Technical Note: Induced radioactivity in stereotactic body radiation therapy with a flattening-filter-free 10 MV beam model

被引:1
|
作者
Wang, Huidong [1 ]
Chen, Kunzhi [1 ]
Shi, Yinghua [1 ]
Huang, Xiaolong [2 ]
Sun, Wuji [3 ]
Hou, Kairan [3 ]
Jin, Yongli [2 ]
Jiang, Xin [1 ]
Yang, Dong [3 ]
Dong, Lihua [1 ,4 ]
机构
[1] First Hosp Jilin Univ, Dept Radiat Oncol & Therapy, Changchun, Peoples R China
[2] China Inst Atom Energy, Beijing, Peoples R China
[3] Jilin Univ, Coll Phys, Changchun, Peoples R China
[4] First Hosp Jilin Univ, Jilin Prov Key Lab Radiat Oncol & Therapy, Changchun, Peoples R China
基金
中国国家自然科学基金;
关键词
flattening‐ filter‐ free; induced radioactivity; stereotactic body radiation therapy; MEDICAL LINEAR ACCELERATORS; HEALTH-PHYSICS ASPECTS; MODULATED ARC THERAPY; ROOM ENTRY TIMES; ACTIVATION PROCESSES; NEUTRON-PRODUCTION; NUCLEAR-REACTIONS; RADIOTHERAPY; SECONDARY; PROTECTION;
D O I
10.1002/mp.14747
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The induced radioactivity in stereotactic body radiation therapy with a flattening-filter-free 10 MV beam model (10 FFF SBRT) was investigated for the risk to therapists. Methods This study was performed on a Varian TrueBeam linac. The induced radioisotopes were identified by gamma spectroscopy. The dose rate from the induced activity was measured for 12 treatment cycles in 4 h continuously. The impacts of the characteristic factors of 10 FFF SBRT on the dose rate were investigated, including monitor units (MU), beam rate, field size, and flattening filter. The dose rate was compared between the SBRT plans and conventional fractionation plans. A mathematical model was used to analyze the results and estimate the annual dose to therapists. Results (a) The induced radioisotopes included Na-24, Al-28, Cl-38, Mn-56, Cu-66, W-187, and Au-196. (b) In 4 h, the total dose contribution ratios were more than 70% for Al-28, about 20% for Mn-56, and 10% for all other long-lived radioisotopes, combining doses at the isocenter and end of the treatment couch. (c) The dose rate showed a nonlinear growth with increasing MU and beam rate. The variation of the dose rate was complicated with the jaw field and not sensitive to the MLC field. The removal of the flattening filter reduced the dose rate by about 40%. The dose level of SBRT was two to three times that of conventional fractionation. (d) The estimated annual dose to therapists was up to 0.20 mSv/y. Conclusions The induced radioactivity in 10 FFF SBRT was higher compared with that in 10 MV conventional fractionation. More MU and higher beam rate were the primary factors that caused the increase. The therapists should wait longer after beam-off to reduce the occupational dose. In addition, aluminum and manganese should be less used in the treatment room.
引用
收藏
页码:2010 / 2017
页数:8
相关论文
共 27 条
  • [1] Efficacy of flattening-filter-free beam in stereotactic body radiation therapy planning and treatment: A systematic review with meta-analysis
    Dang, Thu M.
    Peters, Mitchell J.
    Hickey, Brigid
    Semciw, Adam
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2017, 61 (03) : 379 - 387
  • [2] Stereotactic body radiation therapy for liver tumours using flattening filter free beam: dosimetric and technical considerations
    Mancosu, Pietro
    Castiglioni, Simona
    Reggiori, Giacomo
    Catalano, Maddalena
    Alongi, Filippo
    Pellegrini, Chiara
    Arcangeli, Stefano
    Tozzi, Angelo
    Lobefalo, Francesca
    Fogliata, Antonella
    Navarria, Piera
    Cozzi, Luca
    Scorsetti, Marta
    RADIATION ONCOLOGY, 2012, 7
  • [3] Dosimetric comparison of a 6-MV flattening-filter and a flattening-filter-free beam for lung stereotactic ablative radiotherapy treatment
    Kim, Yon-Lae
    Chung, Jin-Beom
    Kim, Jae-Sung
    Lee, Jeong-Woo
    Kim, Jin-Young
    Kang, Sang-Won
    Suh, Tae-Suk
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (09) : 1672 - 1678
  • [4] Flattening Filter Free vs. Flattened Beams for Lung Stereotactic Body Radiation Therapy
    Annede, Pierre
    Darreon, Julien
    Benkemouche, Ahcene
    Valdenaire, Simon
    Tyran, Marguerite
    Kaeppelin, Bertrand
    Macagno, Alban
    Barrou, Julien
    Cagetti, Leonel Varela
    Favrel, Veronique
    Moureau-Zabotto, Laurence
    Gonzague, Laurence
    Fau, Pierre
    Chargari, Cyrus
    Tallet, Agnes
    Salem, Naji
    ANTICANCER RESEARCH, 2017, 37 (09) : 5133 - 5139
  • [5] Effects of 10 MV and Flattening-Filter-Free Beams on Peripheral Dose in a Cohort of Pediatric Patients
    Ben Bouchta, Youssef
    Goddard, Karen
    Petric, M. Peter
    Bergman, Alanah M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (05): : 1560 - 1568
  • [6] Stereotactic body radiation therapy for prostate cancer: a dosimetric comparison of IMRT and VMAT using flattening filter and flattening filter-free beams
    El-Sayed, Sherif M.
    El-Gebaly, Reem H.
    Fathy, Mohamed M.
    Abdelaziz, Dina M.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024, 63 (03) : 423 - 431
  • [7] Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique
    Miura, Hideharu
    Ozawa, Shuichi
    Doi, Yoshiko
    Nakao, Minoru
    Kubo, Katsumaro
    Kenjo, Masahiko
    Nagata, Yasushi
    JOURNAL OF RADIATION RESEARCH, 2020, 61 (04) : 575 - 585
  • [8] A dosimetric and treatment efficiency evaluation of stereotactic body radiation therapy for peripheral lung cancer using flattening filter free beams
    Zhang, Ji-Yong
    Lu, Jia-Yang
    Wu, Li-Li
    Hong, Dan-Li
    Ma, Chang-chun
    Peng, Xun
    Lin, Zhi-Xiong
    ONCOTARGET, 2016, 7 (45) : 73792 - 73799
  • [9] Flattening filter free stereotactic body radiation therapy for lung tumors: outcomes and predictive factors
    Jaruthien, Thitiporn
    Kitpanit, Sarin
    Kannarunimit, Danita
    Nantavithya, Chonnipa
    Prayongrat, Anussara
    Alisanant, Petch
    Saksornchai, Kitwadee
    Amornwichet, Napapat
    Raiyava, Tassapong
    Chakkabat, Chakkapong
    Lertbutsayanukul, Chawalit
    Khorprasert, Chonlakiet
    Shotelersuk, Kanjana
    TRANSLATIONAL CANCER RESEARCH, 2021, 10 (02) : 571 - 580
  • [10] Flattening filter-free linac improves treatment delivery efficiency in stereotactic body radiation therapy
    Prendergast, Brendan M.
    Fiveash, John B.
    Popple, Richard A.
    Clark, Grant M.
    Thomas, Evan M.
    Minnich, Douglas J.
    Jacob, Rojymon
    Spencer, Sharon A.
    Bonner, James A.
    Dobelbower, Michael C.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (03): : 64 - 71