomposite modified single walled carbon nanohorns for the selective detection of aflatoxin B1
    Damphathik, Chulalak
    Songsiriritthigul, Chomphunuch
    Lerdsri, Jamras
    Jakmunee, Jaroon
    Wongnongwa, Yutthana
    Jungsuttiwong, Siriporn
    Ortner, Astrid
    Kalcher, Kurt
    Samphao, Anchalee
    TALANTA, 2023, 258
  • [25] Amperometric immunosensor for the determination of ceruloplasmin in human serum and urine based on covalent binding to carbon nanotubes-modified screen-printed electrodes
    Garcinuno, B.
    Ojeda, I.
    Moreno-Guzman, M.
    Gonzalez-Cortes, A.
    Yanez-Sedeno, P.
    Pingarron, J. M.
    TALANTA, 2014, 118 : 61 - 67
  • [26] Point-of-Care Detection of Carcinoembryonic Antigen (CEA) Using a Smartphone-Based, Label-Free Electrochemical Immunosensor with Multilayer CuONPs/CNTs/GO on a Disposable Screen-Printed Electrode
    Khonyoung, Supada
    Mangkronkaew, Praphatsorn
    Klayprasert, Puttaporn
    Puangpila, Chanida
    Palanisami, Muthukumaran
    Arivazhagan, Mani
    Jakmunee, Jaroon
    Biosensors, 2024, 14 (12):
  • [27] Development of a smartphone-based biomimetic sensor for aflatoxin B1 detection using molecularly imprinted polymer membranes
    Sergeyev, Tetyana
    Yarynka, Dania
    Piletska, Elena
    Linnik, Rostyslav
    Zaporozhets, Olga
    Brovko, Oleksandr
    Piletsky, Sergey
    El'skaya, Anna
    TALANTA, 2019, 201 : 204 - 210
  • [28] Silver Nanoparticles Coupled with Graphene Nanoplatelets Modified Screen-Printed Carbon Electrodes for Rhodamine B Detection in Food Products
    Kartika, Andi Eka
    Setiyanto, Henry
    Manurung, Robeth Viktoria
    Jenie, Siti Nurul Aisyiyah
    Saraswaty, Vienna
    ACS OMEGA, 2021, 6 (47): : 31477 - 31484
  • [29] Laccase biosensor based on screen-printed electrode modified with thionine-carbon black nanocomposite, for Bisphenol A detection
    Portaccio, M.
    Di Tuoro, D.
    Arduini, F.
    Moscone, D.
    Cammarota, M.
    Mita, D. G.
    Lepore, M.
    ELECTROCHIMICA ACTA, 2013, 109 : 340 - 347
  • [30] Rapid and sensitive point-of-need aflatoxin B1 testing in feedstuffs using a smartphone-powered mobile microfluidic lab-on-fiber device
    Zhuo, Yuxin
    Xu, Wenjuan
    Chen, Yuan
    Long, Feng
    JOURNAL OF HAZARDOUS MATERIALS, 2023, 460