Technical Note: Induced radioactivity in stereotactic body radiation therapy with a flattening-filter-free 10 MV beam model

被引:1
|
作者
Wang, Huidong [1 ]
Chen, Kunzhi [1 ]
Shi, Yinghua [1 ]
Huang, Xiaolong [2 ]
Sun, Wuji [3 ]
Hou, Kairan [3 ]
Jin, Yongli [2 ]
Jiang, Xin [1 ]
Yang, Dong [3 ]
Dong, Lihua [1 ,4 ]
机构
[1] First Hosp Jilin Univ, Dept Radiat Oncol & Therapy, Changchun, Peoples R China
[2] China Inst Atom Energy, Beijing, Peoples R China
[3] Jilin Univ, Coll Phys, Changchun, Peoples R China
[4] First Hosp Jilin Univ, Jilin Prov Key Lab Radiat Oncol & Therapy, Changchun, Peoples R China
基金
中国国家自然科学基金;
关键词
flattening‐ filter‐ free; induced radioactivity; stereotactic body radiation therapy; MEDICAL LINEAR ACCELERATORS; HEALTH-PHYSICS ASPECTS; MODULATED ARC THERAPY; ROOM ENTRY TIMES; ACTIVATION PROCESSES; NEUTRON-PRODUCTION; NUCLEAR-REACTIONS; RADIOTHERAPY; SECONDARY; PROTECTION;
D O I
10.1002/mp.14747
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The induced radioactivity in stereotactic body radiation therapy with a flattening-filter-free 10 MV beam model (10 FFF SBRT) was investigated for the risk to therapists. Methods This study was performed on a Varian TrueBeam linac. The induced radioisotopes were identified by gamma spectroscopy. The dose rate from the induced activity was measured for 12 treatment cycles in 4 h continuously. The impacts of the characteristic factors of 10 FFF SBRT on the dose rate were investigated, including monitor units (MU), beam rate, field size, and flattening filter. The dose rate was compared between the SBRT plans and conventional fractionation plans. A mathematical model was used to analyze the results and estimate the annual dose to therapists. Results (a) The induced radioisotopes included Na-24, Al-28, Cl-38, Mn-56, Cu-66, W-187, and Au-196. (b) In 4 h, the total dose contribution ratios were more than 70% for Al-28, about 20% for Mn-56, and 10% for all other long-lived radioisotopes, combining doses at the isocenter and end of the treatment couch. (c) The dose rate showed a nonlinear growth with increasing MU and beam rate. The variation of the dose rate was complicated with the jaw field and not sensitive to the MLC field. The removal of the flattening filter reduced the dose rate by about 40%. The dose level of SBRT was two to three times that of conventional fractionation. (d) The estimated annual dose to therapists was up to 0.20 mSv/y. Conclusions The induced radioactivity in 10 FFF SBRT was higher compared with that in 10 MV conventional fractionation. More MU and higher beam rate were the primary factors that caused the increase. The therapists should wait longer after beam-off to reduce the occupational dose. In addition, aluminum and manganese should be less used in the treatment room.
引用
收藏
页码:2010 / 2017
页数:8
相关论文
共 27 条
  • [21] Stereotactic ablative radiation therapy for brain metastases with volumetric modulated arc therapy and flattening filter free delivery: feasibility and early clinical results
    Fiorentino, Alba
    Giaj-Levra, Niccolo
    Tebano, Umberto
    Mazzola, Rosario
    Ricchetti, Francesco
    Fersino, Sergio
    Di Paola, Gioacchino
    Aiello, Dario
    Ruggieri, Ruggero
    Alongi, Filippo
    RADIOLOGIA MEDICA, 2017, 122 (09): : 676 - 682
  • [22] Stereotactic ablative radiation therapy for brain metastases with volumetric modulated arc therapy and flattening filter free delivery: feasibility and early clinical results
    Alba Fiorentino
    Niccolò Giaj-Levra
    Umberto Tebano
    Rosario Mazzola
    Francesco Ricchetti
    Sergio Fersino
    Gioacchino Di Paola
    Dario Aiello
    Ruggero Ruggieri
    Filippo Alongi
    La radiologia medica, 2017, 122 : 676 - 682
  • [23] Breathing-motion induced interplay effects for stereotactic body radiotherapy of liver tumours using flattening-filter free volumetric modulated arc therapy
    Edvardsson, A.
    Scherman, J.
    Nilsson, M. P.
    Wennberg, B.
    Nordstrom, F.
    Ceberg, C.
    Ceberg, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (02)
  • [24] Volumetric modulated arc therapy with flattening filter free (FFF) beams for stereotactic body radiation therapy (SBRT) in patients with medically inoperable early stage non small cell lung cancer (NSCLC)
    Navarria, Pierina
    Ascolese, Anna Maria
    Mancosu, Pietro
    Alongi, Filippo
    Clerici, Elena
    Tozzi, Angelo
    Iftode, Cristina
    Reggiori, Giacomo
    Tomatis, Stefano
    Infante, Maurizio
    Alloisio, Marco
    Testori, Alberto
    Fogliata, Antonella
    Cozzi, Luca
    Morenghi, Emanuela
    Scorsetti, Marta
    RADIOTHERAPY AND ONCOLOGY, 2013, 107 (03) : 414 - 418
  • [25] Stereotactic body radiation therapy (SBRT) for lung malignancies: preliminary toxicity results using a flattening filter-free linear accelerator operating at 2400 monitor units per minute
    Prendergast, Brendan M.
    Dobelbower, Michael C.
    Bonner, James A.
    Popple, Richard A.
    Baden, Craig J.
    Minnich, Douglas J.
    Cerfolio, Robert J.
    Spencer, Sharon A.
    Fiveash, John B.
    RADIATION ONCOLOGY, 2013, 8
  • [26] A mouse radiation-induced liver disease model for stereotactic body radiation therapy validated in patients with hepatocellular carcinoma
    Wu, Zhi-Feng
    Zhang, Jian-Ying
    Shen, Xiao-Yun
    Zhou, Le-Yuan
    Gao, Ya-Bo
    Hu, Yong
    Zeng, Zhao-Chong
    MEDICAL PHYSICS, 2016, 43 (07) : 4349 - 4361
  • [27] Technical Note: Comparison of the internal target volume (ITV) contours and dose calculations on 4DCT, average CBCT, and 4DCBCT imaging for lung stereotactic body radiation therapy (SBRT)
    Dumas, Michael
    Laugeman, Eric
    Sevak, Parag
    Snyder, Karen C.
    Mao, Weihua
    Chetty, Indrin J.
    Ajlouni, Munther
    Wen, Ning
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (11): : 288 - 294