A novel electrochemical sensor for non-ergoline dopamine agonist pramipexole based on electrochemically reduced graphene oxide nanoribbons

被引:18
|
作者
Narayana, Prashanth S. [1 ]
Teradal, Nagappa L. [1 ]
Seetharamappa, J. [1 ]
Satpati, Ashis K. [2 ]
机构
[1] Karnatak Univ, Dept Chem, Dharwad 580003, Karnataka, India
[2] Bhabha Atom Res Ctr, Analyt Chem Div, Bombay 400085, Maharashtra, India
关键词
POTENTIAL SWEEP VOLTAMMOGRAM; GENERAL EXPRESSION; TOXICITY; STATE;
D O I
10.1039/c5ay00282f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A facile and feasible electrochemical sensing platform based on electrochemically reduced graphene oxide nanoribbons (ERGONRs) was designed for electrochemical investigations and determination of a non-ergoline dopamine agonist, pramipexole dihydrochloride monohydrate (PPX), in pharmaceutical formulations and biological fluids. Newly synthesized graphene oxide nanoribbons were characterized by SEM, AFM, XRD and EDX. The solution of graphene oxide nanoribbons (GONRs) was placed on a glassy carbon electrode (GCE) and reduced electrochemically in phosphate buffer solution of pH 6 to obtain the electrochemically reduced graphene oxide nanoribbon modified glassy carbon electrode (ERGONR-GCE). Significant electrooxidation of PPX was observed at the ERGONR-GCE in phosphate buffer of pH 6.0 compared to that at the bare GCE. The effect of accumulation time, pH and scan rate was studied and various electrochemical parameters were evaluated. The plot of pH versus E-p yielded a slope of 57.65 mV per pH in the pH range of 3.0-8.0 indicating the participation of an equal number of electrons and protons in the electrode process. A differential pulse voltammetric method was developed for the determination of PPX in bulk, pharmaceutical formulations and urine samples. PPX showed a linear relationship between the peak current and the concentration in the range of 0.01-15 mu M with a LOD of 2.8 nM and a LOQ of 9.4 nM. The fabricated electrode also showed good selectivity and excellent sensitivity. The proposed method is simple, rapid and inexpensive and hence could be readily adopted for the analysis of PPX. The results were subjected to statistical analysis.
引用
收藏
页码:3912 / 3919
页数:8
相关论文
共 50 条
  • [1] A novel electrochemical sensor for non-ergoline dopamine agonist pramipexole based on electrochemically reduced graphene oxide nanoribbons
    Department of Chemistry, Karnatak University, Dharwad
    580 003, India
    不详
    400 085, India
    Anal. Methods, 9 (3912-3919):
  • [2] An electrochemical sensor for dopamine based on poly(o-phenylenediamine) functionalized with electrochemically reduced graphene oxide
    Liu, Xuexia
    Zhu, Hui
    Yang, Xiurong
    RSC ADVANCES, 2014, 4 (08): : 3706 - 3712
  • [3] A novel electrochemical sensor based on thermally reduced graphene oxide for the sensitive determination of dopamine
    Gaidukevic, Justina
    Aukstakojyte, Ruta
    Barkauskas, Jurgis
    Niaura, Gediminas
    Murauskas, Tomas
    Pauliukaite, Rasa
    APPLIED SURFACE SCIENCE, 2022, 592
  • [4] Electrochemical Sensors Based on Electrochemically Reduced Graphene Oxide
    Rao Honghong
    Xue Zhonghua
    Wang Xuemei
    Zhao Guohu
    Hou Huihui
    Wang Hui
    PROGRESS IN CHEMISTRY, 2016, 28 (2-3) : 337 - 352
  • [5] Electrochemical Sensor Based on Reduced Graphene Oxide Nanoribbons for the Determination of Baicalein in Urine Samples
    Tandel, Ranjita D.
    Naik, Roopa S.
    Seetharamappa, J.
    Satpati, Ashis K.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (12) : II818 - II827
  • [6] A sensitive electrochemical sensor based on polypyrrole/electrochemically reduced graphene oxide for the determination of imidacloprid
    Chen, Chenglong
    Han, Zhen
    Lei, Wu
    Ding, Yong
    Lv, Jingjing
    Xia, Mingzhu
    Wang, Fengyun
    Hao, Qingli
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2019, 9 (03): : 143 - 152
  • [7] Efficacy, safety, and tolerance of the non-ergoline dopamine agonist pramipexole in the treatment of advanced Parkinson's disease: a double blind, placebo controlled, randomised, multicentre study
    Pinter, MM
    Pogarell, O
    Oertel, WH
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1999, 66 (04): : 436 - 441
  • [8] A novel electrochemical sensor based on FeS anchored reduced graphene oxide nanosheets for simultaneous determination of dopamine and acetaminophen
    Liu, Xiaoya
    Shangguan, Enbo
    Li, Jing
    Ning, Sashuang
    Guo, Litan
    Li, Quanmin
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 70 : 628 - 636
  • [9] Hydrophilic graphene surface prepared by electrochemically reduced micellar graphene oxide as a platform for electrochemical sensor
    Akkarachanchainon, Nontapol
    Rattanawaleedirojn, Pranee
    Chailapakul, Orawon
    Rodthongkum, Nadnudda
    TALANTA, 2017, 165 : 692 - 701
  • [10] Enzymatic glucose biosensor based on bismuth nanoribbons electrochemically deposited on reduced graphene oxide
    Devasenathipathy, Rajkumar
    Karthik, Raj
    Chen, Shen-Ming
    Ali, Mohammad Ajmal
    Mani, Veerappan
    Lou, Bih-Show
    Al-Hemaid, Fahad Mohammed Abdullrahman
    MICROCHIMICA ACTA, 2015, 182 (13-14) : 2165 - 2172