Preliminary pilot plant tests of a corona discharge-electron beam hybrid combustion flue gas cleaning system

被引:49
作者
Chang, JS
Looy, PC
Nagai, K
Yoshioka, T
Aoki, S
Maezawa, A
机构
[1] EBARA RES CO,FUJISAWA,KANAGAWA 251,JAPAN
[2] EBARA CO,TOKYO 108,JAPAN
关键词
D O I
10.1109/28.485824
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Pilot plant tests of a corona discharge-electron beam hybrid combustion flow gas cleaning system have been conducted. Gas flow rate of the test loop is a heavy oil fired boiler flue gas with 1200 Nm(3)/h, and one electron beam generator (500 kV x 30 mA) is used with a corona discharge ammonia radical injection system (60 kV x 5 mA). SO2, CO, CO2, NH3, NO, NOx, and O-2 gases are monitored. The results show that up to 85% of NOx and 98% of SOx in flue gases are removed under a corona discharge-electron beam hybrid operations with significant small amount of leaked ammonias from exhaust flue gases.
引用
收藏
页码:131 / 137
页数:7
相关论文
共 20 条
[2]  
CHANG JS, 1988, IEEE IND APPL SOC 19, P1645
[3]  
CHANG JS, 1993, 1993 IEEE IAS M, P1969
[4]  
CHANG JS, 1994, NONTHERMAL PLASMA TE, P1
[5]  
CHANG JS, 1986, AEROSOL FORMATION RE, P867
[6]  
CHANG JS, 1991, IEEE T PLASMA SCI, V19, P1102
[7]   COMBINED REMOVAL OF SO2, NOX, AND FLY-ASH FROM SIMULATED FLUE-GAS USING PULSED STREAMER CORONA [J].
CLEMENTS, JS ;
MIZUNO, A ;
FINNEY, WC ;
DAVIS, RH .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1989, 25 (01) :62-69
[8]   INDUSTRIAL EXPERIMENTS ON PULSE CORONA SIMULTANEOUS REMOVAL OF NOX AND SO2 FROM FLUE-GAS [J].
DINELLI, G ;
CIVITANO, L ;
REA, M .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1990, 26 (03) :535-541
[9]  
HIGASHI M, 1991, T IEE JAPAN A, V111, P457
[10]  
JORDAN S, 1988, J AEROSOL SCI, V17, P669