Smartphone-based magneto-immunosensor on carbon black modified screen-printed electrodes for point-of-need detection of aflatoxin B1 in cereals

被引:24
|
作者
Jafari, Safiye [1 ,2 ]
Burr, Loic [2 ]
Migliorelli, Davide [2 ]
Galve, Roger [3 ]
Marco, M. Pilar [3 ]
Campbell, Katrina [4 ]
Elliott, Chris [4 ]
Suman, Michele [5 ]
Sturla, Shana J. [1 ]
Generelli, Silvia [2 ]
机构
[1] Swiss Fed Inst Technol, Dept Hlth Sci & Technol, Schmelzbergstr 9, CH-8092 Zurich, Switzerland
[2] Ctr Landquart, CSEM SA, Bahnhofstr 1, CH-7302 Landquart, Switzerland
[3] Inst Adv Chem Catalonia IQAC, Spanish Council Sci Res CS, Nanobiotechnol Diagnost Nb4D, Jordi Girona 18-26, Barcelona 08034, Spain
[4] Queens Univ, Sch Biol Sci, Inst Global Food Secur, 19 Chlorine Gardens, Belfast, North Ireland
[5] Barilla SpA Analyt Food Sci Food Safety & Authent, Parma, Italy
基金
欧盟地平线“2020”;
关键词
Smartphone-based immunosensor; Carbon black; Electrochemical biosensor; Point-of-need detection; Aflatoxin B1; Validation; SENSITIVE DETECTION; BIOSENSOR; PLATFORM; SENSOR; B-1;
D O I
10.1016/j.aca.2022.340118
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Considering the complexities and speed of modern food chains, there is an increasing demand for point-of-need detection of food contaminants, particularly highly regulated chemicals and carcinogens such as aflatoxin B1. We report a user-friendly smartphone-based magneto-immunosensor on carbon black modified electrodes for pointof-need detection of aflatoxin B1 in cereals. For buffered analyte solutions and a corn extract sample, the assay demonstrated a low limit of detection of 13 and 24 pg/mL, respectively. The assay was also highly reproducible, exhibiting mean relative standard deviations of 3.7% and 4.0% for the buffered analyte and corn extract samples. The applicability of the assay was validated on the basis of EU guidelines and the detection capability was lower than or equal to 2 mu g/kg, which is the EU maximum residue limit for aflatoxin B1 in cereals. False-positive and false-negative rates were less than 5%. Additionally, an open-source android application, AflaESense, was designed to provide a simple interface that displays the result in a traffic-light-type format, thus minimizing user training and time for data analysis. AflaESense was used for smartphone-based screening of spiked corn samples containing aflatoxin B1 (0.1, 2, and 10 ng/mL), and naturally contaminated corn containing 0.15 ng aflatoxin B1/mL. The measured values were in close agreement with spiked concentrations (r2 = 0.99), with recovery
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Ultrasensitive Immunosensor for Aflatoxin B1 Detection Based on Screen-Printed Carbon Electrode Modified by Ferrocene@Multi-Walled Carbon Nanotubes
    Zhang, Hui
    Shi, Zhaoqiang
    Cheng, Shuting
    Yang, Qingqing
    Sun, Xia
    Guo, Yemin
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (09): : 9170 - 9180
  • [2] Sensitive Electrochemical Immunosensor for Detection of Mycotoxins Aflatoxin B1 Using Disposable screen-Printed Carbon Electrode
    Liu, Ping
    Qi, Xingpu
    Zhang, Huanxin
    Zheng, Yi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (03): : 1 - 11
  • [3] Studies towards the development of a screen-printed carbon electrochemical immunosensor array for mycotoxins:: A sensor for aflatoxin B1
    Pemberton, R. M.
    Pittson, R.
    Biddle, N.
    Drago, G. A.
    Hart, J. P.
    ANALYTICAL LETTERS, 2006, 39 (08) : 1573 - 1586
  • [4] Electrochemical immunosensor array using a 96-well screen-printed microplate for aflatoxin B1 detection
    Piermarini, S.
    Micheli, L.
    Ammida, N. H. S.
    Palleschi, G.
    Moscone, D.
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (07): : 1434 - 1440
  • [5] Smartphone-based square wave voltammetry system with screen-printed graphene electrodes for norepinephrine detection
    Ji D.
    Shi Z.
    Liu Z.
    Low S.S.
    Zhu J.
    Zhang T.
    Chen Z.
    Yu X.
    Lu Y.
    Lu D.
    Liu Q.
    Liu, Qingjun (qjliu@zju.edu.cn), 1600, KeAi Communications Co. (01): : 1 - 9
  • [6] Smartphone-based electrochemical potentiostat detection system using pedot: Pss/chitosan/graphene modified screen-printed electrodes for dopamine detection
    Shen, Xiaoyan
    Ju, Feng
    Li, Guicai
    Ma, Lei
    Sensors (Switzerland), 2020, 20 (10):
  • [7] A disposable electrochemical immunosensor based on carbon screen-printed electrodes for the detection of prostate specific antigen
    Yan, Mei
    Zang, Dejin
    Ge, Shenguang
    Ge, Lei
    Yu, Jinghua
    BIOSENSORS & BIOELECTRONICS, 2012, 38 (01): : 355 - 361
  • [8] Smartphone-Based Electrochemical Potentiostat Detection System Using PEDOT: PSS/Chitosan/Graphene Modified Screen-Printed Electrodes for Dopamine Detection
    Shen, Xiaoyan
    Ju, Feng
    Li, Guicai
    Ma, Lei
    SENSORS, 2020, 20 (10)
  • [9] Smartphone-based electrochemical system with multi-walled carbon nanotubes/thionine/gold nanoparticles modified screen-printed immunosensor for cancer antigen 125 detection
    Fan, Yan
    Shi, Shengyu
    Ma, Junshuang
    Guo, Yaohua
    MICROCHEMICAL JOURNAL, 2022, 174
  • [10] Smartphone-based cyclic voltammetry system with graphene modified screen printed electrodes for glucose detection
    Ji, Daizong
    Liu, Lei
    Li, Shuang
    Chen, Chen
    Lu, Yanli
    Wu, Jiajia
    Liu, Qingjun