Optimizing non-Pb radiation shielding materials using bilayers

被引:76
作者
McCaffrey, J. P. [1 ]
Mainegra-Hing, E. [1 ]
Shen, H. [1 ]
机构
[1] Natl Res Council Canada, Inst Natl Measurement Stand, Ottawa, ON K1A 0R6, Canada
关键词
unleaded protective clothing; radiation shielding; x-ray attenuation; shielding weight; bilayer; CARDIAC-CATHETERIZATION PROCEDURES; LEAD; APRONS; EXPOSURE; SIMULATIONS; ATTENUATION; PROTECTION; RADIOLOGY;
D O I
10.1118/1.3260839
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The objective of this study was to demonstrate that the weight of non-Pb radiation shielding materials can be minimized by structuring the material as a bilayer composed of different metal-powder-embedded elastomer layers. Methods: Measurements and Monte Carlo (MC) calculations were performed to study the attenuation properties of several non-Pb metal bilayers over the x-ray energy range 30-150 keV. Metals for the layers were chosen on the basis of low cost, nontoxicity, and complementary photoelectric absorption characteristics. The EGSnrc user code cavity.cpp was used to calculate the resultant x-ray fluence spectra after attenuation by these metal layers. Air kerma attenuation was measured using commercially manufactured metal/elastomer test layers. These layers were irradiated using the primary standard calibration beams at the Institute for National Measurement Standards in Ottawa, Canada utilizing the six x-ray beam qualities recommended in the German Standard DIN 6857. Both the measurements and the calculations were designed to approximate surface irradiation as well as penetrating radiation at 10 mm depth in soft tissue. The MC modeling point and the position of the measurement detector for surface irradiation were both directly against the downstream face of the attenuating material, as recommended in DIN 6857. Results: The low-Z upstream/high-Z downstream ordering of the metal bilayers provided substantially more attenuation than the reverse order. Optimal percentages of each metal in each bilayer were determined for each x-ray radiation beam quality. Conclusions: Depending on the x-ray quality, appropriate choices of two complementary metal-embedded elastomer layers can decrease the weight of radiation shielding garments by up to 25% compared to Pb-based elastomer garments while providing equivalent attenuation. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3260839]
引用
收藏
页码:5586 / 5594
页数:9
相关论文
共 25 条
[1]  
Attix F H, 1986, INTRO RADIOLOGICAL P
[2]   Evaluation of the transmitted exposure through lead equivalent aprons used in a radiology department, including the contribution from backscatter [J].
Christodoulou, EG ;
Goodsitt, MM ;
Larson, SC ;
Darner, KL ;
Satti, J ;
Chan, HP .
MEDICAL PHYSICS, 2003, 30 (06) :1033-1038
[3]  
DIN Deutsches Institut fur Normung e. V, 2009, 68571200901 DIN
[4]  
*I PHYS ENG MED, 1997, 78 IPEM
[5]   Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version [J].
Kawrakow, I .
MEDICAL PHYSICS, 2000, 27 (03) :485-498
[6]  
Kawrakow I, 2003, Tech. Rep. PIRS-701
[7]  
KAWRAKOW I, 2005, 898 PIRS NAT RES COU
[8]   EFFECTIVENESS OF LEAD APRONS IN VASCULAR RADIOLOGY - RESULTS OF CLINICAL MEASUREMENTS [J].
KICKEN, PJ ;
BOS, AJJ .
RADIOLOGY, 1995, 197 (02) :473-478
[9]   Occupational radiation doses to operators performing cardiac catheterization procedures [J].
Kim, Kwang Pyo ;
Miller, Donald L. ;
Balter, Stephen ;
Kleinerman, Ruth A. ;
Linet, Martha S. ;
Kwon, Deukwoo ;
Simon, Steven L. .
HEALTH PHYSICS, 2008, 94 (03) :211-227
[10]   Minimising radiation exposure to physicians performing fluoroscopically guided cardiac catheterisation procedures: a review [J].
Kim, Kwang Pyo ;
Miller, Donald L. .
RADIATION PROTECTION DOSIMETRY, 2009, 133 (04) :227-233