Semi-automatic bowel wall thickness measurements on MR enterography in patients with Crohn's disease

被引:21
作者
Naziroglu, Robiel E. [1 ]
Puylaert, Carl A. J. [2 ]
Tielbeek, Jeroen A. W. [2 ]
Makanyanga, Jesica [3 ]
Menys, Alex [3 ]
Ponsioen, Cyriel Y. [2 ]
Hatzakis, Haralambos [4 ]
Taylor, Stuart A. [3 ]
Stoker, Jaap [2 ]
van Vliet, Lucas J. [1 ]
Vos, Frans M. [1 ,2 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Delft, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Radiol, Amsterdam, Netherlands
[3] UCL, Ctr Med Imaging, London, England
[4] Biotronics3D Inc, London, England
关键词
MAGNETIC-RESONANCE; AUTOMATIC DETECTION; CAPSULE ENDOSCOPY; SEGMENTATION; ENTEROCLYSIS; DIAGNOSIS; SEVERITY;
D O I
10.1259/bjr.20160654
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate a semi-automatic method for delineation of the bowel wall and measurement of the wall thickness in patients with Crohn's disease. Methods: 53 patients with suspected or proven Crohn's disease were selected. Two radiologists independently supervised the delineation of regions with active Crohn's disease on MRI, yielding manual annotations (Ano1, Ano2). Three observers manually measured the maximal bowel wall thickness of each annotated segment. An active contour segmentation approach semi-automatically delineated the bowel wall. For each active region, two segmentations (Seg1, Seg2) were obtained by independent observers, in which the maximum wall thickness was automatically determined. The overlap between (Seg1, Seg2) was compared with the overlap of (Ano1, Ano2) using Wilcoxon's signed rank test. The corresponding variances were compared using the Brown-Forsythe test. The variance of the semi-automatic thickness measurements was compared with the overall variance of manual measurements through an F-test. Furthermore, the intraclass correlation coefficient (ICC) of semiautomatic thickness measurements was compared with the ICC of manual measurements through a likelihood-ratio test. Results: Patient demographics: median age, 30 years; interquartile range, 25-38 years; 33 females. The median overlap of the semi-automatic segmentations (Seg1 vs Seg2: 0.89) was significantly larger than the median overlap of the manual annotations (Ano1 vs Ano2: 0.72); p = 1.4 x 10(-5). The variance in overlap of the semiautomatic segmentations was significantly smaller than the variance in overlap of the manual annotations (p = 1.1 x 10(-9)). The variance of the semi-automated measurements (0.46 mm(2)) was significantly smaller than the variance of the manual measurements (2.90 mm(2), p = 1.1 x 10(-7)). The ICC of semi-automatic measurement (0.88) was significantly higher than the ICC of manual measurement (0.45); p = 50.005. Conclusion: The semi-automatic technique facilitates reproducible delineation of regions with active Crohn's disease. The semi-automatic thickness measurement sustains significantly improved interobserver agreement. Advances in knowledge: Automation of bowel wall thickness measurements strongly increases reproducibility of these measurements, which are commonly used in MRI scoring systems of Crohn's disease activity.
引用
收藏
页数:11
相关论文
共 30 条
[1]   Diagnosis of small bowel Crohn's disease:: a prospective comparison of capsule endoscopy with magnetic resonance imaging and fluoroscopic enteroclysis [J].
Albert, JG ;
Martiny, F ;
Krummenerl, A ;
Stock, K ;
Lesske, J ;
Göbel, CM ;
Lotterer, E ;
Nietsch, HH ;
Behrmann, C ;
Fleig, WE .
GUT, 2005, 54 (12) :1721-1727
[2]   Automatic Detection and Segmentation of Lymph Nodes From CT Data [J].
Barbu, Adrian ;
Suehling, Michael ;
Xu, Xun ;
Liu, David ;
Zhou, S. Kevin ;
Comaniciu, Dorin .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (02) :240-250
[3]  
Bhushan M, 2011, LECT NOTES COMPUT SC, V6891, P476, DOI 10.1007/978-3-642-23623-5_60
[4]   Diffusion-weighted magnetic resonance imaging for detecting and assessing ileal inflammation in Crohn's disease [J].
Buisson, A. ;
Joubert, A. ;
Montoriol, P-F ;
Ines, D. D. ;
Hordonneau, C. ;
Pereira, B. ;
Garcier, J-M ;
Bommelaer, G. ;
Petitcolin, V. .
ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2013, 37 (05) :537-545
[5]   Geodesic active contours [J].
Caselles, V ;
Kimmel, R ;
Sapiro, G .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1997, 22 (01) :61-79
[6]   Regression forests for efficient anatomy detection and localization in computed tomography scans [J].
Criminisi, A. ;
Robertson, D. ;
Konukoglu, E. ;
Shotton, J. ;
Pathak, S. ;
White, S. ;
Siddiqui, K. .
MEDICAL IMAGE ANALYSIS, 2013, 17 (08) :1293-1303
[7]   MEASURES OF THE AMOUNT OF ECOLOGIC ASSOCIATION BETWEEN SPECIES [J].
DICE, LR .
ECOLOGY, 1945, 26 (03) :297-302
[8]   Imaging of small intestinal Crohn's disease: comparison between MR enteroclysis and conventional enteroclysis [J].
Gourtsoyiannis, Nicholas C. ;
Grammatikakis, John ;
Papamastorakis, George ;
Koutroumbakis, John ;
Prassopoulos, Panos ;
Rousomoustakaki, Maria ;
Papanikolaou, Nickolas .
EUROPEAN RADIOLOGY, 2006, 16 (09) :1915-1925
[9]   A Probabilistic Method for Estimation of Bowel Wall Thickness in MR Colonography [J].
Hampshire, Thomas ;
Menys, Alex ;
Jaffer, Asif ;
Bhatnagar, Gauraang ;
Punwani, Shonit ;
Atkinson, David ;
Halligan, Steve ;
Hawkes, David J. ;
Taylor, Stuart A. .
PLOS ONE, 2017, 12 (01)
[10]   Diffusion-Weighted Magnetic Resonance Imaging in Ileocolonic Crohn's Disease: Validation of Quantitative Index of Activity [J].
Hordonneau, C. ;
Buisson, A. ;
Scanzi, J. ;
Goutorbe, F. ;
Pereira, B. ;
Borderon, C. ;
Da Ines, D. ;
Montoriol, P. F. ;
Garcier, J. M. ;
Boyer, L. ;
Bommelaer, G. ;
Petitcolin, V. .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2014, 109 (01) :89-98